- Ethernet Connectivity: 10/100 Mbps auto‑negotiating Ethernet interface (IEEE 802.3/802.3u) with RJ‑45 connector.
- Protocol Support: Native Modbus/TCP server; also supports UDP for broadcast data streaming and event reporting to up to eight hosts.
- Digital I/O Configuration:
- 12 × Isolated Digital Inputs (wet contact, single‑ended, common source/ground).
- 6 × Isolated Digital Outputs (open‑collector NPN type).
- Isolation Protection: 3000 V DC optical isolation between I/O and logic circuits.
- Smart Functions:
- DI latch and 32‑bit counter (1 kHz) per input channel.
- DO pulse output and delay output modes.
- Auto‑off timer for digital outputs.
- Local DI‑to‑DO mirroring for hardware signal replication.
- Web Server: Embedded HTTP server for remote monitoring and control via standard browsers.
- Software Integration: Compatible with ExpertDAQ Windows Utility, Modbus/TCP OPC servers, and ActiveX/DLL APIs for custom application development.
- Flexible Mounting: DIN‑rail, wall, or stack mounting options.
- Industrial Reliability: Wide operating temperature range (‑25 °C to +75 °C), surge and reverse‑voltage protection, and robust ABS enclosure.
- Protocol Support: Native Modbus/TCP server; also supports UDP for broadcast data streaming and event reporting to up to eight hosts.
- Digital I/O Configuration:
- 12 × Isolated Digital Inputs (wet contact, single‑ended, common source/ground).
- 6 × Isolated Digital Outputs (open‑collector NPN type).
- Isolation Protection: 3000 V DC optical isolation between I/O and logic circuits.
- Smart Functions:
- DI latch and 32‑bit counter (1 kHz) per input channel.
- DO pulse output and delay output modes.
- Auto‑off timer for digital outputs.
- Local DI‑to‑DO mirroring for hardware signal replication.
- Web Server: Embedded HTTP server for remote monitoring and control via standard browsers.
- Software Integration: Compatible with ExpertDAQ Windows Utility, Modbus/TCP OPC servers, and ActiveX/DLL APIs for custom application development.
- Flexible Mounting: DIN‑rail, wall, or stack mounting options.
- Industrial Reliability: Wide operating temperature range (‑25 °C to +75 °C), surge and reverse‑voltage protection, and robust ABS enclosure.
Comprehensive Product Summary – EX9050AB‑MTCP
### 1. Product Overview
Product Name: EX9050AB‑MTCP
Model: EX9050AB‑MTCP
Series: EX9000‑MTCP Ethernet I/O Series
Article Number: EX9050AB‑MTCP
Manufacturer: TOPSCCC / ExpertDAQ (Taiwan)
Product Type: Modbus TCP/IP to Isolated Digital I/O Module
Printed Manual Reference: EX9000‑MTCP User’s Manual, Ethernet I/O Version 2.0 (June 1, 2016)
The EX9050AB‑MTCP is an industrial‑grade Ethernet I/O module designed for distributed digital signal acquisition and control over standard TCP/IP networks. It integrates twelve isolated wet‑contact digital inputs and six isolated open‑collector (NPN) digital outputs, providing seamless Modbus/TCP connectivity for SCADA, PLC, and HMI systems. The module belongs to the EX9000‑MTCP family of Ethernet I/O devices, which share a unified firmware, configuration utility, and web‑based monitoring interface.
### 2. Key Features
- Ethernet Connectivity: 10/100 Mbps auto‑negotiating Ethernet interface (IEEE 802.3/802.3u) with RJ‑45 connector.
- Protocol Support: Native Modbus/TCP server; also supports UDP for broadcast data streaming and event reporting to up to eight hosts.
- Digital I/O Configuration:
- 12 × Isolated Digital Inputs (wet contact, single‑ended, common source/ground).
- 6 × Isolated Digital Outputs (open‑collector NPN type).
- Isolation Protection: 3000 V DC optical isolation between I/O and logic circuits.
- Smart Functions:
- DI latch and 32‑bit counter (1 kHz) per input channel.
- DO pulse output and delay output modes.
- Auto‑off timer for digital outputs.
- Local DI‑to‑DO mirroring for hardware signal replication.
- Web Server: Embedded HTTP server for remote monitoring and control via standard browsers.
- Software Integration: Compatible with ExpertDAQ Windows Utility, Modbus/TCP OPC servers, and ActiveX/DLL APIs for custom application development.
- Flexible Mounting: DIN‑rail, wall, or stack mounting options.
- Industrial Reliability: Wide operating temperature range (‑25 °C to +75 °C), surge and reverse‑voltage protection, and robust ABS enclosure.
