- Thermocouple Type T Input: Designed for copper-constantan thermocouples, offering high accuracy and stability over the specified temperature range.
- Input Range: -100°C to +400°C, covering a broad span suitable for low- to medium-temperature industrial and laboratory processes.
- Output Signal: 0–5 V DC linearized output, compatible with most analog input systems.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion across the entire range.
- Galvanic Isolation: Provides 1500 V RMS isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- High Accuracy and Stability: Typical accuracy better than ±0.1% of full scale, with low drift over time and temperature.
- Compact Modular Design: Standard 5B form factor for use in backplanes or DIN-rail carriers, enabling flexible system configuration.
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes and data acquisition systems.
- Low Power Consumption: Designed for efficient operation in multi-channel systems.
- Rugged Industrial Construction: Encapsulated module for protection against vibration, humidity, and electrical interference.
- Input Range: -100°C to +400°C, covering a broad span suitable for low- to medium-temperature industrial and laboratory processes.
- Output Signal: 0–5 V DC linearized output, compatible with most analog input systems.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion across the entire range.
- Galvanic Isolation: Provides 1500 V RMS isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- High Accuracy and Stability: Typical accuracy better than ±0.1% of full scale, with low drift over time and temperature.
- Compact Modular Design: Standard 5B form factor for use in backplanes or DIN-rail carriers, enabling flexible system configuration.
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes and data acquisition systems.
- Low Power Consumption: Designed for efficient operation in multi-channel systems.
- Rugged Industrial Construction: Encapsulated module for protection against vibration, humidity, and electrical interference.
1. Product Overview
Name: 5B47-T06
Model: 5B47-T06
Series: 5B Series Signal Conditioning Modules
Article Number: 5B47-T06
Manufacturer: (Typically produced by Analog Devices / Measurement Computing or compatible 5B module manufacturers)
The 5B47-T06 is a precision signal conditioning module designed for thermocouple type T (copper-constantan) temperature measurement applications. It belongs to the 5B Series of modular, isolated analog signal conditioners widely used in industrial, laboratory, and process control environments. The module provides a linearized, isolated, and amplified analog output proportional to the thermocouple input signal. Specifically, it converts a Type T thermocouple input range of -100°C to +400°C into a standardized 0–5 V analog output, suitable for direct interface with data acquisition systems, PLCs, and analog input cards.
2. Key Features
- Thermocouple Type T Input: Designed for copper-constantan thermocouples, offering high accuracy and stability over the specified temperature range.
- Input Range: -100°C to +400°C, covering a broad span suitable for low- to medium-temperature industrial and laboratory processes.
- Output Signal: 0–5 V DC linearized output, compatible with most analog input systems.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion across the entire range.
- Galvanic Isolation: Provides 1500 V RMS isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- High Accuracy and Stability: Typical accuracy better than ±0.1% of full scale, with low drift over time and temperature.
- Compact Modular Design: Standard 5B form factor for use in backplanes or DIN-rail carriers, enabling flexible system configuration.
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes and data acquisition systems.
- Low Power Consumption: Designed for efficient operation in multi-channel systems.
- Rugged Industrial Construction: Encapsulated module for protection against vibration, humidity, and electrical interference.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | 5B47-T06 |
| Input Type | Thermocouple Type T (Copper-Constantan) |
| Input Range | -100°C to +400°C |
| Output Range | 0 to +5 V DC |
| Output Impedance | < 1 Ω |
| Input Impedance | > 10 MΩ |
| Accuracy | ±0.1% of full scale typical |
| Linearity Error | ±0.05% of full scale |
| Isolation Voltage | 1500 V RMS (input-to-output and power-to-output) |
| Common Mode Rejection (CMR) | > 100 dB at 50/60 Hz |
| Bandwidth | Typically 3 Hz (low-pass filtered for noise reduction) |
| Response Time | 100 ms typical to 90% of final value |
| Temperature Coefficient | ±0.01%/°C of full scale |
| Power Supply Voltage | +5 V DC nominal (from backplane) |
| Power Consumption | Approximately 25 mW typical |
| Operating Temperature Range | -40°C to +85°C |
| Storage Temperature Range | -55°C to +100°C |
| Relative Humidity | 0–95% non-condensing |
| Dimensions | Approx. 60 mm (L) × 52 mm (W) × 12.5 mm (H) |
| Weight | Approx. 45 g |
| Mounting | Plug-in module for 5B backplane or DIN-rail carrier |
| Material | Molded thermoplastic housing, epoxy encapsulated electronics |
4. Functionality
The 5B47-T06 operates as a precision thermocouple signal conditioner. It accepts a low-level millivolt signal from a Type T thermocouple and performs several key functions internally:
1. Cold-Junction Compensation (CJC): The module measures the ambient temperature at the input terminals and compensates for the thermocouple’s cold junction, ensuring accurate absolute temperature readings.
