- Dual Isolated Serial Ports: Two independent RS422/RS485 ports with galvanic ground isolation for enhanced signal integrity and protection against ground loops and electrical noise.
- Selectable Interface per Port: Each port can be configured individually as RS422 or RS485 via onboard DIP switches, allowing flexible deployment across different communication standards.
- High Compatibility: Fully compatible with PCI Express bus architecture; plug-and-play installation with automatic I/O, memory, and IRQ mapping assigned by the PCI BIOS.
- Advanced Controller: Utilizes the Moschip MCS9922 serial communication controller, providing high-speed data transfer and efficient interrupt handling.
- Wide Baud Rate Range: Supports baud rates from 50 bps up to 115,200 bps, suitable for a wide range of industrial serial communication applications.
- ADDC (Auto Data Direction Control): Built-in ADDC feature for RS485 mode enables automatic control of data direction, eliminating the need for manual RTS signal handling.
- Industrial-Grade Design: Designed for industrial control systems with robust isolation, wide environmental tolerance, and reliable long-term operation.
- Operating System Support: Compatible with Windows 2000, XP, Vista, Windows 7, and Linux distributions.
- Compact Form Factor: Standard PCIe card dimensions (100 mm × 97 mm) with optional low-profile bracket for compact system integration.
- DB9 Male Connectors: Each port is terminated with a standard DB9 male connector for easy connection to industrial serial devices.
- Plug & Play Configuration: Fully automatic resource allocation (I/O, memory, IRQ) by PCI BIOS, simplifying installation and avoiding conflicts.
- Ground Isolation: Each port is electrically isolated to prevent damage from voltage differences and to ensure stable communication in noisy environments.
- Selectable Interface per Port: Each port can be configured individually as RS422 or RS485 via onboard DIP switches, allowing flexible deployment across different communication standards.
- High Compatibility: Fully compatible with PCI Express bus architecture; plug-and-play installation with automatic I/O, memory, and IRQ mapping assigned by the PCI BIOS.
- Advanced Controller: Utilizes the Moschip MCS9922 serial communication controller, providing high-speed data transfer and efficient interrupt handling.
- Wide Baud Rate Range: Supports baud rates from 50 bps up to 115,200 bps, suitable for a wide range of industrial serial communication applications.
- ADDC (Auto Data Direction Control): Built-in ADDC feature for RS485 mode enables automatic control of data direction, eliminating the need for manual RTS signal handling.
- Industrial-Grade Design: Designed for industrial control systems with robust isolation, wide environmental tolerance, and reliable long-term operation.
- Operating System Support: Compatible with Windows 2000, XP, Vista, Windows 7, and Linux distributions.
- Compact Form Factor: Standard PCIe card dimensions (100 mm × 97 mm) with optional low-profile bracket for compact system integration.
- DB9 Male Connectors: Each port is terminated with a standard DB9 male connector for easy connection to industrial serial devices.
- Plug & Play Configuration: Fully automatic resource allocation (I/O, memory, IRQ) by PCI BIOS, simplifying installation and avoiding conflicts.
- Ground Isolation: Each port is electrically isolated to prevent damage from voltage differences and to ensure stable communication in noisy environments.
1. Product Overview
Product Name: PCIe Isolated 2-Port RS422/485 Card
Model: A132-I
Series: APCIe Advanced PCIe Serial Communication Card Series
Article Number: A132-I
Manufacturer: Rayon Technology Co., Ltd.
Manufacturer Address: 2F, No. 177, Chung Shan 2 Rd., Lu Chou City, Taipei Hsien, Taiwan
Contact: Tel: +886-2-82858362 | Fax: +886-2-82857065
Email: rayon@ms1.hinet.net
Websites: [www.rayontech.com](http://www.rayontech.com), [www.computex.com.tw/rayon](http://www.computex.com.tw/rayon)
The Rayon A132-I is a high-performance, industrial-grade PCI Express (PCIe) serial communication card designed to provide two ground-isolated RS422/RS485 ports. It belongs to Rayon’s APCIe series of advanced serial interface cards, which are engineered for robust, noise-immune, and flexible serial communication in industrial control, automation, and embedded computing environments. The A132-I integrates Moschip’s MCS9922 controller and supports full plug-and-play configuration through the PCI BIOS, ensuring seamless installation and reliable operation across multiple operating systems including Windows and Linux.
