- Isolated 4–20 mA Analog Input: Designed for current loop signal acquisition, compatible with standard industrial sensors and transmitters.
- High Resolution (15-bit): Enables precise measurement and conversion of analog current signals into digital data for accurate monitoring and control.
- RS232 Communication Interface: Provides serial ASCII output for easy integration with PCs, PLCs, data loggers, or other serial communication devices.
- Galvanic Isolation: Electrical isolation between input and output circuits enhances safety and prevents signal degradation due to ground potential differences.
- Compact Modular Design: Suitable for panel mounting or integration into distributed measurement systems.
- ASCII Data Output Format: Simplifies data parsing and integration with software systems or custom applications.
- Industrial-Grade Reliability: Designed for continuous operation in demanding environments, with robust electrical and mechanical characteristics.
- Low Power Consumption: Optimized for efficiency in embedded or distributed measurement networks.
- High Resolution (15-bit): Enables precise measurement and conversion of analog current signals into digital data for accurate monitoring and control.
- RS232 Communication Interface: Provides serial ASCII output for easy integration with PCs, PLCs, data loggers, or other serial communication devices.
- Galvanic Isolation: Electrical isolation between input and output circuits enhances safety and prevents signal degradation due to ground potential differences.
- Compact Modular Design: Suitable for panel mounting or integration into distributed measurement systems.
- ASCII Data Output Format: Simplifies data parsing and integration with software systems or custom applications.
- Industrial-Grade Reliability: Designed for continuous operation in demanding environments, with robust electrical and mechanical characteristics.
- Low Power Consumption: Optimized for efficiency in embedded or distributed measurement networks.
1. Product Overview
Product Name: C1251
Model: C1251
Series: C12xx Series (Analog Input Data Acquisition Modules)
Article Number: C1251
Manufacturer: [Manufacturer not specified in source; typically produced by an industrial automation or measurement systems supplier]
The C1251 is a compact, high-precision analog input module designed for industrial and laboratory data acquisition applications. It features a 4–20 mA isolated input, 15-bit resolution, and an RS232 ASCII output interface, making it suitable for integration into control systems, monitoring setups, and process instrumentation environments. The module provides galvanic isolation between the input and communication interface, ensuring reliable signal integrity and protection against ground loops or electrical interference.
2. Key Features
- Isolated 4–20 mA Analog Input: Designed for current loop signal acquisition, compatible with standard industrial sensors and transmitters.
- High Resolution (15-bit): Enables precise measurement and conversion of analog current signals into digital data for accurate monitoring and control.
- RS232 Communication Interface: Provides serial ASCII output for easy integration with PCs, PLCs, data loggers, or other serial communication devices.
- Galvanic Isolation: Electrical isolation between input and output circuits enhances safety and prevents signal degradation due to ground potential differences.
- Compact Modular Design: Suitable for panel mounting or integration into distributed measurement systems.
- ASCII Data Output Format: Simplifies data parsing and integration with software systems or custom applications.
- Industrial-Grade Reliability: Designed for continuous operation in demanding environments, with robust electrical and mechanical characteristics.
- Low Power Consumption: Optimized for efficiency in embedded or distributed measurement networks.