### 3. Technical Specifications
Ethernet Interface
- Standards: 10 BASE‑T IEEE 802.3 / 100 BASE‑TX IEEE 802.3u
- Connector: RJ‑45 modular jack
- Cabling: UTP Cat 5 or higher
- Data Rate: Up to 100 Mbps
- Supported Protocols: Modbus/TCP over TCP/IP and UDP
Power Requirements
- Supply Voltage: +10 V DC to +30 V DC (unregulated)
- Typical Consumption: 2 W
- Protection: Over‑voltage and reverse‑polarity protection
Isolation & Protection
- Ethernet Communication Isolation: 1500 V DC
- I/O Isolation: 3000 V DC (optical)
- Surge Strength: per IEC standards
Digital Inputs (DI)
- Channels: 12 (single‑ended, common source/ground)
- Type: Wet contact (logic inversion configurable)
- Logic 0: 0 – 2 V DC max
- Logic 1: 10 – 50 V DC max
- Counter Function: 1 kHz max, 32‑bit + overflow bit
- Input Latch: Supported on all channels
Digital Outputs (DO)
- Channels: 6 (sink type)
- Output Type: Open‑collector NPN
- Load Voltage: Up to 30 V DC
- Load Current: 500 mA max per channel
- Pulse Output: Programmable pulse count and width
Indicators
- Power LED (red)
- Link/Activity LEDs (10/100 Mbps, Tx/Rx, Collision)
Environmental
- Operating Temperature: ‑25 °C to +75 °C
- Storage Temperature: ‑25 °C to +85 °C
- Humidity: 5 – 95 % RH (non‑condensing)
- Atmosphere: No corrosive gases
Mechanical
- Enclosure: ABS plastic with captive mounting hardware
- Terminal Block: Plug‑in screw type, 0.5 – 2.5 mm² (1 × #12 AWG or 2 × #14–22 AWG)
- Mounting: DIN‑rail, wall, or stack mount
### 4. Functionality
The EX9050AB‑MTCP operates as a Modbus/TCP slave (server) on Ethernet networks. Each digital input and output is mapped to Modbus registers and coils, allowing any Modbus‑compliant master (PLC, SCADA, or HMI) to read or write I/O states.
Operation Modes
- Digital Input: Reads wet‑contact signals; can latch transient pulses or count transitions up to 1 kHz.
- Digital Output: Drives external loads or relays; supports direct on/off, pulse generation, and delay timing.
- Mirror Mode: Local DI states can be mirrored automatically to corresponding DO channels for hardware‑level signal duplication.
- Auto‑Off Timer: Configurable timeout to switch outputs off automatically for safety.
Applications
- Remote digital signal acquisition and control
- Machine status monitoring and alarm indication
- Counter and event logging (e.g., flow meters, switches)
- Distributed I/O expansion for PLCs via Ethernet
- Building automation, energy management, and process control
Compatibility
- Works with any Modbus/TCP master device or software.
- Supported by ExpertDAQ Utility, Modbus OPC servers, and third‑party SCADA packages.
- Provides DLL and ActiveX interfaces for integration with Visual Basic, C++, Delphi, and C#.
### 5. Components & Accessories
Included Items
- EX9050AB‑MTCP module
- Plug‑in terminal block connectors
- DIN‑rail mounting clip
- Quick‑start documentation
Optional Accessories
- 24 V DC industrial power supply
- Ethernet cables (Cat 5e/6)
- ExpertDAQ configuration utility (downloadable)
- ActiveX/DLL software libraries
Connectors
- RJ‑45 Ethernet port
- Screw terminals for power (+Vs, GND)
- Screw terminals for DI (COM, DI0–DI11)
- Screw terminals for DO (ISO.GND, DO0–DO5)
### 6. Installation & Setup
System Requirements (for configuration utility)
- IBM‑PC compatible, 486 CPU or higher (Pentium recommended)
- Windows 95/98/2000/NT 4.0 SP3/SP4/XP or later
- 32 MB RAM minimum, 20 MB free disk space
- 10/100 Mbps Ethernet card and hub
- Two Ethernet cables with RJ‑45 connectors
- Power supply +10 – 30 V DC
Wiring Guidelines
- Use continuous wire runs (0.5–2.5 mm²).
- Keep input and output wiring separated from high‑energy lines.
- Avoid sharp bends and minimize cable length.
- Use proper grounding and anti‑static precautions in low‑humidity environments.
Mounting
- Snap onto standard DIN rail or secure to wall/stack using provided hardware.
- Ensure adequate ventilation and protection from vibration and moisture.
