  • The ORing IDS‑312 is a compact, industrial‑grade redundant device server designed to bridge serial communication interfaces (RS‑232/422/485) with Ethernet networks. It provides two 10/100Base‑T(X) LAN ports and one serial port, enabling reliable and secure serial‑to‑Ethernet data conversion in mission‑critical industrial environments. The device supports redundant Ethernet paths with recovery times under 10 ms, redundant DC power inputs, and a robust IP‑30 metal enclosure suitable for DIN‑rail or wall mounting.
- Redundant Ethernet Connectivity:
Two 10/100Base‑T(X) ports with auto MDI/MDI‑X support ensure network redundancy and fast recovery (< 10 ms) in case of link failure.

- Versatile Serial Interface:
One DB9 serial port configurable for RS‑232, RS‑422, or RS‑485 (2‑wire/4‑wire) operation, supporting baud rates from 110 bps to 460.8 Kbps.

- Multiple Operation Modes:
Supports Virtual COM, Serial Tunnel, TCP Server, TCP Client, and UDP modes for flexible integration with diverse network architectures.

- High Security:
Incorporates HTTPS, SSH, and SSL encryption, IP access control, and IP whitelisting to safeguard data transmission.

- Comprehensive Event Notification:
System events can trigger alerts via Syslog, Email, SNMP trap, relay output, or audible beeper.

- Redundant Power Inputs:
Dual 12–48 VDC inputs on a 6‑pin terminal block with overload and reverse polarity protection.

- Industrial‑Grade Design:
IP‑30 metal housing, wide operating temperature range (‑40 °C to 70 °C), and vibration/shock resistance per IEC60068 standards.

- Ease of Management:
Configurable via Web interface, Windows DS‑Tool utility, Telnet, or SSH console. Supports firmware upgrades and configuration backup/restore.

- PoE Option (IDS‑312+):
The “+” variant includes IEEE 802.3af‑compliant Power‑over‑Ethernet (PD) capability on Ethernet port 1.

- Software Utility (DS‑Tool):
Windows‑based configuration and monitoring tool supporting device discovery, group setup, firmware updates, and Virtual COM mapping.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8517 6200 900

Comprehensive Product Summary – ORing IDS‑312 Industrial Redundant Device Server




### 1. Product Overview

Product Name: IDS‑312
Model: IDS‑312
Series: IDS‑312/322/342(+) Industrial Device Server Series
Article Number: IDS‑312
Manufacturer: ORing Industrial Networking Corp.
Manufacturer Website: [www.oring-networking.com](http://www.oring-networking.com)
Support Contact: support@oring-networking.com
Sales Contact: sales@oring-networking.com

The ORing IDS‑312 is a compact, industrial‑grade redundant device server designed to bridge serial communication interfaces (RS‑232/422/485) with Ethernet networks. It provides two 10/100Base‑T(X) LAN ports and one serial port, enabling reliable and secure serial‑to‑Ethernet data conversion in mission‑critical industrial environments. The device supports redundant Ethernet paths with recovery times under 10 ms, redundant DC power inputs, and a robust IP‑30 metal enclosure suitable for DIN‑rail or wall mounting.




### 2. Key Features

- Redundant Ethernet Connectivity:
Two 10/100Base‑T(X) ports with auto MDI/MDI‑X support ensure network redundancy and fast recovery (< 10 ms) in case of link failure.

- Versatile Serial Interface:
One DB9 serial port configurable for RS‑232, RS‑422, or RS‑485 (2‑wire/4‑wire) operation, supporting baud rates from 110 bps to 460.8 Kbps.

- Multiple Operation Modes:
Supports Virtual COM, Serial Tunnel, TCP Server, TCP Client, and UDP modes for flexible integration with diverse network architectures.

- High Security:
Incorporates HTTPS, SSH, and SSL encryption, IP access control, and IP whitelisting to safeguard data transmission.

- Comprehensive Event Notification:
System events can trigger alerts via Syslog, Email, SNMP trap, relay output, or audible beeper.

- Redundant Power Inputs:
Dual 12–48 VDC inputs on a 6‑pin terminal block with overload and reverse polarity protection.

- Industrial‑Grade Design:
IP‑30 metal housing, wide operating temperature range (‑40 °C to 70 °C), and vibration/shock resistance per IEC60068 standards.