2. Key Features
- Dual Isolated Serial Ports: Two independent RS422/RS485 ports with galvanic ground isolation for enhanced signal integrity and protection against ground loops and electrical noise.
- Selectable Interface per Port: Each port can be configured individually as RS422 or RS485 via onboard DIP switches, allowing flexible deployment across different communication standards.
- High Compatibility: Fully compatible with PCI Express bus architecture; plug-and-play installation with automatic I/O, memory, and IRQ mapping assigned by the PCI BIOS.
- Advanced Controller: Utilizes the Moschip MCS9922 serial communication controller, providing high-speed data transfer and efficient interrupt handling.
- Wide Baud Rate Range: Supports baud rates from 50 bps up to 115,200 bps, suitable for a wide range of industrial serial communication applications.
- ADDC (Auto Data Direction Control): Built-in ADDC feature for RS485 mode enables automatic control of data direction, eliminating the need for manual RTS signal handling.
- Industrial-Grade Design: Designed for industrial control systems with robust isolation, wide environmental tolerance, and reliable long-term operation.
- Operating System Support: Compatible with Windows 2000, XP, Vista, Windows 7, and Linux distributions.
- Compact Form Factor: Standard PCIe card dimensions (100 mm × 97 mm) with optional low-profile bracket for compact system integration.
- DB9 Male Connectors: Each port is terminated with a standard DB9 male connector for easy connection to industrial serial devices.
- Plug & Play Configuration: Fully automatic resource allocation (I/O, memory, IRQ) by PCI BIOS, simplifying installation and avoiding conflicts.
- Ground Isolation: Each port is electrically isolated to prevent damage from voltage differences and to ensure stable communication in noisy environments.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | A132-I |
| Bus Interface | PCI Express (PCIe) |
| Controller Chip | Moschip MCS9922 |
| Number of Ports | 2 |
| Interface Type | RS422 / RS485 (selectable per port) |
| Isolation | Ground isolated per port |
| Baud Rate | 50 bps to 115,200 bps |
| Connector Type | 2 × DB9 male connectors |
| Configuration Method | DIP switch selectable per port |
| I/O Mapping | Assigned by PCI BIOS |
| Memory Mapping | Assigned by PCI BIOS |
| IRQ Mapping | Assigned by PCI BIOS |
| Dimensions | 100 mm (L) × 97 mm (W) |
| Bracket Type | Standard PCIe bracket (low-profile optional) |
| Operating Temperature | 0°C to 55°C |
| Storage Temperature | 0°C to 65°C |
| Operating Humidity | 10% to 95% RH (non-condensing) |
| Storage Humidity | 5% to 95% RH (non-condensing) |
| Material | Industrial-grade PCB with EMI shielding |
| Power Source | Supplied via PCIe bus |
| Isolation Voltage | Ground isolation per port (typical 1 kV or higher) |
| Compliance | PCI Express Base Specification compatible |
4. Functionality
The A132-I provides two independent, isolated serial communication channels that can be configured as RS422 or RS485 interfaces. Each port’s mode is selected using onboard DIP switches:
- RS422 Mode: Supports full-duplex differential signaling for point-to-point or multi-drop communication. Ideal for long-distance, high-speed data transmission with minimal noise interference.
- RS485 Mode: Supports half-duplex differential signaling for multi-drop networks. The built-in Auto Data Direction Control (ADDC) automatically manages transmit and receive switching, simplifying software control and preventing data collisions.
Use Cases and Applications:
- Industrial automation and process control systems
- SCADA and PLC communication
- Data acquisition and monitoring systems
- Embedded control and instrumentation
- Serial device networking and integration
- Communication with sensors, controllers, and industrial equipment
Compatibility:
- Fully compatible with PCIe slots on standard PC/AT systems.
- Supported operating systems include Windows 2000, XP, Vista, Windows 7, and Linux (kernel 2.6.x and later).
- Compatible with Moschip MCS9922 drivers for both Windows and Linux environments.
5. Components & Accessories
Included Items:
- A132-I PCIe card (2-port RS422/RS485 isolated)
- Standard PCIe bracket (low-profile bracket available upon request)
- User manual and driver CD (Windows and Linux drivers)
- Quick installation guide
Optional Accessories:
- Low-profile bracket: For installation in compact or embedded systems.
