- PXI and CompactPCI Compatibility: Fully compliant with PXI Specification Rev. 2.2 and PICMG 2.0 CompactPCI standards, supporting both PXI and CompactPCI 3U modules.
- Slot Configuration: One system controller slot and five PXI/CompactPCI peripheral slots, all equipped with PXI trigger, local bus, and 10 MHz reference clock functionality.
- Modular Power Supply: 250 W CompactPCI power module (cPS‑H325/AC) compliant with PICMG 2.11; optional 24 V DC input module (cPS‑H325/24) for mobile or vehicular use.
- Front‑Accessible Power Module: Hot‑swappable, front‑removable PSU design for minimal mean‑time‑to‑repair (MTTR).
- Efficient Cooling: Dual 80 mm × 80 mm × 25 mm ball‑bearing fans providing filtered, forced‑air cooling with removable air filters.
- Mechanical Flexibility: Desk‑top or wall‑mount installation with included mounting kit; IEEE 1101.10 mechanical packaging compliant.
- Environmental Robustness: Designed for industrial environments with wide operating temperature range, vibration tolerance, and shock resistance.
- Electrical Protection: Over‑temperature, over‑current, over‑load, and over‑voltage protection integrated in PSU.
- Mobility and Serviceability: Lightweight (≈ 4.5 kg) aluminum chassis with side handles and stand feet for portability.
- Regulatory Compliance: CE, FCC Class A, EN 60950‑1 safety, EN 55022/55024 EMC compliance.
- Slot Configuration: One system controller slot and five PXI/CompactPCI peripheral slots, all equipped with PXI trigger, local bus, and 10 MHz reference clock functionality.
- Modular Power Supply: 250 W CompactPCI power module (cPS‑H325/AC) compliant with PICMG 2.11; optional 24 V DC input module (cPS‑H325/24) for mobile or vehicular use.
- Front‑Accessible Power Module: Hot‑swappable, front‑removable PSU design for minimal mean‑time‑to‑repair (MTTR).
- Efficient Cooling: Dual 80 mm × 80 mm × 25 mm ball‑bearing fans providing filtered, forced‑air cooling with removable air filters.
- Mechanical Flexibility: Desk‑top or wall‑mount installation with included mounting kit; IEEE 1101.10 mechanical packaging compliant.
- Environmental Robustness: Designed for industrial environments with wide operating temperature range, vibration tolerance, and shock resistance.
- Electrical Protection: Over‑temperature, over‑current, over‑load, and over‑voltage protection integrated in PSU.
- Mobility and Serviceability: Lightweight (≈ 4.5 kg) aluminum chassis with side handles and stand feet for portability.
- Regulatory Compliance: CE, FCC Class A, EN 60950‑1 safety, EN 55022/55024 EMC compliance.
Comprehensive Product Summary – ADLINK PXIS‑2506 PXI/CompactPCI Chassis
### 1. Product Overview
Product Name: PXIS‑2506
Model: PXIS‑2506
Series: PXIS‑25xx PXI/CompactPCI Chassis Series
Article Number: PXIS‑2506
Manufacturer: ADLINK Technology Inc.
Product Type: 6‑Slot 3U PXI/CompactPCI Chassis with 250 W CompactPCI Power Module
Form Factor: 4U Desk/Wall‑Mount Enclosure for 3U PXI/cPCI Cards
Power Input: 100 – 240 VAC, 50 – 60 Hz (optional 24 V DC version PXIS‑2506/DC24)
Intended Use: Bench‑top, wall‑mount, or in‑vehicle PXI test and measurement systems
The ADLINK PXIS‑2506 is a compact, portable PXI/cPCI chassis designed for modular instrumentation, data acquisition, and embedded control applications. It provides one system controller slot and five peripheral slots in a 3U PXI‑compliant backplane, housed in a 4U mechanical enclosure suitable for desktop or wall‑mount installation.