Configuration
- Default IP Address: 10.0.0.1
- Subnet Mask: 255.0.0.0
- Gateway: 10.0.0.1
- DHCP: Disabled (by default)
- Web Server: Disabled (by default)
- Module ID: 00
- Password: 00000000
Use the ExpertDAQ Windows Utility to:
1. Search and identify modules on the network.
2. Assign static IP or enable DHCP.
3. Configure DI/DO modes, counters, and pulse parameters.
4. Set watchdog timers, safe values, and power‑on defaults.
5. Test I/O operation interactively.
### 7. Performance & Capabilities
- Data Throughput: Up to 100 Mbps Ethernet transfer rate.
- Counter Frequency: 1 kHz max per DI channel.
- Pulse Output Frequency: Configurable up to 500 Hz (typical).
- Response Time: < 10 ms typical for Modbus transactions.
- Isolation Voltage: 3000 V DC I/O to logic.
- Power‑On Delay: Configurable (0.1 s units).
- Watchdog Timers: Dual (host and module) for fail‑safe operation.
- Reliability: MTBF > 100,000 hours (typical).
Limitations
- Digital input frequency limited to 1 kHz.
- Output current limited to 500 mA per channel.
- No analog I/O capability (digital only).
### 8. Standards & Compliance
- Communication Standards: IEEE 802.3 / 802.3u Ethernet
- Protocol: Modbus/TCP (Port 502), UDP (Ports 1025 ASCII, 5168 Event/Stream), HTTP (Port 80)
- Isolation & Safety: Optical isolation up to 3000 V DC; over‑voltage and reverse‑polarity protection
- Environmental: Designed for industrial temperature range and humidity tolerance
- EMC Compliance: Meets industrial EMI/ESD immunity requirements (IEC standards)
- RoHS Compliance: Lead‑free construction per EU Directive
- Quality System: Manufactured under ISO 9001 certified processes
### 9. Additional Information
Firmware & Software
- Built‑in Modbus/TCP server firmware with ASCII command support.
- Supports ActiveX (TCPDAQ.OCX) and DLL (TCPDAQ.DLL) APIs for custom software integration.
- Example projects available for Visual Basic, Delphi, Visual C++, and Borland C++ Builder.
- Web server interface for real‑time I/O monitoring and control.
Watchdog Functions
- Module Watchdog: Hardware reset circuit to recover from system hangs.
- Host Watchdog: Software timer monitors communication from host; on timeout, outputs switch to safe state.
Power‑On and Safe Values
- User‑definable output states at power‑up and on watchdog timeout.
- Configurable via ASCII commands (~AA4V, ~AA5V).
Maintenance & Calibration
- No periodic calibration required for digital modules.
- Regularly inspect terminal connections and clean with dry air.
- Firmware updates available from TOPSCCC website (www.topsccc.com.tw).
Warranty & Support
- Standard manufacturer warranty (typically 2 years against defects).
- Technical support and firmware updates available through TOPSCCC support portal.
- Comprehensive user manual and utility software downloadable from manufacturer’s website.
### Summary
The EX9050AB‑MTCP is a compact, high‑isolation Ethernet digital I/O module optimized for industrial automation and remote data acquisition. With twelve wet‑contact digital inputs, six open‑collector outputs, Modbus/TCP and UDP support, and integrated web and software tools, it provides a reliable, flexible interface between field devices and Ethernet‑based control systems. Its robust electrical isolation, configurable watchdogs, and wide environmental tolerance make it suitable for demanding industrial, building, and process‑control applications.
### 1. Product Overview
Product Name: EX9050AB‑MTCP
Model: EX9050AB‑MTCP
Series: EX9000‑MTCP Ethernet I/O Series
Article Number: EX9050AB‑MTCP
Manufacturer: TOPSCCC / ExpertDAQ (Taiwan)
Product Type: Modbus TCP/IP to Isolated Digital I/O Module
Printed Manual Reference: EX9000‑MTCP User’s Manual, Ethernet I/O Version 2.0 (June 1, 2016)
The EX9050AB‑MTCP is an industrial‑grade Ethernet I/O module designed for distributed digital signal acquisition and control over standard TCP/IP networks. It integrates twelve isolated wet‑contact digital inputs and six isolated open‑collector (NPN) digital outputs, providing seamless Modbus/TCP connectivity for SCADA, PLC, and HMI systems. The module belongs to the EX9000‑MTCP family of Ethernet I/O devices, which share a unified firmware, configuration utility, and web‑based monitoring interface.
### 2. Key Features
- Ethernet Connectivity: 10/100 Mbps auto‑negotiating Ethernet interface (IEEE 802.3/802.3u) with RJ‑45 connector.
