  • The ADLINK TB‑16P8R/12 is a compact, panel‑mountable terminal board designed to provide 16 optically isolated digital input channels and 8 relay output channels. It serves as an interface between field‑level devices and ADLINK’s digital I/O cards or modules, offering electrical isolation, signal conditioning, and convenient screw‑terminal connectivity. The board is part of ADLINK’s TB‑series terminal boards, which include models such as TB‑24P, TB‑24R, and DIN‑24 variants for various I/O configurations.
- Dual‑Function I/O Board: Combines 16 opto‑isolated digital inputs and 8 relay outputs on a single compact panel.
- Electrical Isolation: Each input channel is optically isolated up to 2500 V DC, protecting host systems from voltage transients and ground loops.
- Relay Output Section: Eight SPDT (Single‑Pole Double‑Throw) miniature relays provide flexible switching for AC or DC loads.
- LED Status Indicators: 24 LEDs (green, yellow, red) provide real‑time visual indication of input and output channel states.
- Wide Input Range: Accepts logic‑high voltages from 3 V DC to 24 V DC or currents from 6 mA to 50 mA, allowing direct connection to a variety of sensors and logic devices.
- 12 V Relay Coil Voltage: The TB‑16P8R/12 variant uses 12 V DC relay coils (model DSIE‑S‑DC12V). A 24 V version (TB‑16P8R/24) is also available.
- Opto‑22 Compatibility: Equipped with a 50‑pin Opto‑22‑compatible connector (CN6) for direct connection to ADLINK NuDAQ and NuDAM I/O cards such as ACL‑7122, PET‑48DIO, PCI‑7248, and PCI‑7296.
- Screw‑Terminal Connectivity: Two × 16‑pin input terminals and two × 12‑pin output terminals provide secure field wiring.
- Compact Form Factor: Panel dimensions 220 mm × 132 mm × 15 mm enable easy integration into control cabinets or test benches.
- Status Display: 24 LEDs arranged by port (A, B, C) correspond to channel groups for intuitive monitoring.
- High Reliability: Designed for industrial environments with surge‑withstand miniature relays and robust PCB construction.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8473 3020 000

Comprehensive Product Summary – ADLINK TB‑16P8R/12 Isolated 16 DI / 8 DO Relay 12 V Panel




### 1. Product Overview

Product Name: TB‑16P8R/12
Article Number: TB‑16P8R/12
Series: TB‑xxP/xxR Terminal Board Series
Manufacturer: ADLINK Technology Inc.
Product Type: Isolated 16 Digital Inputs (DI) and 8 Relay Outputs (DO) Terminal Board
Revision Reference: Manual Rev 2.30 (April 12, 2000)
Manufacturer Address: 9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan, R.O.C.
Manufacturer Website: [www.adlink.com.tw](http://www.adlink.com.tw)

The ADLINK TB‑16P8R/12 is a compact, panel‑mountable terminal board designed to provide 16 optically isolated digital input channels and 8 relay output channels. It serves as an interface between field‑level devices and ADLINK’s digital I/O cards or modules, offering electrical isolation, signal conditioning, and convenient screw‑terminal connectivity. The board is part of ADLINK’s TB‑series terminal boards, which include models such as TB‑24P, TB‑24R, and DIN‑24 variants for various I/O configurations.




### 2. Key Features

- Dual‑Function I/O Board: Combines 16 opto‑isolated digital inputs and 8 relay outputs on a single compact panel.
- Electrical Isolation: Each input channel is optically isolated up to 2500 V DC, protecting host systems from voltage transients and ground loops.
- Relay Output Section: Eight SPDT (Single‑Pole Double‑Throw) miniature relays provide flexible switching for AC or DC loads.
- LED Status Indicators: 24 LEDs (green, yellow, red) provide real‑time visual indication of input and output channel states.
- Wide Input Range: Accepts logic‑high voltages from 3 V DC to 24 V DC or currents from 6 mA to 50 mA, allowing direct connection to a variety of sensors and logic devices.
- 12 V Relay Coil Voltage: The TB‑16P8R/12 variant uses 12 V DC relay coils (model DSIE‑S‑DC12V). A 24 V version (TB‑16P8R/24) is also available.
- Opto‑22 Compatibility: Equipped with a 50‑pin Opto‑22‑compatible connector (CN6) for direct connection to ADLINK NuDAQ and NuDAM I/O cards such as ACL‑7122, PET‑48DIO, PCI‑7248, and PCI‑7296.
- Screw‑Terminal Connectivity: Two × 16‑pin input terminals and two × 12‑pin output terminals provide secure field wiring.
- Compact Form Factor: Panel dimensions 220 mm × 132 mm × 15 mm enable easy integration into control cabinets or test benches.
- Status Display: 24 LEDs arranged by port (A, B, C) correspond to channel groups for intuitive monitoring.
- High Reliability: Designed for industrial environments with surge‑withstand miniature relays and robust PCB construction.