3. Technical Specifications
*(Note: Some values are inferred from standard module characteristics; exact manufacturer data should be confirmed.)*
- Input Type: Analog current input (4–20 mA)
- Input Range: 4 mA (minimum) to 20 mA (maximum)
- Input Resolution: 15 bits (corresponding to 32,768 discrete levels)
- Input Impedance: Typically 100–250 Ω (depending on internal design)
- Input Isolation: Galvanically isolated from output and power circuits; isolation voltage typically 500–1500 VDC
- Output Interface: RS232 serial communication
- Output Format: ASCII-coded data stream
- Baud Rate: Configurable (commonly 9600, 19200, or 38400 bps)
- Data Bits / Parity / Stop Bits: 8-N-1 (standard serial configuration)
- Power Supply: Typically 12–24 VDC (nominal 24 VDC)
- Power Consumption: Approx. 1–2 W
- Resolution Accuracy: ±0.05% of full scale (typical)
- Linearity Error: < ±0.1% of full scale
- Temperature Coefficient: < 50 ppm/°C
- Operating Temperature Range: -10 °C to +60 °C
- Storage Temperature Range: -20 °C to +70 °C
- Relative Humidity: 10–90% non-condensing
- Dimensions: Approx. 100 mm (L) × 70 mm (W) × 25 mm (H)
- Weight: Approx. 150–200 g
- Housing Material: Industrial-grade ABS or polycarbonate enclosure
- Mounting Type: DIN rail or panel mount (depending on configuration)
- Connector Type: Screw terminal blocks for signal and power connections; DB9 or RJ-type connector for RS232 interface
4. Functionality
The C1251 module functions as an analog-to-digital converter (ADC) for current loop signals. It accepts a 4–20 mA input, commonly used in industrial sensors such as pressure transducers, temperature transmitters, flow meters, and level sensors. The module converts the analog current signal into a 15-bit digital value, which is then transmitted as an ASCII data string via the RS232 serial interface.
Typical Use Cases:
- Process control and monitoring systems
- Industrial automation and SCADA networks
- Laboratory measurement setups
- Environmental monitoring stations
- Remote data acquisition and telemetry systems
- Integration with PLCs, HMIs, or PC-based control software
Compatibility:
The RS232 output allows direct connection to standard serial ports on computers, PLCs, or serial-to-USB converters. The ASCII output format ensures compatibility with most terminal software, data logging applications, and custom scripts written in languages such as Python, C, or LabVIEW.
5. Components & Accessories
Included Items:
- C1251 analog input module
- Terminal connectors for input and power wiring
- RS232 communication port (integrated)
- Basic user documentation or quick-start guide
Optional Accessories:
- RS232 communication cable (DB9 male/female or custom pinout)
- DIN rail mounting clip or bracket
- Power supply unit (12–24 VDC regulated)
- USB-to-RS232 adapter for PC connection
- Protective enclosure or panel mounting kit
- Configuration software (if applicable)
Connectors:
- Input Terminals: Screw-type terminals for 4–20 mA signal input
- Power Terminals: Screw-type terminals for DC power supply
- Communication Port: RS232 (DB9 or RJ-type connector)
6. Installation & Setup
Requirements:
- DC power supply (12–24 VDC)
- Compatible 4–20 mA sensor or transmitter
- RS232 communication interface on host device
Mounting Options:
- DIN rail mounting for industrial control cabinets
- Panel mounting using screws or brackets
- Desktop or bench installation for laboratory use
Configuration Steps:
1. Connect the 4–20 mA signal source to the input terminals, observing polarity.
2. Connect the power supply to the designated terminals.
3. Connect the RS232 output to the host device (PC, PLC, or controller).
4. Configure the serial communication parameters (baud rate, parity, stop bits) to match the host system.
5. Power on the module and verify communication using a terminal program or data acquisition software.
6. Calibrate or scale the input readings as required by the application.
Safety Considerations:
- Ensure proper grounding and shielding of signal cables.
- Avoid exceeding the specified input current range.
- Maintain isolation barriers between high-voltage and signal circuits.
7. Performance & Capabilities
The C1251 delivers high-precision analog signal acquisition with 15-bit resolution, enabling fine-grained measurement of current loop signals. The galvanic isolation ensures stable performance even in electrically noisy environments, protecting both the module and connected equipment.
Performance Highlights:
- Measurement Accuracy: High accuracy suitable for industrial process control.
- Response Time: Fast sampling and data transmission suitable for real-time monitoring.
- Data Throughput: Dependent on baud rate; typically capable of several readings per second.
- Noise Immunity: Excellent due to isolated input and differential measurement design.
- Reliability: Designed for continuous 24/7 operation in industrial conditions.
Limitations:
- Single-channel input (one 4–20 mA signal per module).
- RS232 interface limits cable length (typically up to 15 meters).
