SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

Produktsuche

5416 Treffer

Code Produkt Preis Menge
5B module RTD Pt 100 2/3/4L 0°..+200°C in, 0-5V out 5B34-03
5B module RTD Pt 100 2/3/4L 0°..+200°C in, 0-5V out

- **RTD Input Compatibility:** Accepts **Pt100** platinum RTDs with 2-, 3-, or 4-wire connections, ensuring flexibility in wiring and compensation for lead resistance. - **Temperature Range:** Measures temperatures from **0°C to +200°C**, suitable for a wide range of industrial and laboratory environments. - **Linearized Output:** Provides a **0–5 VDC** analog output signal proportional to the measured temperature, simplifying interface with analog input channels. - **High Accuracy and Stability:** Factory-calibrated for precise temperature-to-voltage conversion with minimal drift over time and temperature. - **Galvanic Isolation:** Typical 1500 VDC isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Compact Form Factor:** Designed for use in 5B Series backplanes or DIN-rail carriers, allowing high-density installation. - **Plug-and-Play Integration:** Compatible with standard 5B backplanes and data acquisition systems, enabling modular expansion. - **Low Power Consumption:** Optimized for low current draw, suitable for multi-channel systems. - **Rugged Industrial Design:** Encapsulated construction for vibration resistance and long-term reliability.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module RTD Pt 100 2/3/4L 0°..+600°C in, 0-5V out 5B34-04
5B module RTD Pt 100 2/3/4L 0°..+600°C in, 0-5V out

- **RTD Input Compatibility:** Designed for **Pt100 platinum RTDs**, supporting 2-, 3-, and 4-wire connections for flexible installation and compensation of lead resistance. - **Wide Temperature Range:** Measures temperatures from **0°C to +600°C**, suitable for industrial process monitoring, laboratory instrumentation, and environmental control systems. - **Standardized Voltage Output:** Provides a **0 to +5 V** analog output proportional to the input temperature, compatible with most analog input modules, data acquisition systems, and controllers. - **High Accuracy and Stability:** Factory-calibrated for precise linearization of the Pt100 sensor curve, ensuring accurate temperature representation across the full measurement range. - **Electrical Isolation:** Incorporates **1500 V rms isolation** (typical for 5B modules) between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Compact Modular Design:** Housed in a compact plug-in module format compatible with 5B Series backplanes and mounting racks. - **Low Power Consumption:** Designed for efficient operation from a single +5 V supply, minimizing system power requirements. - **Rugged Industrial Construction:** Built for reliable operation in demanding environments, with robust encapsulation and high immunity to electromagnetic interference (EMI). - **Ease of Integration:** Standardized pinout and mechanical form factor ensure compatibility with existing 5B Series carriers and accessories.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement B 0°..+1800°C in, 0-5V out 5B37-B05
5B module Thermoelement B 0°..+1800°C in, 0-5V out

- **Thermocouple Input Type:** Type B (Platinum-Rhodium / Platinum thermocouple) - **Input Range:** 0°C to +1800°C - **Output Range:** 0 to +5 V DC - **Non-linearized Output:** Provides a direct, uncorrected voltage proportional to the thermocouple’s millivolt signal, scaled to the specified output range. - **High Electrical Isolation:** Galvanic isolation between input, output, and power supply, typically rated at 1500 V rms or higher, ensuring protection against ground loops and electrical noise. - **Compact 5B Form Factor:** Standardized plug-in module compatible with 5B backplanes and carriers. - **High Accuracy and Stability:** Designed for precision temperature measurement and signal conditioning in demanding environments. - **Low Power Consumption:** Optimized for multi-channel data acquisition systems. - **Rugged Industrial Design:** Suitable for use in harsh environments, with robust construction and reliable performance. - **Ease of Integration:** Compatible with a wide range of data acquisition systems, PLCs, and analog input modules.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement E 0°..+900°C in, 0-5V out 5B37-E04
5B module Thermoelement E 0°..+900°C in, 0-5V out