### 3. Technical Specifications

General Characteristics
- Model: TB‑16P8R/12
- Function: 16 Opto‑Isolated Digital Inputs + 8 Relay Outputs
- Isolation Voltage: 2500 V DC (optical isolation between field and logic circuits)
- Relay Coil Voltage: 12 V DC
- Relay Type: High‑sensitivity miniature relay, 1500 V FCC surge withstanding
- Relay Form: SPDT (Single Pole Double Throw)

Input Section
- Number of Channels: 16 (optically isolated)
- Logic Input Low Voltage: < 0.8 V DC
- Logic Input High Voltage: +3 V DC to +24 V DC
- Logic Input Current: 6.3 mA to 50 mA
- Logic “1”: Voltage input high
- Logic “0”: Voltage input low
- Isolation: 2500 V DC (photo‑coupler isolation)

Output Section
- Number of Channels: 8 relay outputs
- Contact Rating:
- Max Switching Power: 60 W / 125 VA
- Max Switching Voltage: 220 V DC / 250 V AC
- Max Switching Current: 2 A DC or AC
- Max Carrying Current: 3 A DC or AC
- UL/CSA Ratings: 0.6 A @ 125 V AC, 0.6 A @ 110 V DC, 2 A @ 30 V DC
- Relay Coil Type: DSIE‑S‑DC12V (for TB‑16P8R/12)

Indicators
- LED Count: 24 (16 for inputs + 8 for outputs)
- LED Colors: Green (Port A), Yellow (Port B), Red (Port C)
- Logic Definition: Logic “1” = LED ON; Logic “0” = LED OFF

Connectors
- CN1, CN2: Input terminal blocks (16 channels total)
- CN3, CN4: Output terminal blocks (8 relay channels total)
- CN5: Power input (+12 V DC and GND)
- CN6: 50‑pin Opto‑22 compatible connector for I/O interface

Physical Characteristics
- Dimensions: 220 mm (W) × 132 mm (D) × 15 mm (H)
- Weight: Approx. 0.4 kg (typical)
- Mounting: Panel mount with screw holes
- Material: FR‑4 PCB with solder mask and silkscreen




### 4. Functionality

The TB‑16P8R/12 acts as an interface board between field devices and ADLINK digital I/O cards. It provides electrical isolation for input signals and relay switching for output control.

Operation Principle
- Input Channels: Each input signal is fed through a photo‑coupler (opto‑isolator) that transfers the signal to the logic side without direct electrical connection. This protects the host system from voltage spikes and ground potential differences.
- Output Channels: Each relay output is driven by a control signal from the connected I/O card through the Opto‑22 interface. The relay contacts can switch external loads such as solenoids, lamps, or contactors.
- LED Indicators: Each channel has a dedicated LED that illuminates when the channel is active, providing instant visual feedback for diagnostics and monitoring.

Typical Applications
- Industrial automation and process control systems
- Machine status monitoring and signal isolation
- Relay control for motors, valves, and actuators
- Data acquisition and test systems requiring isolated I/O
- Interface between PLC logic levels and field devices

Compatibility
- Fully compatible with ADLINK NuDAQ and NuDAM series I/O cards and modules.
- Opto‑22 standard 50‑pin connector ensures interoperability with ACL‑7122, ACL‑7124, PET‑48DIO, PCI‑7248, PCI‑7296, and similar boards.
- Can be used with external power supplies providing regulated +12 V DC for relay operation.




### 5. Components & Accessories

Included Components
- TB‑16P8R/12 terminal board assembly
- 24 status LEDs (pre‑installed)
- Screw terminal blocks for inputs and outputs
- 50‑pin Opto‑22 connector (CN6)
- Power input connector (CN5)

Optional Accessories
- ACL‑10150‑1.5 Flat Cable (1.5 m): 50‑pin ribbon cable for connecting to ADLINK I/O cards (not included by default).
- Mounting Hardware: Panel screws and standoffs for cabinet installation.
- External Power Supply: Regulated +12 V DC supply for relay coil operation.

Connectors and Pin Assignments
- CN1/CN2 (Input Terminals): Each channel has two pins (+ and –) for signal and return.
- CN3/CN4 (Output Terminals): Each relay channel has three pins – Common (COM), Normally Closed (NC), and Normally Open (NO).
- CN5 (Power Input): +12 V and GND for relay coil supply.
- CN6 (Opto‑22 Connector): 50‑pin header providing Port A (relay outputs) and Ports B & C (opto‑isolated inputs).