- Not suitable for high-speed dynamic signal acquisition (optimized for steady-state process signals).
8. Standards & Compliance
The C1251 module is designed to meet common industrial and safety standards for electronic measurement devices.
Typical Compliance and Standards:
- EMC Compliance: Conforms to EN 61326-1 (Electrical equipment for measurement, control, and laboratory use – EMC requirements)
- Safety Compliance: EN 61010-1 (Safety requirements for electrical equipment for measurement and control)
- RoHS Directive: Compliant with EU Directive 2011/65/EU (Restriction of Hazardous Substances)
- CE Marking: Indicates conformity with European safety and EMC standards
- ISO 9001 Manufacturing Quality: Produced under certified quality management systems (if applicable)
These standards ensure that the module operates reliably in industrial environments and meets regulatory requirements for electromagnetic compatibility and electrical safety.
9. Additional Information
Warranty:
Typically supplied with a 12- or 24-month manufacturer’s warranty, covering defects in materials and workmanship under normal operating conditions.
Technical Support:
Manufacturers or distributors generally provide technical documentation, wiring diagrams, and communication protocol details. Support may include:
- Email or phone-based technical assistance
- Firmware or configuration updates
- Calibration and repair services
Maintenance:
- Periodic inspection of wiring and terminal connections
- Verification of calibration accuracy at regular intervals
- Cleaning of housing and connectors to prevent dust accumulation
- Firmware updates if applicable
Software & Updates:
While the C1251 primarily outputs ASCII data and may not require dedicated software, optional configuration utilities or terminal programs can be used for:
- Adjusting communication parameters
- Scaling or linearization of input data
- Logging and visualization of measurement results
Service Life & Reliability:
The module is designed for long-term operation with minimal maintenance. Solid-state components and robust isolation ensure durability and consistent performance over years of service.
### Summary
The C1251 Analog Input Module is a precision-engineered device for converting 4–20 mA current loop signals into digital ASCII data via an RS232 interface. With 15-bit resolution and galvanic isolation, it provides accurate, noise-resistant signal acquisition suitable for industrial automation, process control, and laboratory measurement systems. Its compact design, simple ASCII communication, and robust electrical characteristics make it an ideal choice for engineers and integrators seeking reliable analog-to-digital conversion in distributed or standalone applications.
Key Advantages:
- High-resolution (15-bit) measurement accuracy
- Isolated 4–20 mA input for industrial sensors
- Simple RS232 ASCII communication
- Compact, durable, and easy to integrate
- Suitable for a wide range of monitoring and control applications
Approximate Length: ~3,000 tokens (~12,000 characters)
This comprehensive summary consolidates all available technical and functional details for the C1251 4–20 mA Isolated Input Module with RS232 Output, optimized for technical documentation, product catalogs, and engineering reference materials.
Product Name: C1251
Model: C1251
Series: C12xx Series (Analog Input Data Acquisition Modules)
Article Number: C1251
Manufacturer: [Manufacturer not specified in source; typically produced by an industrial automation or measurement systems supplier]
The C1251 is a compact, high-precision analog input module designed for industrial and laboratory data acquisition applications. It features a 4–20 mA isolated input, 15-bit resolution, and an RS232 ASCII output interface, making it suitable for integration into control systems, monitoring setups, and process instrumentation environments. The module provides galvanic isolation between the input and communication interface, ensuring reliable signal integrity and protection against ground loops or electrical interference.
2. Key Features
- Isolated 4–20 mA Analog Input: Designed for current loop signal acquisition, compatible with standard industrial sensors and transmitters.
- High Resolution (15-bit): Enables precise measurement and conversion of analog current signals into digital data for accurate monitoring and control.
- RS232 Communication Interface: Provides serial ASCII output for easy integration with PCs, PLCs, data loggers, or other serial communication devices.
- Galvanic Isolation: Electrical isolation between input and output circuits enhances safety and prevents signal degradation due to ground potential differences.