- TB485 converter: DB9-to-terminal block adapter for RS485 wiring (DATA+, DATA-, GND).
- RS4232-8 or RS4232-4 Isolated Box: External isolation and signal conversion boxes for extended port configurations.
- Expansion cables: DB9 or DB25 extension cables for custom wiring.
Connectors:
- Two DB9 male connectors, each supporting RS422/RS485 signals.
- Pin assignments follow standard RS422/RS485 definitions:
- Pin 2: RXD+ (Input)
- Pin 3: TXD+ (Output)
- Pin 4: TXD− (Output)
- Pin 5: Isolated GND
- Pin 6: RXD− (Input)
6. Installation & Setup
System Requirements:
- Available PCI Express slot (x1 or higher)
- Supported operating system (Windows 2000/XP/Vista/7 or Linux)
- Administrative privileges for driver installation
Installation Procedure:
1. Power off the host system.
2. Insert the A132-I card into an available PCIe slot.
3. Secure the card with the bracket screw.
4. Connect serial devices to the DB9 connectors.
5. Power on the system.
6. The PCI BIOS automatically assigns I/O, memory, and IRQ resources.
7. Install the appropriate driver:
- Windows: Use the Moschip MCS9922 driver (available on CD or manufacturer’s website).
- Linux: Install via provided installation script (`Install.redhat`) located in `/etc/rayone`.
8. Configure port settings and verify operation via Device Manager (Windows) or `/dev/tty2[1-4][a-b]` devices (Linux).
DIP Switch Configuration:
- Bit 3 controls Port A mode; Bit 4 controls Port B mode.
- OFF (default): RS485 mode
- ON: RS422 mode
RS485 Wiring:
- Short DB9 pins 2 & 3 for DATA+.
- Short DB9 pins 4 & 6 for DATA−.
- Connect GND to pin 5 (isolated ground).
Caution: Do not insert or remove the card while the system is powered on.
7. Performance & Capabilities
- Data Rate: 50 bps to 115,200 bps (software programmable)
- Buffering: 128-byte transmit and receive FIFO per port (MCS9922 controller)
- Interrupt Handling: Reduced CPU load through efficient interrupt management
- Communication Modes: Full-duplex (RS422) and half-duplex (RS485)
- Isolation: Electrical isolation between ports and system ground to prevent interference
- Signal Integrity: Differential signaling minimizes noise and supports long cable runs (up to 1200 meters typical for RS422)
- Auto Data Direction Control: Ensures seamless half-duplex communication in RS485 mode
- Reliability: Designed for continuous industrial operation with stable performance under varying environmental conditions
- Limitations: Maximum baud rate limited to 115.2 kbps; higher rates may require specialized drivers or hardware.
8. Standards & Compliance
- Bus Interface: PCI Express Base Specification compliant
- Controller Compliance: Moschip MCS9922 compatible
- Electrical Standards: EIA/TIA RS422 and RS485 compliant
- Operating System Drivers: Certified for Windows 2000/XP/Vista/7 and Linux kernel 2.6.x+
- Environmental Standards: Designed for industrial temperature and humidity ranges
- Safety and EMC: Ground isolation reduces susceptibility to EMI/RFI interference
- RoHS Compliance: Manufactured with lead-free components and environmentally safe materials
- Plug & Play: Fully compliant with PCI BIOS resource allocation standards
9. Additional Information
Warranty:
- One-year limited warranty covering defects in materials and workmanship.
- Warranty excludes damage caused by misuse, unauthorized servicing, or electrical surges.
- Out-of-warranty repairs available at a flat-rate service charge.
Support & Maintenance:
- Technical support available via email (rayon@ms1.hinet.net).
- Driver updates and documentation downloadable from [www.rayontech.com](http://www.rayontech.com).
- RMA (Return Material Authorization) required for product returns or repairs.
- Users are advised to contact Rayon support before returning products to verify if issues are software-related.
Maintenance Recommendations:
- Ensure proper grounding and isolation when connecting to external devices.
- Avoid hot-swapping the card.
- Periodically check DIP switch settings and cable connections.
- Keep the card free from dust and moisture.