2. Amplification: The small thermocouple voltage (typically in the microvolt range) is amplified to a standard 0–5 V output signal.
3. Linearization: The nonlinear thermocouple response is corrected using internal circuitry, providing a linear voltage output proportional to temperature.
4. Isolation: Input, output, and power circuits are galvanically isolated, preventing ground loops and protecting connected equipment.
5. Filtering: Internal low-pass filtering minimizes noise and interference from industrial environments.
Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement systems
- Environmental test chambers
- Data acquisition systems (DAQ)
- PLC analog input expansion
- HVAC and refrigeration monitoring
- Energy management and thermal profiling
Compatibility:
The module is compatible with all standard 5B backplanes, carriers, and data acquisition systems supporting 0–5 V analog inputs. It can interface directly with A/D converters, controllers, and monitoring software.
5. Components & Accessories
Included Items:
- 5B47-T06 signal conditioning module
- Integrated cold-junction compensation sensor
- Factory calibration and test documentation
Optional Accessories:
- 5B01, 5B02, 5B03, or 5B08 backplanes (for multi-channel installations)
- 5B Series DIN-rail mounting kits
- Shielded thermocouple input cables
- Terminal blocks and screw connectors for thermocouple wiring
- Protective covers and labeling kits
Connectors:
- Input: Screw terminal or plug-in connector for thermocouple leads (copper-constantan)
- Output: 0–5 V analog output via backplane connector
- Power: Supplied through backplane bus (+5 V DC)
6. Installation & Setup
Requirements:
- Compatible 5B backplane or carrier with +5 V DC supply
- Proper thermocouple wiring (Type T, copper-constantan)
- Stable ambient conditions for accurate cold-junction compensation
Mounting Options:
- Plug directly into a 5B backplane slot
- Mount on DIN rail using a 5B Series carrier
- Ensure adequate spacing for ventilation and access
Configuration Steps:
1. Insert the 5B47-T06 module into the designated backplane slot.
2. Connect the Type T thermocouple leads to the input terminals, observing correct polarity.
3. Connect the backplane output to the data acquisition or control system analog input.
4. Power the backplane with +5 V DC.
5. Verify output scaling: 0 V corresponds to -100°C, 5 V corresponds to +400°C.
6. Perform system calibration if required by the application.
Environmental Considerations:
- Avoid exposure to excessive vibration or moisture.
- Maintain ambient temperature within the specified operating range.
- Ensure thermocouple junctions are properly shielded from electrical noise sources.
7. Performance & Capabilities
The 5B47-T06 delivers high-precision, stable, and noise-immune temperature measurement performance.
Speed:
- Response time of approximately 100 ms ensures near real-time temperature tracking for most process control applications.
Capacity:
- Each module handles one thermocouple input channel; multiple modules can be combined in a backplane for multi-channel systems.
Efficiency:
- Low power consumption (<25 mW) allows dense channel configurations without excessive heat buildup.
Accuracy and Stability:
- Factory-calibrated for ±0.1% full-scale accuracy.
- Excellent long-term stability with minimal drift.
- High common-mode rejection (>100 dB) ensures reliable operation in electrically noisy environments.
Limitations:
- Designed specifically for Type T thermocouples; not suitable for other thermocouple types without corresponding module variants (e.g., 5B47-K for Type K).
- Output limited to 0–5 V range; systems requiring 0–10 V or 4–20 mA outputs require additional signal conditioning.