- Protocol Support: Native Modbus/TCP server; also supports UDP for broadcast data streaming and event reporting to up to eight hosts.
- Digital I/O Configuration:
- 12 × Isolated Digital Inputs (wet contact, single‑ended, common source/ground).
- 6 × Isolated Digital Outputs (open‑collector NPN type).
- Isolation Protection: 3000 V DC optical isolation between I/O and logic circuits.
- Smart Functions:
- DI latch and 32‑bit counter (1 kHz) per input channel.
- DO pulse output and delay output modes.
- Auto‑off timer for digital outputs.
- Local DI‑to‑DO mirroring for hardware signal replication.
- Web Server: Embedded HTTP server for remote monitoring and control via standard browsers.
- Software Integration: Compatible with ExpertDAQ Windows Utility, Modbus/TCP OPC servers, and ActiveX/DLL APIs for custom application development.
- Flexible Mounting: DIN‑rail, wall, or stack mounting options.
- Industrial Reliability: Wide operating temperature range (‑25 °C to +75 °C), surge and reverse‑voltage protection, and robust ABS enclosure.
### 3. Technical Specifications
Ethernet Interface
- Standards: 10 BASE‑T IEEE 802.3 / 100 BASE‑TX IEEE 802.3u
- Connector: RJ‑45 modular jack
- Cabling: UTP Cat 5 or higher
- Data Rate: Up to 100 Mbps
- Supported Protocols: Modbus/TCP over TCP/IP and UDP
Power Requirements
- Supply Voltage: +10 V DC to +30 V DC (unregulated)
- Typical Consumption: 2 W
- Protection: Over‑voltage and reverse‑polarity protection
Isolation & Protection
- Ethernet Communication Isolation: 1500 V DC
- I/O Isolation: 3000 V DC (optical)
- Surge Strength: per IEC standards
Digital Inputs (DI)
- Channels: 12 (single‑ended, common source/ground)
- Type: Wet contact (logic inversion configurable)
- Logic 0: 0 – 2 V DC max
- Logic 1: 10 – 50 V DC max
- Counter Function: 1 kHz max, 32‑bit + overflow bit
- Input Latch: Supported on all channels
Digital Outputs (DO)
- Channels: 6 (sink type)
- Output Type: Open‑collector NPN
- Load Voltage: Up to 30 V DC
- Load Current: 500 mA max per channel
- Pulse Output: Programmable pulse count and width
Indicators
- Power LED (red)
- Link/Activity LEDs (10/100 Mbps, Tx/Rx, Collision)
Environmental
- Operating Temperature: ‑25 °C to +75 °C
- Storage Temperature: ‑25 °C to +85 °C
- Humidity: 5 – 95 % RH (non‑condensing)
- Atmosphere: No corrosive gases
Mechanical
- Enclosure: ABS plastic with captive mounting hardware
- Terminal Block: Plug‑in screw type, 0.5 – 2.5 mm² (1 × #12 AWG or 2 × #14–22 AWG)
- Mounting: DIN‑rail, wall, or stack mount
### 4. Functionality
The EX9050AB‑MTCP operates as a Modbus/TCP slave (server) on Ethernet networks. Each digital input and output is mapped to Modbus registers and coils, allowing any Modbus‑compliant master (PLC, SCADA, or HMI) to read or write I/O states.
Operation Modes
- Digital Input: Reads wet‑contact signals; can latch transient pulses or count transitions up to 1 kHz.
- Digital Output: Drives external loads or relays; supports direct on/off, pulse generation, and delay timing.
- Mirror Mode: Local DI states can be mirrored automatically to corresponding DO channels for hardware‑level signal duplication.
- Auto‑Off Timer: Configurable timeout to switch outputs off automatically for safety.
Applications
- Remote digital signal acquisition and control
- Machine status monitoring and alarm indication
- Counter and event logging (e.g., flow meters, switches)
- Distributed I/O expansion for PLCs via Ethernet
- Building automation, energy management, and process control
Compatibility
- Works with any Modbus/TCP master device or software.
- Supported by ExpertDAQ Utility, Modbus OPC servers, and third‑party SCADA packages.
- Provides DLL and ActiveX interfaces for integration with Visual Basic, C++, Delphi, and C#.