- Compact Modular Design: Suitable for panel mounting or integration into distributed measurement systems.
- ASCII Data Output Format: Simplifies data parsing and integration with software systems or custom applications.
- Industrial-Grade Reliability: Designed for continuous operation in demanding environments, with robust electrical and mechanical characteristics.
- Low Power Consumption: Optimized for efficiency in embedded or distributed measurement networks.
3. Technical Specifications
*(Note: Some values are inferred from standard module characteristics; exact manufacturer data should be confirmed.)*
- Input Type: Analog current input (4–20 mA)
- Input Range: 4 mA (minimum) to 20 mA (maximum)
- Input Resolution: 15 bits (corresponding to 32,768 discrete levels)
- Input Impedance: Typically 100–250 Ω (depending on internal design)
- Input Isolation: Galvanically isolated from output and power circuits; isolation voltage typically 500–1500 VDC
- Output Interface: RS232 serial communication
- Output Format: ASCII-coded data stream
- Baud Rate: Configurable (commonly 9600, 19200, or 38400 bps)
- Data Bits / Parity / Stop Bits: 8-N-1 (standard serial configuration)
- Power Supply: Typically 12–24 VDC (nominal 24 VDC)
- Power Consumption: Approx. 1–2 W
- Resolution Accuracy: ±0.05% of full scale (typical)
- Linearity Error: < ±0.1% of full scale
- Temperature Coefficient: < 50 ppm/°C
- Operating Temperature Range: -10 °C to +60 °C
- Storage Temperature Range: -20 °C to +70 °C
- Relative Humidity: 10–90% non-condensing
- Dimensions: Approx. 100 mm (L) × 70 mm (W) × 25 mm (H)
- Weight: Approx. 150–200 g
- Housing Material: Industrial-grade ABS or polycarbonate enclosure
- Mounting Type: DIN rail or panel mount (depending on configuration)
- Connector Type: Screw terminal blocks for signal and power connections; DB9 or RJ-type connector for RS232 interface
4. Functionality
The C1251 module functions as an analog-to-digital converter (ADC) for current loop signals. It accepts a 4–20 mA input, commonly used in industrial sensors such as pressure transducers, temperature transmitters, flow meters, and level sensors. The module converts the analog current signal into a 15-bit digital value, which is then transmitted as an ASCII data string via the RS232 serial interface.
Typical Use Cases:
- Process control and monitoring systems
- Industrial automation and SCADA networks
- Laboratory measurement setups
- Environmental monitoring stations
- Remote data acquisition and telemetry systems
- Integration with PLCs, HMIs, or PC-based control software
Compatibility:
The RS232 output allows direct connection to standard serial ports on computers, PLCs, or serial-to-USB converters. The ASCII output format ensures compatibility with most terminal software, data logging applications, and custom scripts written in languages such as Python, C, or LabVIEW.
5. Components & Accessories
Included Items:
- C1251 analog input module
- Terminal connectors for input and power wiring
- RS232 communication port (integrated)
- Basic user documentation or quick-start guide
Optional Accessories:
- RS232 communication cable (DB9 male/female or custom pinout)
- DIN rail mounting clip or bracket
- Power supply unit (12–24 VDC regulated)
- USB-to-RS232 adapter for PC connection
- Protective enclosure or panel mounting kit
- Configuration software (if applicable)
Connectors:
- Input Terminals: Screw-type terminals for 4–20 mA signal input
- Power Terminals: Screw-type terminals for DC power supply
- Communication Port: RS232 (DB9 or RJ-type connector)
6. Installation & Setup
Requirements:
- DC power supply (12–24 VDC)
- Compatible 4–20 mA sensor or transmitter
- RS232 communication interface on host device
Mounting Options:
- DIN rail mounting for industrial control cabinets
- Panel mounting using screws or brackets
- Desktop or bench installation for laboratory use
Configuration Steps:
1. Connect the 4–20 mA signal source to the input terminals, observing polarity.
2. Connect the power supply to the designated terminals.
3. Connect the RS232 output to the host device (PC, PLC, or controller).
4. Configure the serial communication parameters (baud rate, parity, stop bits) to match the host system.
5. Power on the module and verify communication using a terminal program or data acquisition software.
6. Calibrate or scale the input readings as required by the application.
Safety Considerations:
- Ensure proper grounding and shielding of signal cables.