Related Models in the APCIe Series:
- A102: 2-port RS232 PCIe card
- A112: 2-port RS232/RS422/RS485 PCIe card
- A104: 4-port RS232 PCIe card
- A134: 4-port RS422/RS485 PCIe card
- A114: 4-port RS232/RS422/RS485 PCIe card
- A168: 8-port RS232 PCIe card
- A138: 8-port RS422/RS485 PCIe card
- A118: 8-port RS232/RS422/RS485 PCIe card
Driver and Software Notes:
- Windows driver installation uses Moschip’s MCS9922 INF files (e.g., `StnMf.inf`).
- Linux driver installation supports Red Hat, SUSE, and Slackware distributions.
- Device naming convention under Linux: `/dev/tty21a` (Port A), `/dev/tty21b` (Port B).
- Supports up to four cards installed simultaneously in one system.
Troubleshooting Highlights:
- Verify PCI BIOS detects the card (Vendor ID: 9710, Device ID: 9922).
- Confirm correct driver installation if COM ports are not visible.
- Use Rayon’s “RAYMON.EXE” utility for port testing and loopback verification.
- Check IRQ conflicts if communication fails or system hangs.
Summary
The Rayon A132-I PCIe Isolated 2-Port RS422/RS485 Card is a robust, industrial-grade communication interface designed for reliable serial data exchange in demanding environments. With dual isolated ports, flexible RS422/RS485 configuration, and full PCIe plug-and-play support, it provides a versatile solution for system integrators and engineers requiring stable, noise-immune serial connectivity. Its compatibility with multiple operating systems, comprehensive driver support, and straightforward DIP switch configuration make it an ideal choice for industrial automation, control systems, and embedded applications where reliability and electrical isolation are critical.
Product Name: PCIe Isolated 2-Port RS422/485 Card
Model: A132-I
Series: APCIe Advanced PCIe Serial Communication Card Series
Article Number: A132-I
Manufacturer: Rayon Technology Co., Ltd.
Manufacturer Address: 2F, No. 177, Chung Shan 2 Rd., Lu Chou City, Taipei Hsien, Taiwan
Contact: Tel: +886-2-82858362 | Fax: +886-2-82857065
Email: rayon@ms1.hinet.net
Websites: [www.rayontech.com](http://www.rayontech.com), [www.computex.com.tw/rayon](http://www.computex.com.tw/rayon)
The Rayon A132-I is a high-performance, industrial-grade PCI Express (PCIe) serial communication card designed to provide two ground-isolated RS422/RS485 ports. It belongs to Rayon’s APCIe series of advanced serial interface cards, which are engineered for robust, noise-immune, and flexible serial communication in industrial control, automation, and embedded computing environments. The A132-I integrates Moschip’s MCS9922 controller and supports full plug-and-play configuration through the PCI BIOS, ensuring seamless installation and reliable operation across multiple operating systems including Windows and Linux.
2. Key Features
- Dual Isolated Serial Ports: Two independent RS422/RS485 ports with galvanic ground isolation for enhanced signal integrity and protection against ground loops and electrical noise.
- Selectable Interface per Port: Each port can be configured individually as RS422 or RS485 via onboard DIP switches, allowing flexible deployment across different communication standards.
- High Compatibility: Fully compatible with PCI Express bus architecture; plug-and-play installation with automatic I/O, memory, and IRQ mapping assigned by the PCI BIOS.
- Advanced Controller: Utilizes the Moschip MCS9922 serial communication controller, providing high-speed data transfer and efficient interrupt handling.
- Wide Baud Rate Range: Supports baud rates from 50 bps up to 115,200 bps, suitable for a wide range of industrial serial communication applications.
- ADDC (Auto Data Direction Control): Built-in ADDC feature for RS485 mode enables automatic control of data direction, eliminating the need for manual RTS signal handling.
- Industrial-Grade Design: Designed for industrial control systems with robust isolation, wide environmental tolerance, and reliable long-term operation.
- Operating System Support: Compatible with Windows 2000, XP, Vista, Windows 7, and Linux distributions.
- Compact Form Factor: Standard PCIe card dimensions (100 mm × 97 mm) with optional low-profile bracket for compact system integration.
- DB9 Male Connectors: Each port is terminated with a standard DB9 male connector for easy connection to industrial serial devices.
- Plug & Play Configuration: Fully automatic resource allocation (I/O, memory, IRQ) by PCI BIOS, simplifying installation and avoiding conflicts.