### 2. Key Features
- PXI and CompactPCI Compatibility: Fully compliant with PXI Specification Rev. 2.2 and PICMG 2.0 CompactPCI standards, supporting both PXI and CompactPCI 3U modules.
- Slot Configuration: One system controller slot and five PXI/CompactPCI peripheral slots, all equipped with PXI trigger, local bus, and 10 MHz reference clock functionality.
- Modular Power Supply: 250 W CompactPCI power module (cPS‑H325/AC) compliant with PICMG 2.11; optional 24 V DC input module (cPS‑H325/24) for mobile or vehicular use.
- Front‑Accessible Power Module: Hot‑swappable, front‑removable PSU design for minimal mean‑time‑to‑repair (MTTR).
- Efficient Cooling: Dual 80 mm × 80 mm × 25 mm ball‑bearing fans providing filtered, forced‑air cooling with removable air filters.
- Mechanical Flexibility: Desk‑top or wall‑mount installation with included mounting kit; IEEE 1101.10 mechanical packaging compliant.
- Environmental Robustness: Designed for industrial environments with wide operating temperature range, vibration tolerance, and shock resistance.
- Electrical Protection: Over‑temperature, over‑current, over‑load, and over‑voltage protection integrated in PSU.
- Mobility and Serviceability: Lightweight (≈ 4.5 kg) aluminum chassis with side handles and stand feet for portability.
- Regulatory Compliance: CE, FCC Class A, EN 60950‑1 safety, EN 55022/55024 EMC compliance.
### 3. Technical Specifications
Physical Dimensions:
- Width × Height × Depth: 221 mm × 178 mm × 237 mm (without wall‑mount kit or feet)
- Weight: 4.5 kg (9.9 lb)
Slot Configuration:
- Total Slots: 6 (1 system + 5 peripheral)
- Controller Expansion Slots: 2 (left of system slot)
- Backplane Type: xBP‑3006L PXI backplane + cBP‑3061 PSU backplane
Power Supply (cPS‑H325/AC):
- Form Factor: 3U CompactPCI, 2‑slot (8 HP) width
- Input Voltage: 100 – 240 VAC ± 10 %
- Input Frequency: 50 – 60 Hz ± 5 %
- Input Current: 2.5 A @ 115 VAC / 1.4 A @ 230 VAC
- Output Power: 250 W continuous / 300 W peak
- Output Rails:
- +5 V @ 25 A typ (33 A max)
- +3.3 V @ 18 A typ (33 A max)
- +12 V @ 5 A typ (5.5 A max)
- –12 V @ 0.5 A typ (1 A max)
- Efficiency: ≈ 78 – 79 %
- Hold‑Up Time: ≥ 5 ms after power‑fail signal
- Power Factor Correction: 0.95 – 0.97 (IEC 1000‑3‑2 compliant)
- Protections: OTP (70 °C), OCP, OLP (120 % max load), OVP
- Status Indicators: Green LED = Power OK, Amber LED = Fault
- Earth Leakage: < 0.5 mA @ 230 VAC
Cooling System:
- Fans: 2 × 80 mm × 80 mm × 25 mm ball‑bearing
- Airflow: ≈ 41 – 47 CFM each
- Speed: 3100 ± 250 RPM
- Noise: ≈ 35 dB(A)
- Power: 12 V DC @ 0.20 A each
- Air Filter: Removable, front‑accessible
Environmental Conditions:
- Operating Temperature: 0 °C – 50 °C
- Storage Temperature: –20 °C – 70 °C
- Operating Humidity: 10 % – 90 % RH (non‑condensing)
- Storage Humidity: 5 % – 95 % RH (non‑condensing)
- Shock: 15 G peak‑to‑peak, 11 ms duration
- Vibration: 0.5 G RMS (operating), 1.88 G RMS (non‑operating), 5 – 500 Hz
Backplane Materials:
- PCB Material: UL 94V‑0 rated
- Connectors: IEC‑917 / IEC 1076‑4‑101 compliant
### 4. Functionality
The PXIS‑2506 serves as a modular PXI/cPCI chassis providing mechanical, electrical, and thermal infrastructure for PXI instrumentation modules. It integrates a 6‑slot backplane with one system controller slot (Slot 1) and five peripheral slots (Slots 2–6).