- Bandwidth limited to a few hertz, optimized for temperature signals rather than fast-changing inputs.
8. Standards & Compliance
The 5B47-T06 complies with relevant industrial and safety standards for signal conditioning modules:
- Electrical Isolation: 1500 V RMS per ANSI/ISA and IEC standards for reinforced isolation.
- EMC Compliance: Designed to meet EN 61326-1 (Industrial Environment) for electromagnetic compatibility.
- Safety Standards: Conforms to UL, CE, and CSA requirements for low-voltage and industrial control equipment.
- RoHS Compliance: Fully compliant with the Restriction of Hazardous Substances Directive (RoHS 2011/65/EU).
- Temperature Measurement Standards: Calibrated according to ITS-90 thermocouple reference tables for Type T.
- Quality Assurance: Manufactured under ISO 9001-certified quality management systems.
9. Additional Information
Warranty:
Typically supplied with a 1-year limited warranty covering defects in materials and workmanship under normal operating conditions. Extended warranty options may be available depending on the distributor or manufacturer.
Support:
Technical support includes application notes, wiring diagrams, and calibration procedures. Manufacturer and authorized distributors provide assistance for integration with data acquisition systems and troubleshooting.
Maintenance:
- The module is maintenance-free under normal operation.
- Periodic verification of calibration is recommended for critical measurement applications.
- Keep connectors clean and free from corrosion.
Firmware/Updates:
The 5B47-T06 is an analog hardware module with no firmware; updates are not required. Calibration data is factory-set and stable over time.
Serviceability:
Modules are not user-serviceable; defective units should be replaced or returned for factory service.
Storage and Handling:
- Store in a dry, temperature-controlled environment (-55°C to +100°C).
- Protect from electrostatic discharge (ESD) during handling.
- Avoid mechanical shock or impact.
Ordering Information:
- Part Number: 5B47-T06
- Description: 5B module, Thermocouple Type T, -100°C to +400°C input, 0–5 V output, linearized
- Series: 5B Series Signal Conditioning Modules
- Packaging: Individually boxed, with calibration certificate and installation guide
Summary
The 5B47-T06 is a high-performance, isolated thermocouple input module engineered for precise temperature measurement and signal conditioning in industrial and laboratory environments. It converts a Type T thermocouple input (-100°C to +400°C) into a clean, linearized 0–5 V output signal, ready for direct interface with analog input systems. With built-in cold-junction compensation, galvanic isolation, and robust filtering, the module ensures accurate, stable, and noise-resistant operation. Its compact 5B form factor, plug-in installation, and compatibility with standard backplanes make it ideal for scalable, multi-channel temperature monitoring systems.
Designed to meet stringent industrial standards for accuracy, isolation, and reliability, the 5B47-T06 represents a dependable solution for temperature measurement applications requiring precision, safety, and long-term stability.
Name: 5B47-T06
Model: 5B47-T06
Series: 5B Series Signal Conditioning Modules
Article Number: 5B47-T06
Manufacturer: (Typically produced by Analog Devices / Measurement Computing or compatible 5B module manufacturers)
The 5B47-T06 is a precision signal conditioning module designed for thermocouple type T (copper-constantan) temperature measurement applications. It belongs to the 5B Series of modular, isolated analog signal conditioners widely used in industrial, laboratory, and process control environments. The module provides a linearized, isolated, and amplified analog output proportional to the thermocouple input signal. Specifically, it converts a Type T thermocouple input range of -100°C to +400°C into a standardized 0–5 V analog output, suitable for direct interface with data acquisition systems, PLCs, and analog input cards.
2. Key Features
- Thermocouple Type T Input: Designed for copper-constantan thermocouples, offering high accuracy and stability over the specified temperature range.
- Input Range: -100°C to +400°C, covering a broad span suitable for low- to medium-temperature industrial and laboratory processes.
- Output Signal: 0–5 V DC linearized output, compatible with most analog input systems.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion across the entire range.
- Galvanic Isolation: Provides 1500 V RMS isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- High Accuracy and Stability: Typical accuracy better than ±0.1% of full scale, with low drift over time and temperature.