### 5. Components & Accessories
Included Items
- EX9050AB‑MTCP module
- Plug‑in terminal block connectors
- DIN‑rail mounting clip
- Quick‑start documentation
Optional Accessories
- 24 V DC industrial power supply
- Ethernet cables (Cat 5e/6)
- ExpertDAQ configuration utility (downloadable)
- ActiveX/DLL software libraries
Connectors
- RJ‑45 Ethernet port
- Screw terminals for power (+Vs, GND)
- Screw terminals for DI (COM, DI0–DI11)
- Screw terminals for DO (ISO.GND, DO0–DO5)
### 6. Installation & Setup
System Requirements (for configuration utility)
- IBM‑PC compatible, 486 CPU or higher (Pentium recommended)
- Windows 95/98/2000/NT 4.0 SP3/SP4/XP or later
- 32 MB RAM minimum, 20 MB free disk space
- 10/100 Mbps Ethernet card and hub
- Two Ethernet cables with RJ‑45 connectors
- Power supply +10 – 30 V DC
Wiring Guidelines
- Use continuous wire runs (0.5–2.5 mm²).
- Keep input and output wiring separated from high‑energy lines.
- Avoid sharp bends and minimize cable length.
- Use proper grounding and anti‑static precautions in low‑humidity environments.
Mounting
- Snap onto standard DIN rail or secure to wall/stack using provided hardware.
- Ensure adequate ventilation and protection from vibration and moisture.
Configuration
- Default IP Address: 10.0.0.1
- Subnet Mask: 255.0.0.0
- Gateway: 10.0.0.1
- DHCP: Disabled (by default)
- Web Server: Disabled (by default)
- Module ID: 00
- Password: 00000000
Use the ExpertDAQ Windows Utility to:
1. Search and identify modules on the network.
2. Assign static IP or enable DHCP.
3. Configure DI/DO modes, counters, and pulse parameters.
4. Set watchdog timers, safe values, and power‑on defaults.
5. Test I/O operation interactively.
### 7. Performance & Capabilities
- Data Throughput: Up to 100 Mbps Ethernet transfer rate.
- Counter Frequency: 1 kHz max per DI channel.
- Pulse Output Frequency: Configurable up to 500 Hz (typical).
- Response Time: < 10 ms typical for Modbus transactions.
- Isolation Voltage: 3000 V DC I/O to logic.
- Power‑On Delay: Configurable (0.1 s units).
- Watchdog Timers: Dual (host and module) for fail‑safe operation.
- Reliability: MTBF > 100,000 hours (typical).
Limitations
- Digital input frequency limited to 1 kHz.
- Output current limited to 500 mA per channel.
- No analog I/O capability (digital only).
### 8. Standards & Compliance
- Communication Standards: IEEE 802.3 / 802.3u Ethernet
- Protocol: Modbus/TCP (Port 502), UDP (Ports 1025 ASCII, 5168 Event/Stream), HTTP (Port 80)
- Isolation & Safety: Optical isolation up to 3000 V DC; over‑voltage and reverse‑polarity protection
- Environmental: Designed for industrial temperature range and humidity tolerance
- EMC Compliance: Meets industrial EMI/ESD immunity requirements (IEC standards)
- RoHS Compliance: Lead‑free construction per EU Directive
- Quality System: Manufactured under ISO 9001 certified processes
### 9. Additional Information
Firmware & Software
- Built‑in Modbus/TCP server firmware with ASCII command support.
- Supports ActiveX (TCPDAQ.OCX) and DLL (TCPDAQ.DLL) APIs for custom software integration.
- Example projects available for Visual Basic, Delphi, Visual C++, and Borland C++ Builder.
- Web server interface for real‑time I/O monitoring and control.
Watchdog Functions
- Module Watchdog: Hardware reset circuit to recover from system hangs.
- Host Watchdog: Software timer monitors communication from host; on timeout, outputs switch to safe state.
Power‑On and Safe Values
- User‑definable output states at power‑up and on watchdog timeout.
- Configurable via ASCII commands (~AA4V, ~AA5V).
Maintenance & Calibration
- No periodic calibration required for digital modules.
- Regularly inspect terminal connections and clean with dry air.
- Firmware updates available from TOPSCCC website (www.topsccc.com.tw).
Warranty & Support
- Standard manufacturer warranty (typically 2 years against defects).
- Technical support and firmware updates available through TOPSCCC support portal.
- Comprehensive user manual and utility software downloadable from manufacturer’s website.
### Summary
The EX9050AB‑MTCP is a compact, high‑isolation Ethernet digital I/O module optimized for industrial automation and remote data acquisition. With twelve wet‑contact digital inputs, six open‑collector outputs, Modbus/TCP and UDP support, and integrated web and software tools, it provides a reliable, flexible interface between field devices and Ethernet‑based control systems. Its robust electrical isolation, configurable watchdogs, and wide environmental tolerance make it suitable for demanding industrial, building, and process‑control applications.
Kein Zubehör vorhanden.