PXI Functional Buses:
- 10 MHz Reference Clock (PXI_CLK10): Buffered and distributed to all peripheral slots with < 1 ns skew.
- Trigger Bus: 8 dedicated trigger lines for inter‑module synchronization.
- Star Trigger Bus: Dedicated trigger routing from Slot 2 (Star Trigger Slot) to Slots 3–6.
- Local Bus: 13‑line daisy‑chained bus between adjacent peripheral slots for high‑speed side‑band communication.
Clock Source Selection:
- Internal 10 MHz (default) or external clock via PXI_CLK10_IN on Star Trigger Slot (P2 connector).
- Configurable via jumpers JP2/JP3.
Use Cases:
- Automated test equipment (ATE)
- Data acquisition and signal analysis
- Industrial measurement and control
- In‑vehicle or mobile PXI systems (with DC power option)
- Research and development instrumentation platforms
Compatibility:
- PXI and CompactPCI 3U modules
- Recommended system controllers: ADLINK PXI‑3710, PXI‑3800 series, PXI‑3900 series
### 5. Components & Accessories
Included Items:
- PXIS‑2506 Chassis with cPS‑H325/AC 250 W Power Supply
- AC Power Cord
- Wall‑mount / Panel‑mount kit (L‑shaped brackets and screws)
- User Manual
Optional Add‑Ons:
- 24 V DC Power Module (cPS‑H325/24)
- OEM custom backplanes and chassis color/logo options
- PXI system controllers (PXI‑3710, PXI‑3800 series)
- Additional cooling fans or filters
Connectors & Interfaces:
- Standard 47‑pin CompactPCI power supply socket (PICMG 2.11)
- ATX‑like power output connectors (CN2)
- Screw terminals for external AC/DC input (CN3)
- SMB (System Management Bus) connector (J5)
- LED power status connector (J8)
- General purpose voltage terminals (J4, J6, J7)
- Control signals: INH#, PRST#, FAL# (J1–J3)
### 6. Installation & Setup
Requirements:
- Stable surface for desk use or suitable mounting panel for wall installation.
- Adequate ventilation clearance beneath and around the chassis.
- AC power source (100–240 VAC) or 24 V DC supply for DC version.
Mounting Options:
1. Wall mount on bottom
2. Wall mount on top
3. Wall mount on system side
4. Wall mount on rear side
Setup Procedure:
1. Ensure rear power switch is OFF.
2. Connect AC power cord to rear inlet.
3. Install system controller module in Slot 1 and secure with screws.
4. Install peripheral modules in Slots 2–6.
5. Turn rear switch ON to energize PSU (amber LED ON).
6. Turn front switch ON to power PXI bus (green LED ON).
7. Verify fan operation and module initialization.
Grounding:
- Mounting holes labeled “GND” connect to logic ground; “FGND” holes are floating for isolation between logic and chassis grounds.
- For isolated applications, remove screws from GND holes.
### 7. Performance & Capabilities
Electrical Performance:
- Continuous output power: 250 W (300 W peak)
- Voltage regulation: ± 1–2 % load regulation, 0.1 % line regulation
- Ripple: 50 mV (+5 V, +3.3 V), 120 mV (+12 V, –12 V)
- Power efficiency: ≈ 79 %
- Hold‑up time: ≥ 5 ms after power fail
- Minimum airflow requirement: ≥ 20 CFM for full load
Thermal & Acoustic Performance:
- Dual fans maintain uniform airflow across modules.
- Noise level ≈ 35 dB(A) at nominal speed.