### 6. Installation & Setup

Power Requirements
- Supply Voltage: +12 V DC regulated
- Power Consumption: Dependent on relay activation (approx. 0.5 A max with all relays energized)

Mounting Options
- Designed for panel mount installation using screw holes on the PCB edges.
- Can be mounted inside control cabinets or test racks.

Connection Procedure
1. Connect the +12 V DC power supply to CN5 (+12 V and GND).
2. Wire input devices (sensors, switches) to CN1 and CN2 terminals according to channel assignments.
3. Wire output loads to CN3 and CN4 terminals (COM, NC, NO contacts).
4. Connect the 50‑pin flat cable (ACL‑10150‑1.5 or equivalent) from CN6 to the corresponding I/O card connector.
5. Verify LED indications for proper operation after power‑up.

Configuration Notes
- Input jumpers (JP8–JP23) can be set for dry‑contact or photo‑coupler operation modes.
- Ensure the I/O card is configured in Mode 7 for proper communication with the TB‑16P8R.
- Observe polarity when connecting DC inputs and power supply.




### 7. Performance & Capabilities

Input Performance
- Fast response time due to solid‑state photo‑couplers.
- High noise immunity and galvanic isolation for industrial environments.
- Supports a wide range of input voltages (3–24 V DC) and currents (6–50 mA).

Output Performance
- Relays rated for up to 250 V AC or 220 V DC switching.
- Capable of handling up to 2 A switching current and 3 A carrying current.
- Mechanical relay response time typically < 10 ms.
- Contact life expectancy > 100,000 operations at rated load.

Efficiency and Reliability
- Opto‑isolation minimizes ground loop currents and signal interference.
- Relays with FCC surge withstanding design ensure long‑term durability.
- LED indicators simplify troubleshooting and reduce downtime.

Limitations
- Mechanical relays are not suited for high‑frequency switching applications.
- Requires external 12 V DC supply for relay operation.
- Not intended for direct connection to high‑voltage mains without proper isolation and safety measures.




### 8. Standards & Compliance

- Electrical Isolation: 2500 V DC tested between input and logic circuits.
- Relay Safety Ratings: UL and CSA compliant contact ratings (0.6 A @ 125 V AC, 2 A @ 30 V DC).
- Surge Withstand: 1500 V FCC surge resistance for relay coils.
- Connector Standard: Opto‑22 compatible 50‑pin header interface.
- Manufacturing Quality: Designed and tested to ADLINK industrial standards for reliability and safety.
- RoHS Status: Not specified in original manual (refer to current ADLINK documentation for updated compliance).




### 9. Additional Information

Warranty
- Duration: 1 year from date of purchase.
- Coverage: Free from defects in materials and workmanship.
- Exclusions: Damage from misuse, modification, or operation beyond specifications.
- Remedy: Repair or replacement at manufacturer’s discretion upon written notice.
- Return Policy: Equipment must be returned postage‑prepaid and securely packaged.

Support & Service Contacts
- Sales & Service: service@adlink.com.tw
- Technical Support (NuDAQ): nudaq@adlink.com.tw
- Software Support: sw@adlink.com.tw
- Telephone: +886‑2‑82265877
- Fax: +886‑2‑82265717

Maintenance & Care
- Periodically inspect terminal connections for tightness and corrosion.
- Avoid exposure to excessive dust, moisture, or vibration.
- Replace relays only with identical rated models (DSIE‑S‑DC12V).
- Ensure proper ventilation to prevent heat buildup in enclosed installations.

Firmware / Hardware Updates
- The TB‑16P8R/12 is a passive hardware interface board and does not require firmware updates.
- Compatibility updates may be available through ADLINK for newer I/O cards or software drivers.

Related Products in the Series
- TB‑24P: 24 Opto‑Isolated Digital Inputs Terminal Board
- TB‑24R: 24 Relay Outputs Terminal Board
- DIN‑24P: DIN‑mount 24 Opto‑Isolated Inputs Board
- DIN‑24R: DIN‑mount 24 Relay Outputs Board
- DIN‑24G: 24‑Position I/O Module Rack Board




### Summary

The ADLINK TB‑16P8R/12 is a versatile and robust terminal board that integrates 16 optically isolated digital inputs and 8 relay outputs into a single compact unit. Its combination of photo‑coupler input isolation and relay output switching makes it ideal for industrial automation, machine control, and data acquisition applications where signal integrity and system protection are critical. The board’s Opto‑22 compatible interface ensures seamless integration with ADLINK NuDAQ and NuDAM I/O cards, while its LED status indicators and screw‑terminal connections simplify installation and maintenance. With a 12 V relay coil design, 2500 V isolation, and UL/CSA‑rated contacts, the TB‑16P8R/12 delivers industrial‑grade performance and reliability for a wide range of control and monitoring tasks.