- **Thermocouple Input Type:** Type E (Chromel-Constantan) - **Input Range:** 0°C to +900°C - **Output Range:** 0 to +5 V DC - **Non-linearized Output:** Provides direct proportional voltage output without internal linearization, allowing external software or hardware linearization if required. - **High Accuracy Signal Conditioning:** Designed for precise thermocouple signal amplification and scaling. - **Electrical Isolation:** Typical of 5B modules, offering 1500 V RMS isolation between input, output, and power to protect data acquisition systems from ground loops and electrical noise. - **Compact Modular Design:** Standard 5B form factor for easy integration into backplanes and mounting racks. - **Cold Junction Compensation (CJC):** Typically integrated in 5B thermocouple modules to ensure accurate temperature measurement by compensating for reference junction temperature variations. - **Plug-and-Play Compatibility:** Designed for use with 5B Series backplanes and carriers, enabling quick installation and replacement. - **Industrial Reliability:** Rugged design suitable for harsh environments, with wide operating temperature range and robust electrical characteristics.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement E, 0°..+1000°C in, 0-5V out 5B47-E08
5B module Thermoelement E, 0°..+1000°C in, 0-5V out

- **Thermocouple Type:** Type E (Chromel-Constantan) - **Input Range:** 0°C to +1000°C - **Output Range:** 0 to +5 V DC (linearized) - **Linearization:** Internal cold-junction compensation and linearization for Type E thermocouples - **High Accuracy:** Factory-calibrated for precise temperature-to-voltage conversion - **Electrical Isolation:** 1500 V RMS isolation between input, output, and power - **Low Noise:** Designed for low drift and high signal integrity in noisy industrial environments - **Compact Form Factor:** Standard 5B module size for plug-in installation - **Plug-and-Play Compatibility:** Fits standard 5B backplanes and carriers - **Wide Operating Temperature Range:** Suitable for industrial temperature conditions - **Rugged Construction:** Encapsulated design for protection against vibration, humidity, and contaminants - **Ease of Integration:** Standardized pinout and output scaling for direct connection to analog input channels of data acquisition systems

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement J -100°..+760°C in, 0-5V out 5B37-J01
5B module Thermoelement J -100°..+760°C in, 0-5V out

- **Thermocouple Type J Input:** Designed specifically for iron–constantan (Type J) thermocouples, covering a wide temperature range from –100°C to +760°C. - **Non-linearized Output:** Provides a direct, uncorrected voltage output proportional to the thermocouple’s natural response curve, allowing external linearization or software compensation. - **Standardized Output Signal:** Converts the thermocouple input to a **0–5 V DC output**, compatible with most analog input channels, data acquisition systems, and PLCs. - **High Common-Mode Isolation:** Typical 1500 V RMS isolation between input, output, and power, ensuring signal integrity and protection against ground loops. - **Compact 5B Form Factor:** Standardized plug-in module compatible with 5B backplanes and carriers, enabling easy integration and replacement. - **Low Noise and High Accuracy:** Engineered for precision measurement applications, minimizing thermal drift and electrical interference. - **Wide Operating Range:** Suitable for industrial environments with extended temperature and humidity tolerance. - **Ease of Integration:** Designed for use with 5B Series backplanes, providing screw-terminal or plug-in connectivity for thermocouple leads and output wiring. - **Rugged Construction:** Encapsulated module design for mechanical stability and environmental protection.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement J,  -100°..+300°C in, 0-5V out 5B47-J02
5B module Thermoelement J, -100°..+300°C in, 0-5V out

- **Thermocouple Type J Input:** Designed specifically for iron–constantan (Type J) thermocouples, ensuring accurate temperature measurement across a defined range. - **Input Range:** –100°C to +300°C, covering a broad span suitable for industrial and laboratory temperature monitoring. - **Output Range:** 0 to 5 V DC, providing a standardized analog signal compatible with most data acquisition and control systems. - **Linearized Output:** Internal circuitry compensates for the nonlinear characteristics of thermocouple response, delivering a linear voltage output proportional to temperature. - **High Accuracy and Stability:** Precision amplification and cold-junction compensation ensure reliable and repeatable measurements. - **Galvanic Isolation:** Input, output, and power are isolated to prevent ground loops and protect connected equipment from electrical interference. - **Compact Modular Design:** Standard 5B form factor allows easy installation into backplanes or mounting racks. - **Plug-and-Play Compatibility:** Designed for use with 5B series backplanes and carriers, simplifying integration into existing systems. - **Cold Junction Compensation (CJC):** Built-in compensation for ambient temperature variations at the thermocouple connection point. - **Rugged Industrial Construction:** Designed for harsh environments with robust electrical isolation and noise immunity.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement J,  0°..+500°C in, 0-5V out 5B47-J03
5B module Thermoelement J, 0°..+500°C in, 0-5V out