- Air filter ensures dust‑free operation and easy maintenance.
Mechanical & Environmental Robustness:
- Shock resistance up to 15 G (11 ms)
- Vibration tolerance up to 0.5 G RMS operating
- Operating temperature 0–50 °C without derating
- Suitable for industrial and mobile environments
Limitations:
- Designed for 3U PXI/cPCI modules only (does not support 6U cards).
- Total power draw limited to 250 W continuous.
- Requires adequate ventilation for full load operation at high ambient temperatures.
### 8. Standards & Compliance
PXI/CompactPCI Standards:
- PXI Specification Rev. 2.2 compliant
- CompactPCI Specification PICMG 2.0 compliant
- Power Interface PICMG 2.11 compliant
- IEEE 1101.10 mechanical packaging compliant
Safety & EMC Certifications:
- CE Marking
- FCC Class A (EN 55022 emission standard)
- EN 55024 immunity standard
- EN 60950‑1 safety standard
- IEC 950 and IEC 60950 Class I safety certified
- Harmonic correction per IEC 1000‑3‑2
Environmental & Material Compliance:
- UL 94V‑0 rated backplane materials
- RoHS compliant construction
### 9. Additional Information
Warranty:
- Standard two‑year limited warranty (one year for China).
- Warranty covers manufacturing defects and hardware failures under normal use.
- Exclusions: damage from misuse, improper installation, unauthorized repair, or environmental factors.
- RMA procedure available via ADLINK RMA portal (http://rma.adlinktech.com/policy/).
Maintenance:
- Interior Cleaning: Use dry air or 75 % isopropyl alcohol solution; avoid liquid contact with electronics.
- Exterior Cleaning: Wipe with mild soap solution and lint‑free cloth; do not use abrasives.
- Fan and Filter Service: Fans and filters are field‑replaceable and accessible from front panel.
- Battery Replacement: Lithium RTC battery replaceable by qualified personnel only.
Support & Contact:
ADLINK Technology Inc.
9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan
Tel: +886‑2‑82265877 Fax: +886‑2‑82265717
Email: service@adlinktech.com Web: [www.adlinktech.com](http://www.adlinktech.com)
Safety Notes:
- Disconnect both AC inlets before servicing.
- Operate within specified temperature and humidity limits.
- Avoid liquid ingress and mechanical shock.
- Replace battery only with approved type to prevent explosion risk.
Revision & Documentation:
- User Manual Rev. 1.10 (March 26, 2004)
- Specification update 03‑28‑2012
- All specifications subject to change without notice.
### Summary
The ADLINK PXIS‑2506 is a robust, compact 6‑slot PXI/CompactPCI chassis engineered for high‑performance modular instrumentation. It combines PXI Rev. 2.2 compliance, a 250 W PICMG 2.11 power module, and efficient forced‑air cooling in a lightweight 4U enclosure. Its modular design supports both AC and DC power inputs, making it suitable for bench‑top laboratory use as well as mobile and in‑vehicle applications.
With comprehensive trigger and clock distribution, industrial‑grade power delivery, and broad environmental tolerance, the PXIS‑2506 serves as a reliable foundation for automated test equipment, data acquisition, and embedded control systems requiring PXI or CompactPCI modules.
### 1. Product Overview
Product Name: PXIS‑2506
Model: PXIS‑2506
Series: PXIS‑25xx PXI/CompactPCI Chassis Series
Article Number: PXIS‑2506
Manufacturer: ADLINK Technology Inc.
Product Type: 6‑Slot 3U PXI/CompactPCI Chassis with 250 W CompactPCI Power Module
Form Factor: 4U Desk/Wall‑Mount Enclosure for 3U PXI/cPCI Cards
Power Input: 100 – 240 VAC, 50 – 60 Hz (optional 24 V DC version PXIS‑2506/DC24)
Intended Use: Bench‑top, wall‑mount, or in‑vehicle PXI test and measurement systems
The ADLINK PXIS‑2506 is a compact, portable PXI/cPCI chassis designed for modular instrumentation, data acquisition, and embedded control applications. It provides one system controller slot and five peripheral slots in a 3U PXI‑compliant backplane, housed in a 4U mechanical enclosure suitable for desktop or wall‑mount installation.