- Ground Isolation: Each port is electrically isolated to prevent damage from voltage differences and to ensure stable communication in noisy environments.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | A132-I |
| Bus Interface | PCI Express (PCIe) |
| Controller Chip | Moschip MCS9922 |
| Number of Ports | 2 |
| Interface Type | RS422 / RS485 (selectable per port) |
| Isolation | Ground isolated per port |
| Baud Rate | 50 bps to 115,200 bps |
| Connector Type | 2 × DB9 male connectors |
| Configuration Method | DIP switch selectable per port |
| I/O Mapping | Assigned by PCI BIOS |
| Memory Mapping | Assigned by PCI BIOS |
| IRQ Mapping | Assigned by PCI BIOS |
| Dimensions | 100 mm (L) × 97 mm (W) |
| Bracket Type | Standard PCIe bracket (low-profile optional) |
| Operating Temperature | 0°C to 55°C |
| Storage Temperature | 0°C to 65°C |
| Operating Humidity | 10% to 95% RH (non-condensing) |
| Storage Humidity | 5% to 95% RH (non-condensing) |
| Material | Industrial-grade PCB with EMI shielding |
| Power Source | Supplied via PCIe bus |
| Isolation Voltage | Ground isolation per port (typical 1 kV or higher) |
| Compliance | PCI Express Base Specification compatible |
4. Functionality
The A132-I provides two independent, isolated serial communication channels that can be configured as RS422 or RS485 interfaces. Each port’s mode is selected using onboard DIP switches:
- RS422 Mode: Supports full-duplex differential signaling for point-to-point or multi-drop communication. Ideal for long-distance, high-speed data transmission with minimal noise interference.
- RS485 Mode: Supports half-duplex differential signaling for multi-drop networks. The built-in Auto Data Direction Control (ADDC) automatically manages transmit and receive switching, simplifying software control and preventing data collisions.
Use Cases and Applications:
- Industrial automation and process control systems
- SCADA and PLC communication
- Data acquisition and monitoring systems
- Embedded control and instrumentation
- Serial device networking and integration
- Communication with sensors, controllers, and industrial equipment
Compatibility:
- Fully compatible with PCIe slots on standard PC/AT systems.
- Supported operating systems include Windows 2000, XP, Vista, Windows 7, and Linux (kernel 2.6.x and later).
- Compatible with Moschip MCS9922 drivers for both Windows and Linux environments.
5. Components & Accessories
Included Items:
- A132-I PCIe card (2-port RS422/RS485 isolated)
- Standard PCIe bracket (low-profile bracket available upon request)
- User manual and driver CD (Windows and Linux drivers)
- Quick installation guide
Optional Accessories:
- Low-profile bracket: For installation in compact or embedded systems.
- TB485 converter: DB9-to-terminal block adapter for RS485 wiring (DATA+, DATA-, GND).
- RS4232-8 or RS4232-4 Isolated Box: External isolation and signal conversion boxes for extended port configurations.
- Expansion cables: DB9 or DB25 extension cables for custom wiring.
Connectors:
- Two DB9 male connectors, each supporting RS422/RS485 signals.
- Pin assignments follow standard RS422/RS485 definitions:
- Pin 2: RXD+ (Input)
- Pin 3: TXD+ (Output)
- Pin 4: TXD− (Output)
- Pin 5: Isolated GND
- Pin 6: RXD− (Input)
6. Installation & Setup
System Requirements:
- Available PCI Express slot (x1 or higher)
- Supported operating system (Windows 2000/XP/Vista/7 or Linux)
- Administrative privileges for driver installation
Installation Procedure:
1. Power off the host system.
2. Insert the A132-I card into an available PCIe slot.
3. Secure the card with the bracket screw.
4. Connect serial devices to the DB9 connectors.
5. Power on the system.
6. The PCI BIOS automatically assigns I/O, memory, and IRQ resources.
7. Install the appropriate driver:
- Windows: Use the Moschip MCS9922 driver (available on CD or manufacturer’s website).
- Linux: Install via provided installation script (`Install.redhat`) located in `/etc/rayone`.
8. Configure port settings and verify operation via Device Manager (Windows) or `/dev/tty2[1-4][a-b]` devices (Linux).
DIP Switch Configuration:
- Bit 3 controls Port A mode; Bit 4 controls Port B mode.
- OFF (default): RS485 mode
- ON: RS422 mode
RS485 Wiring:
- Short DB9 pins 2 & 3 for DATA+.