- Compact Modular Design: Standard 5B form factor for use in backplanes or DIN-rail carriers, enabling flexible system configuration.
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes and data acquisition systems.
- Low Power Consumption: Designed for efficient operation in multi-channel systems.
- Rugged Industrial Construction: Encapsulated module for protection against vibration, humidity, and electrical interference.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | 5B47-T06 |
| Input Type | Thermocouple Type T (Copper-Constantan) |
| Input Range | -100°C to +400°C |
| Output Range | 0 to +5 V DC |
| Output Impedance | < 1 Ω |
| Input Impedance | > 10 MΩ |
| Accuracy | ±0.1% of full scale typical |
| Linearity Error | ±0.05% of full scale |
| Isolation Voltage | 1500 V RMS (input-to-output and power-to-output) |
| Common Mode Rejection (CMR) | > 100 dB at 50/60 Hz |
| Bandwidth | Typically 3 Hz (low-pass filtered for noise reduction) |
| Response Time | 100 ms typical to 90% of final value |
| Temperature Coefficient | ±0.01%/°C of full scale |
| Power Supply Voltage | +5 V DC nominal (from backplane) |
| Power Consumption | Approximately 25 mW typical |
| Operating Temperature Range | -40°C to +85°C |
| Storage Temperature Range | -55°C to +100°C |
| Relative Humidity | 0–95% non-condensing |
| Dimensions | Approx. 60 mm (L) × 52 mm (W) × 12.5 mm (H) |
| Weight | Approx. 45 g |
| Mounting | Plug-in module for 5B backplane or DIN-rail carrier |
| Material | Molded thermoplastic housing, epoxy encapsulated electronics |
4. Functionality
The 5B47-T06 operates as a precision thermocouple signal conditioner. It accepts a low-level millivolt signal from a Type T thermocouple and performs several key functions internally:
1. Cold-Junction Compensation (CJC): The module measures the ambient temperature at the input terminals and compensates for the thermocouple’s cold junction, ensuring accurate absolute temperature readings.
2. Amplification: The small thermocouple voltage (typically in the microvolt range) is amplified to a standard 0–5 V output signal.
3. Linearization: The nonlinear thermocouple response is corrected using internal circuitry, providing a linear voltage output proportional to temperature.
4. Isolation: Input, output, and power circuits are galvanically isolated, preventing ground loops and protecting connected equipment.
5. Filtering: Internal low-pass filtering minimizes noise and interference from industrial environments.
Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement systems
- Environmental test chambers
- Data acquisition systems (DAQ)
- PLC analog input expansion
- HVAC and refrigeration monitoring
- Energy management and thermal profiling
Compatibility:
The module is compatible with all standard 5B backplanes, carriers, and data acquisition systems supporting 0–5 V analog inputs. It can interface directly with A/D converters, controllers, and monitoring software.
5. Components & Accessories
Included Items:
- 5B47-T06 signal conditioning module
- Integrated cold-junction compensation sensor
- Factory calibration and test documentation
Optional Accessories:
- 5B01, 5B02, 5B03, or 5B08 backplanes (for multi-channel installations)
- 5B Series DIN-rail mounting kits
- Shielded thermocouple input cables
- Terminal blocks and screw connectors for thermocouple wiring
- Protective covers and labeling kits
Connectors:
- Input: Screw terminal or plug-in connector for thermocouple leads (copper-constantan)
- Output: 0–5 V analog output via backplane connector
- Power: Supplied through backplane bus (+5 V DC)
6. Installation & Setup
Requirements:
- Compatible 5B backplane or carrier with +5 V DC supply
- Proper thermocouple wiring (Type T, copper-constantan)
- Stable ambient conditions for accurate cold-junction compensation
Mounting Options:
- Plug directly into a 5B backplane slot
- Mount on DIN rail using a 5B Series carrier
- Ensure adequate spacing for ventilation and access
Configuration Steps:
1. Insert the 5B47-T06 module into the designated backplane slot.
2. Connect the Type T thermocouple leads to the input terminals, observing correct polarity.
3. Connect the backplane output to the data acquisition or control system analog input.
4. Power the backplane with +5 V DC.
5. Verify output scaling: 0 V corresponds to -100°C, 5 V corresponds to +400°C.
6. Perform system calibration if required by the application.
Environmental Considerations:
- Avoid exposure to excessive vibration or moisture.