- Ease of Management:
Configurable via Web interface, Windows DS‑Tool utility, Telnet, or SSH console. Supports firmware upgrades and configuration backup/restore.

- PoE Option (IDS‑312+):
The “+” variant includes IEEE 802.3af‑compliant Power‑over‑Ethernet (PD) capability on Ethernet port 1.

- Software Utility (DS‑Tool):
Windows‑based configuration and monitoring tool supporting device discovery, group setup, firmware updates, and Virtual COM mapping.




### 3. Technical Specifications

Network Interfaces:
- 2 × 10/100Base‑T(X) RJ‑45 ports, auto MDI/MDI‑X
- PoE PD (IEEE 802.3af) on ETH1 (IDS‑312+)
- Isolation voltage: 1000 VDC min
- Isolation resistance: 10⁸ Ω min

Serial Interface:
- 1 × DB9 male connector
- Modes: RS‑232/422/485 (2‑wire/4‑wire)
- Baud rate: 110 bps – 460.8 Kbps
- Data bits: 7, 8
- Stop bits: 1, 1.5, 2
- Parity: None, Odd, Even, Mark, Space
- Flow control: XON/XOFF, RTS/CTS, DTR/DSR
- RS‑232 signals: TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND

Network Protocols Supported:
ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP v1/v2c, HTTPS, SMTP

LED Indicators:
- PWR1/PWR2/PoE: Green – Power ON
- ETH1/ETH2: Green – Link/Activity @ 100 Mbps
- TX/RX: Green – Transmit / Red – Receive

Power:
- Dual DC inputs: 12–48 VDC via 6‑pin terminal block
- Power consumption: 3.36 W (typical)
- Overload and reverse polarity protection

Physical Characteristics:
- Enclosure: IP‑30 metal case
- Dimensions: 45 (W) × 81 (D) × 95 (H) mm
- Weight: 304 g (IDS‑312), 313 g (IDS‑312+)
- Mounting: DIN‑rail or wall mount

Environmental:
- Operating temperature: ‑40 °C to 70 °C (‑40 °F to 158 °F)
- Storage temperature: ‑40 °C to 85 °C (‑40 °F to 185 °F)
- Humidity: 5 % – 95 %, non‑condensing

Regulatory Approvals:
- EMI: FCC Part 15, CISPR (EN55022) Class A
- EMS: EN61000‑4‑2 (ESD), ‑4‑3 (RS), ‑4‑4 (EFT), ‑4‑5 (Surge), ‑4‑6 (CS), ‑4‑8, ‑4‑11
- Shock: IEC60068‑2‑27
- Vibration: IEC60068‑2‑6
- Free Fall: IEC60068‑2‑32
- Safety: EN60950‑1

Warranty: 5 years




### 4. Functionality

The IDS‑312 functions as a serial‑to‑Ethernet converter, enabling legacy serial devices to communicate over modern IP networks. It supports multiple communication modes:

- Virtual COM Mode:
Maps the serial port to a virtual COM port on a host PC, allowing transparent communication as if directly connected. Supports up to 5 simultaneous host connections.

- TCP Server Mode:
The device listens on a defined TCP port and accepts incoming connections from up to 5 clients simultaneously.

- TCP Client Mode:
Initiates a TCP connection to a remote host either at startup or upon data transmission.

- UDP Mode:
Enables unicast or multicast data transmission for low‑latency applications.

- Serial Tunnel Mode:
Creates a transparent serial link between two device servers over Ethernet.

Use Cases:
- Industrial automation and SCADA systems
- Remote monitoring of PLCs, sensors, and meters
- Serial device networking in transportation, energy, and manufacturing sectors
- Redundant communication links for critical control systems

Compatibility:
- Supported OS for DS‑Tool and Virtual COM driver: Windows NT/2000/XP/2003/Vista (32/64 bit), Windows 7 (32/64 bit)
- Linux systems supported via fixed TTY driver




### 5. Components & Accessories

Included Items:
- IDS‑312 device server unit
- DIN‑rail mounting kit
- Wall‑mount brackets (for IDS‑312/322 models)
- Quick installation guide
- Terminal block connector

Optional Accessories:
- Power supply (12–48 VDC external adapter)
- Ethernet cables (Cat 5/5e UTP)
- DB9 serial cables (RS‑232/422/485)

Connectors:
- Ethernet: RJ‑45 × 2
- Serial: DB9 male × 1
- Power/Relay: 6‑pin terminal block (PWR1, PWR2, Relay)
- Grounding: Dedicated ground screw




### 6. Installation & Setup

Mounting Options:
- DIN‑Rail Installation: Attach the included DIN‑rail kit to the rear panel and snap onto a standard DIN‑rail.
- Wall Mounting: Use the provided L‑shaped brackets and screws to secure the unit to a wall or panel.