- Short DB9 pins 4 & 6 for DATA−.
- Connect GND to pin 5 (isolated ground).
Caution: Do not insert or remove the card while the system is powered on.
7. Performance & Capabilities
- Data Rate: 50 bps to 115,200 bps (software programmable)
- Buffering: 128-byte transmit and receive FIFO per port (MCS9922 controller)
- Interrupt Handling: Reduced CPU load through efficient interrupt management
- Communication Modes: Full-duplex (RS422) and half-duplex (RS485)
- Isolation: Electrical isolation between ports and system ground to prevent interference
- Signal Integrity: Differential signaling minimizes noise and supports long cable runs (up to 1200 meters typical for RS422)
- Auto Data Direction Control: Ensures seamless half-duplex communication in RS485 mode
- Reliability: Designed for continuous industrial operation with stable performance under varying environmental conditions
- Limitations: Maximum baud rate limited to 115.2 kbps; higher rates may require specialized drivers or hardware.
8. Standards & Compliance
- Bus Interface: PCI Express Base Specification compliant
- Controller Compliance: Moschip MCS9922 compatible
- Electrical Standards: EIA/TIA RS422 and RS485 compliant
- Operating System Drivers: Certified for Windows 2000/XP/Vista/7 and Linux kernel 2.6.x+
- Environmental Standards: Designed for industrial temperature and humidity ranges
- Safety and EMC: Ground isolation reduces susceptibility to EMI/RFI interference
- RoHS Compliance: Manufactured with lead-free components and environmentally safe materials
- Plug & Play: Fully compliant with PCI BIOS resource allocation standards
9. Additional Information
Warranty:
- One-year limited warranty covering defects in materials and workmanship.
- Warranty excludes damage caused by misuse, unauthorized servicing, or electrical surges.
- Out-of-warranty repairs available at a flat-rate service charge.
Support & Maintenance:
- Technical support available via email (rayon@ms1.hinet.net).
- Driver updates and documentation downloadable from [www.rayontech.com](http://www.rayontech.com).
- RMA (Return Material Authorization) required for product returns or repairs.
- Users are advised to contact Rayon support before returning products to verify if issues are software-related.
Maintenance Recommendations:
- Ensure proper grounding and isolation when connecting to external devices.
- Avoid hot-swapping the card.
- Periodically check DIP switch settings and cable connections.
- Keep the card free from dust and moisture.
Related Models in the APCIe Series:
- A102: 2-port RS232 PCIe card
- A112: 2-port RS232/RS422/RS485 PCIe card
- A104: 4-port RS232 PCIe card
- A134: 4-port RS422/RS485 PCIe card
- A114: 4-port RS232/RS422/RS485 PCIe card
- A168: 8-port RS232 PCIe card
- A138: 8-port RS422/RS485 PCIe card
- A118: 8-port RS232/RS422/RS485 PCIe card
Driver and Software Notes:
- Windows driver installation uses Moschip’s MCS9922 INF files (e.g., `StnMf.inf`).
- Linux driver installation supports Red Hat, SUSE, and Slackware distributions.
- Device naming convention under Linux: `/dev/tty21a` (Port A), `/dev/tty21b` (Port B).
- Supports up to four cards installed simultaneously in one system.
Troubleshooting Highlights:
- Verify PCI BIOS detects the card (Vendor ID: 9710, Device ID: 9922).
- Confirm correct driver installation if COM ports are not visible.
- Use Rayon’s “RAYMON.EXE” utility for port testing and loopback verification.
- Check IRQ conflicts if communication fails or system hangs.
Summary
The Rayon A132-I PCIe Isolated 2-Port RS422/RS485 Card is a robust, industrial-grade communication interface designed for reliable serial data exchange in demanding environments. With dual isolated ports, flexible RS422/RS485 configuration, and full PCIe plug-and-play support, it provides a versatile solution for system integrators and engineers requiring stable, noise-immune serial connectivity. Its compatibility with multiple operating systems, comprehensive driver support, and straightforward DIP switch configuration make it an ideal choice for industrial automation, control systems, and embedded applications where reliability and electrical isolation are critical.
-
A132I_Catalog_en.pdf
PDF Catalog
-
APCIE_036E.pdf
Manual
- Rayon-Terminal - Rayon serial port data log debug tool with source
- Rayon-Monitor - Rayon monitor terminal emulation program with source