### 2. Key Features
- PXI and CompactPCI Compatibility: Fully compliant with PXI Specification Rev. 2.2 and PICMG 2.0 CompactPCI standards, supporting both PXI and CompactPCI 3U modules.
- Slot Configuration: One system controller slot and five PXI/CompactPCI peripheral slots, all equipped with PXI trigger, local bus, and 10 MHz reference clock functionality.
- Modular Power Supply: 250 W CompactPCI power module (cPS‑H325/AC) compliant with PICMG 2.11; optional 24 V DC input module (cPS‑H325/24) for mobile or vehicular use.
- Front‑Accessible Power Module: Hot‑swappable, front‑removable PSU design for minimal mean‑time‑to‑repair (MTTR).
- Efficient Cooling: Dual 80 mm × 80 mm × 25 mm ball‑bearing fans providing filtered, forced‑air cooling with removable air filters.
- Mechanical Flexibility: Desk‑top or wall‑mount installation with included mounting kit; IEEE 1101.10 mechanical packaging compliant.
- Environmental Robustness: Designed for industrial environments with wide operating temperature range, vibration tolerance, and shock resistance.
- Electrical Protection: Over‑temperature, over‑current, over‑load, and over‑voltage protection integrated in PSU.
- Mobility and Serviceability: Lightweight (≈ 4.5 kg) aluminum chassis with side handles and stand feet for portability.
- Regulatory Compliance: CE, FCC Class A, EN 60950‑1 safety, EN 55022/55024 EMC compliance.
### 3. Technical Specifications
Physical Dimensions:
- Width × Height × Depth: 221 mm × 178 mm × 237 mm (without wall‑mount kit or feet)
- Weight: 4.5 kg (9.9 lb)
Slot Configuration:
- Total Slots: 6 (1 system + 5 peripheral)
- Controller Expansion Slots: 2 (left of system slot)
- Backplane Type: xBP‑3006L PXI backplane + cBP‑3061 PSU backplane
Power Supply (cPS‑H325/AC):
- Form Factor: 3U CompactPCI, 2‑slot (8 HP) width
- Input Voltage: 100 – 240 VAC ± 10 %
- Input Frequency: 50 – 60 Hz ± 5 %
- Input Current: 2.5 A @ 115 VAC / 1.4 A @ 230 VAC
- Output Power: 250 W continuous / 300 W peak
- Output Rails:
- +5 V @ 25 A typ (33 A max)
- +3.3 V @ 18 A typ (33 A max)
- +12 V @ 5 A typ (5.5 A max)
- –12 V @ 0.5 A typ (1 A max)
- Efficiency: ≈ 78 – 79 %
- Hold‑Up Time: ≥ 5 ms after power‑fail signal
- Power Factor Correction: 0.95 – 0.97 (IEC 1000‑3‑2 compliant)
- Protections: OTP (70 °C), OCP, OLP (120 % max load), OVP
- Status Indicators: Green LED = Power OK, Amber LED = Fault
- Earth Leakage: < 0.5 mA @ 230 VAC
Cooling System:
- Fans: 2 × 80 mm × 80 mm × 25 mm ball‑bearing
- Airflow: ≈ 41 – 47 CFM each
- Speed: 3100 ± 250 RPM
- Noise: ≈ 35 dB(A)
- Power: 12 V DC @ 0.20 A each
- Air Filter: Removable, front‑accessible
Environmental Conditions:
- Operating Temperature: 0 °C – 50 °C
- Storage Temperature: –20 °C – 70 °C
- Operating Humidity: 10 % – 90 % RH (non‑condensing)
- Storage Humidity: 5 % – 95 % RH (non‑condensing)
- Shock: 15 G peak‑to‑peak, 11 ms duration
- Vibration: 0.5 G RMS (operating), 1.88 G RMS (non‑operating), 5 – 500 Hz
Backplane Materials:
- PCB Material: UL 94V‑0 rated
- Connectors: IEC‑917 / IEC 1076‑4‑101 compliant
### 4. Functionality
The PXIS‑2506 serves as a modular PXI/cPCI chassis providing mechanical, electrical, and thermal infrastructure for PXI instrumentation modules. It integrates a 6‑slot backplane with one system controller slot (Slot 1) and five peripheral slots (Slots 2–6).