Wiring Guidelines:
- Disconnect power before wiring.
- Use separate routing for power and signal cables to minimize EMI.
- Ground the device properly before connecting power.
- Power input wiring: V+ and V‑ to PWR1/PWR2 terminals; tighten clamps securely.

Ethernet Cabling:
- 10BASE‑T: Cat 3/4/5 UTP, 100 m max
- 100BASE‑TX: Cat 5/5e UTP, 100 m max
- Supports auto MDI/MDI‑X

Serial Connection:
- DB9 pin assignments support RS‑232/422/485 modes.
- Configure interface type via software settings.

Configuration Methods:
1. DS‑Tool Utility: Discover devices, assign IPs, configure serial ports, and update firmware.
2. Web Interface: Access via browser (default IP 192.168.10.2 or 192.168.10.1).
3. Telnet/SSH Console: Command‑line configuration and diagnostics.
4. SNMP Management: Monitor device status and receive traps.




### 7. Performance & Capabilities

- Ethernet Redundancy: Automatic failover with recovery < 10 ms.
- Serial Throughput: Up to 460.8 Kbps per port.
- Simultaneous Connections: Up to 5 hosts per serial port.
- Data Buffer: 4 KB per port with configurable flush intervals and delimiters.
- QoS Management: Application‑based prioritization for critical data.
- Event Handling: Hardware and software resets, login failures, IP changes, and port status changes trigger notifications.
- Reliability: Redundant power and network paths ensure continuous operation in harsh environments.
- Limitations: Single serial port (IDS‑312); for higher port density, IDS‑322 (2 ports) or IDS‑342 (4 ports) models are available.




### 8. Standards & Compliance

Electrical & Safety:
- EN60950‑1 Safety Standard
- IEEE 802.3 and 802.3u Ethernet Compliance
- IEEE 802.3af PoE PD (IDS‑312+)

EMC/EMI:
- FCC Part 15 Class A
- EN55022 Class A (CISPR)

Immunity (EMS):
- EN61000‑4‑2 Electrostatic Discharge
- EN61000‑4‑3 Radiated Susceptibility
- EN61000‑4‑4 Electrical Fast Transient
- EN61000‑4‑5 Surge Immunity
- EN61000‑4‑6 Conducted Susceptibility
- EN61000‑4‑8 Power Frequency Magnetic Field
- EN61000‑4‑11 Voltage Dips and Interruptions

Environmental & Mechanical:
- IEC60068‑2‑27 Shock
- IEC60068‑2‑6 Vibration
- IEC60068‑2‑32 Free Fall

Ingress Protection: IP‑30




### 9. Additional Information

Warranty:
5‑year limited warranty covering defects in materials and workmanship. Excludes damage from misuse, improper installation, or unauthorized modifications.

Maintenance:
- Periodically inspect power and network connections.
- Keep ventilation openings clear of dust.
- Firmware updates available via ORing website; upgrade through Web or DS‑Tool interface.

Support & Documentation:
- Comprehensive user manual and configuration guide available online.
- Technical support via email or phone.
- Firmware and software utilities downloadable from ORing’s official site.

Corporate Information:
ORing Industrial Networking Corp.
3F., No. 542‑2, Jhongjheng Rd., Sindian District, New Taipei City 231, Taiwan, R.O.C.
Tel: +886‑2‑2218‑1066 Fax: +886‑2‑2218‑1014




### Summary

The ORing IDS‑312 is a robust, compact industrial device server engineered for reliable serial‑to‑Ethernet communication in demanding environments. With dual redundant Ethernet ports, redundant DC power inputs, and comprehensive management and security features, it ensures continuous operation and data integrity. Its flexible configuration options, wide temperature tolerance, and compliance with international EMC and safety standards make it ideal for industrial automation, transportation, and energy applications requiring dependable serial networking integration.

Kein Zubehör vorhanden.