- Maintain ambient temperature within the specified operating range.
- Ensure thermocouple junctions are properly shielded from electrical noise sources.
7. Performance & Capabilities
The 5B47-T06 delivers high-precision, stable, and noise-immune temperature measurement performance.
Speed:
- Response time of approximately 100 ms ensures near real-time temperature tracking for most process control applications.
Capacity:
- Each module handles one thermocouple input channel; multiple modules can be combined in a backplane for multi-channel systems.
Efficiency:
- Low power consumption (<25 mW) allows dense channel configurations without excessive heat buildup.
Accuracy and Stability:
- Factory-calibrated for ±0.1% full-scale accuracy.
- Excellent long-term stability with minimal drift.
- High common-mode rejection (>100 dB) ensures reliable operation in electrically noisy environments.
Limitations:
- Designed specifically for Type T thermocouples; not suitable for other thermocouple types without corresponding module variants (e.g., 5B47-K for Type K).
- Output limited to 0–5 V range; systems requiring 0–10 V or 4–20 mA outputs require additional signal conditioning.
- Bandwidth limited to a few hertz, optimized for temperature signals rather than fast-changing inputs.
8. Standards & Compliance
The 5B47-T06 complies with relevant industrial and safety standards for signal conditioning modules:
- Electrical Isolation: 1500 V RMS per ANSI/ISA and IEC standards for reinforced isolation.
- EMC Compliance: Designed to meet EN 61326-1 (Industrial Environment) for electromagnetic compatibility.
- Safety Standards: Conforms to UL, CE, and CSA requirements for low-voltage and industrial control equipment.
- RoHS Compliance: Fully compliant with the Restriction of Hazardous Substances Directive (RoHS 2011/65/EU).
- Temperature Measurement Standards: Calibrated according to ITS-90 thermocouple reference tables for Type T.
- Quality Assurance: Manufactured under ISO 9001-certified quality management systems.
9. Additional Information
Warranty:
Typically supplied with a 1-year limited warranty covering defects in materials and workmanship under normal operating conditions. Extended warranty options may be available depending on the distributor or manufacturer.
Support:
Technical support includes application notes, wiring diagrams, and calibration procedures. Manufacturer and authorized distributors provide assistance for integration with data acquisition systems and troubleshooting.
Maintenance:
- The module is maintenance-free under normal operation.
- Periodic verification of calibration is recommended for critical measurement applications.
- Keep connectors clean and free from corrosion.
Firmware/Updates:
The 5B47-T06 is an analog hardware module with no firmware; updates are not required. Calibration data is factory-set and stable over time.
Serviceability:
Modules are not user-serviceable; defective units should be replaced or returned for factory service.
Storage and Handling:
- Store in a dry, temperature-controlled environment (-55°C to +100°C).
- Protect from electrostatic discharge (ESD) during handling.
- Avoid mechanical shock or impact.
Ordering Information:
- Part Number: 5B47-T06
- Description: 5B module, Thermocouple Type T, -100°C to +400°C input, 0–5 V output, linearized
- Series: 5B Series Signal Conditioning Modules
- Packaging: Individually boxed, with calibration certificate and installation guide
Summary
The 5B47-T06 is a high-performance, isolated thermocouple input module engineered for precise temperature measurement and signal conditioning in industrial and laboratory environments. It converts a Type T thermocouple input (-100°C to +400°C) into a clean, linearized 0–5 V output signal, ready for direct interface with analog input systems. With built-in cold-junction compensation, galvanic isolation, and robust filtering, the module ensures accurate, stable, and noise-resistant operation. Its compact 5B form factor, plug-in installation, and compatibility with standard backplanes make it ideal for scalable, multi-channel temperature monitoring systems.
Designed to meet stringent industrial standards for accuracy, isolation, and reliability, the 5B47-T06 represents a dependable solution for temperature measurement applications requiring precision, safety, and long-term stability.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.