PXI Functional Buses:
- 10 MHz Reference Clock (PXI_CLK10): Buffered and distributed to all peripheral slots with < 1 ns skew.
- Trigger Bus: 8 dedicated trigger lines for inter‑module synchronization.
- Star Trigger Bus: Dedicated trigger routing from Slot 2 (Star Trigger Slot) to Slots 3–6.
- Local Bus: 13‑line daisy‑chained bus between adjacent peripheral slots for high‑speed side‑band communication.
Clock Source Selection:
- Internal 10 MHz (default) or external clock via PXI_CLK10_IN on Star Trigger Slot (P2 connector).
- Configurable via jumpers JP2/JP3.
Use Cases:
- Automated test equipment (ATE)
- Data acquisition and signal analysis
- Industrial measurement and control
- In‑vehicle or mobile PXI systems (with DC power option)
- Research and development instrumentation platforms
Compatibility:
- PXI and CompactPCI 3U modules
- Recommended system controllers: ADLINK PXI‑3710, PXI‑3800 series, PXI‑3900 series
### 5. Components & Accessories
Included Items:
- PXIS‑2506 Chassis with cPS‑H325/AC 250 W Power Supply
- AC Power Cord
- Wall‑mount / Panel‑mount kit (L‑shaped brackets and screws)
- User Manual
Optional Add‑Ons:
- 24 V DC Power Module (cPS‑H325/24)
- OEM custom backplanes and chassis color/logo options
- PXI system controllers (PXI‑3710, PXI‑3800 series)
- Additional cooling fans or filters
Connectors & Interfaces:
- Standard 47‑pin CompactPCI power supply socket (PICMG 2.11)
- ATX‑like power output connectors (CN2)
- Screw terminals for external AC/DC input (CN3)
- SMB (System Management Bus) connector (J5)
- LED power status connector (J8)
- General purpose voltage terminals (J4, J6, J7)
- Control signals: INH#, PRST#, FAL# (J1–J3)
### 6. Installation & Setup
Requirements:
- Stable surface for desk use or suitable mounting panel for wall installation.
- Adequate ventilation clearance beneath and around the chassis.
- AC power source (100–240 VAC) or 24 V DC supply for DC version.
Mounting Options:
1. Wall mount on bottom
2. Wall mount on top
3. Wall mount on system side
4. Wall mount on rear side
Setup Procedure:
1. Ensure rear power switch is OFF.
2. Connect AC power cord to rear inlet.
3. Install system controller module in Slot 1 and secure with screws.
4. Install peripheral modules in Slots 2–6.
5. Turn rear switch ON to energize PSU (amber LED ON).
6. Turn front switch ON to power PXI bus (green LED ON).
7. Verify fan operation and module initialization.
Grounding:
- Mounting holes labeled “GND” connect to logic ground; “FGND” holes are floating for isolation between logic and chassis grounds.
- For isolated applications, remove screws from GND holes.