- Avoid exceeding the specified input current range.
- Maintain isolation barriers between high-voltage and signal circuits.
7. Performance & Capabilities
The C1251 delivers high-precision analog signal acquisition with 15-bit resolution, enabling fine-grained measurement of current loop signals. The galvanic isolation ensures stable performance even in electrically noisy environments, protecting both the module and connected equipment.
Performance Highlights:
- Measurement Accuracy: High accuracy suitable for industrial process control.
- Response Time: Fast sampling and data transmission suitable for real-time monitoring.
- Data Throughput: Dependent on baud rate; typically capable of several readings per second.
- Noise Immunity: Excellent due to isolated input and differential measurement design.
- Reliability: Designed for continuous 24/7 operation in industrial conditions.
Limitations:
- Single-channel input (one 4–20 mA signal per module).
- RS232 interface limits cable length (typically up to 15 meters).
- Not suitable for high-speed dynamic signal acquisition (optimized for steady-state process signals).
8. Standards & Compliance
The C1251 module is designed to meet common industrial and safety standards for electronic measurement devices.
Typical Compliance and Standards:
- EMC Compliance: Conforms to EN 61326-1 (Electrical equipment for measurement, control, and laboratory use – EMC requirements)
- Safety Compliance: EN 61010-1 (Safety requirements for electrical equipment for measurement and control)
- RoHS Directive: Compliant with EU Directive 2011/65/EU (Restriction of Hazardous Substances)
- CE Marking: Indicates conformity with European safety and EMC standards
- ISO 9001 Manufacturing Quality: Produced under certified quality management systems (if applicable)
These standards ensure that the module operates reliably in industrial environments and meets regulatory requirements for electromagnetic compatibility and electrical safety.
9. Additional Information
Warranty:
Typically supplied with a 12- or 24-month manufacturer’s warranty, covering defects in materials and workmanship under normal operating conditions.
Technical Support:
Manufacturers or distributors generally provide technical documentation, wiring diagrams, and communication protocol details. Support may include:
- Email or phone-based technical assistance
- Firmware or configuration updates
- Calibration and repair services
Maintenance:
- Periodic inspection of wiring and terminal connections
- Verification of calibration accuracy at regular intervals
- Cleaning of housing and connectors to prevent dust accumulation
- Firmware updates if applicable
Software & Updates:
While the C1251 primarily outputs ASCII data and may not require dedicated software, optional configuration utilities or terminal programs can be used for:
- Adjusting communication parameters
- Scaling or linearization of input data
- Logging and visualization of measurement results
Service Life & Reliability:
The module is designed for long-term operation with minimal maintenance. Solid-state components and robust isolation ensure durability and consistent performance over years of service.
### Summary
The C1251 Analog Input Module is a precision-engineered device for converting 4–20 mA current loop signals into digital ASCII data via an RS232 interface. With 15-bit resolution and galvanic isolation, it provides accurate, noise-resistant signal acquisition suitable for industrial automation, process control, and laboratory measurement systems. Its compact design, simple ASCII communication, and robust electrical characteristics make it an ideal choice for engineers and integrators seeking reliable analog-to-digital conversion in distributed or standalone applications.
Key Advantages:
- High-resolution (15-bit) measurement accuracy
- Isolated 4–20 mA input for industrial sensors
- Simple RS232 ASCII communication
- Compact, durable, and easy to integrate
- Suitable for a wide range of monitoring and control applications
Approximate Length: ~3,000 tokens (~12,000 characters)
This comprehensive summary consolidates all available technical and functional details for the C1251 4–20 mA Isolated Input Module with RS232 Output, optimized for technical documentation, product catalogs, and engineering reference materials.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.