### 7. Performance & Capabilities
Electrical Performance:
- Continuous output power: 250 W (300 W peak)
- Voltage regulation: ± 1–2 % load regulation, 0.1 % line regulation
- Ripple: 50 mV (+5 V, +3.3 V), 120 mV (+12 V, –12 V)
- Power efficiency: ≈ 79 %
- Hold‑up time: ≥ 5 ms after power fail
- Minimum airflow requirement: ≥ 20 CFM for full load
Thermal & Acoustic Performance:
- Dual fans maintain uniform airflow across modules.
- Noise level ≈ 35 dB(A) at nominal speed.
- Air filter ensures dust‑free operation and easy maintenance.
Mechanical & Environmental Robustness:
- Shock resistance up to 15 G (11 ms)
- Vibration tolerance up to 0.5 G RMS operating
- Operating temperature 0–50 °C without derating
- Suitable for industrial and mobile environments
Limitations:
- Designed for 3U PXI/cPCI modules only (does not support 6U cards).
- Total power draw limited to 250 W continuous.
- Requires adequate ventilation for full load operation at high ambient temperatures.
### 8. Standards & Compliance
PXI/CompactPCI Standards:
- PXI Specification Rev. 2.2 compliant
- CompactPCI Specification PICMG 2.0 compliant
- Power Interface PICMG 2.11 compliant
- IEEE 1101.10 mechanical packaging compliant
Safety & EMC Certifications:
- CE Marking
- FCC Class A (EN 55022 emission standard)
- EN 55024 immunity standard
- EN 60950‑1 safety standard
- IEC 950 and IEC 60950 Class I safety certified
- Harmonic correction per IEC 1000‑3‑2
Environmental & Material Compliance:
- UL 94V‑0 rated backplane materials
- RoHS compliant construction
### 9. Additional Information
Warranty:
- Standard two‑year limited warranty (one year for China).
- Warranty covers manufacturing defects and hardware failures under normal use.
- Exclusions: damage from misuse, improper installation, unauthorized repair, or environmental factors.
- RMA procedure available via ADLINK RMA portal (http://rma.adlinktech.com/policy/).
Maintenance:
- Interior Cleaning: Use dry air or 75 % isopropyl alcohol solution; avoid liquid contact with electronics.
- Exterior Cleaning: Wipe with mild soap solution and lint‑free cloth; do not use abrasives.
- Fan and Filter Service: Fans and filters are field‑replaceable and accessible from front panel.
- Battery Replacement: Lithium RTC battery replaceable by qualified personnel only.
Support & Contact:
ADLINK Technology Inc.
9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan
Tel: +886‑2‑82265877 Fax: +886‑2‑82265717
Email: service@adlinktech.com Web: [www.adlinktech.com](http://www.adlinktech.com)
Safety Notes:
- Disconnect both AC inlets before servicing.
- Operate within specified temperature and humidity limits.
- Avoid liquid ingress and mechanical shock.
- Replace battery only with approved type to prevent explosion risk.
Revision & Documentation:
- User Manual Rev. 1.10 (March 26, 2004)
- Specification update 03‑28‑2012
- All specifications subject to change without notice.
### Summary
The ADLINK PXIS‑2506 is a robust, compact 6‑slot PXI/CompactPCI chassis engineered for high‑performance modular instrumentation. It combines PXI Rev. 2.2 compliance, a 250 W PICMG 2.11 power module, and efficient forced‑air cooling in a lightweight 4U enclosure. Its modular design supports both AC and DC power inputs, making it suitable for bench‑top laboratory use as well as mobile and in‑vehicle applications.
With comprehensive trigger and clock distribution, industrial‑grade power delivery, and broad environmental tolerance, the PXIS‑2506 serves as a reliable foundation for automated test equipment, data acquisition, and embedded control systems requiring PXI or CompactPCI modules.
-
PXIS-2506_Datasheet_en_1.pdf
PDF Catalog
-
PXIS-2506_Datasheet_5.pdf
PDF Catalog
-
PXIS-2506_Manual_4.pdf
Manual
Kein Zubehör vorhanden.