- **Thermocouple Input Type:** Type J (Iron–Constantan) - **Input Temperature Range:** 0°C to +500°C - **Output Signal:** 0 to +5 V DC, linearized with respect to temperature - **Linearization:** Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion. - **Isolation:** High galvanic isolation between input, output, and power (typically 1500 V rms or higher), protecting downstream electronics from ground loops and electrical noise. - **Accuracy:** Factory-calibrated for precise temperature measurement and output scaling. - **Low Drift:** Stable operation over time and temperature variations due to precision components and internal compensation. - **Compact Form Factor:** Standard 5B module size for easy integration into existing 5B backplanes. - **Plug-and-Play Compatibility:** Designed for use with 5B series backplanes, carriers, and mounting racks. - **Rugged Industrial Design:** Suitable for harsh environments, with robust input protection and reliable performance. - **Ease of Integration:** Directly interfaces with analog input channels of DAQ systems, controllers, and monitoring equipment. - **Cold Junction Compensation (CJC):** Built-in CJC sensor ensures accurate thermocouple measurement without external compensation. - **Signal Conditioning:** Provides amplification, filtering, and isolation in a single module.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement J, 0°..+760°C in, 0-5V out 5B47-J01
5B module Thermoelement J, 0°..+760°C in, 0-5V out

- **Thermocouple Type:** Type J (Iron–Constantan) - **Input Range:** 0°C to +760°C - **Output Range:** 0 to +5 V DC - **Linearization:** Internal cold-junction compensation and linearization for Type J thermocouple characteristics - **High Accuracy:** Factory-calibrated for precise temperature-to-voltage conversion - **Galvanic Isolation:** Provides 1500 V RMS isolation between input, output, and power to eliminate ground loops and enhance measurement integrity - **Signal Conditioning:** Includes amplification, filtering, and linearization in a single compact module - **Plug-in Module Design:** Compatible with 5B Series backplanes and mounting racks for easy installation and replacement - **Low Noise and Drift:** Designed for stable operation in industrial environments with minimal thermal drift and noise interference - **Wide Operating Temperature Range:** Suitable for use in demanding environments - **Compact Form Factor:** Optimized for high-density signal conditioning applications

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement K -100°..+1350°C in, 0-5V out 5B37-K02
5B module Thermoelement K -100°..+1350°C in, 0-5V out

- **Thermocouple Input Compatibility:** Designed for Type K thermocouples, covering a wide temperature range from –100°C to +1350°C. - **Signal Conditioning:** Converts low-level thermocouple signals into a high-level, noise-resistant 0–5 V output suitable for analog-to-digital converters (ADCs) or data acquisition systems. - **Non-linearized Output:** Provides a direct, uncorrected voltage output proportional to the thermocouple’s natural response curve, allowing external linearization or software compensation. - **High Electrical Isolation:** Incorporates 1500 V rms galvanic isolation between input, output, and power, protecting measurement systems from ground loops and high common-mode voltages. - **Compact Modular Design:** Standard 5B Series form factor for easy installation into backplanes or DIN-rail carriers. - **High Accuracy and Stability:** Precision amplification and filtering ensure low noise and minimal drift over time and temperature. - **Wide Operating Range:** Suitable for harsh industrial environments with extended temperature and humidity tolerance. - **Plug-and-Play Integration:** Compatible with 5B Series backplanes, providing standardized power and signal connections. - **Rugged Construction:** Encapsulated module design for mechanical protection and electrical shielding.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement K, 0°..+1000°C in, 0-5V out 5B47-K04
5B module Thermoelement K, 0°..+1000°C in, 0-5V out

- **Thermocouple Input Type:** Type K (Chromel–Alumel) - **Input Range:** 0°C to +1000°C - **Output Range:** 0 to +5 V DC, linearized with respect to temperature - **Linearization:** Internal cold-junction compensation and linearization circuitry for accurate temperature-to-voltage conversion - **Galvanic Isolation:** Provides 1500 V RMS isolation between input, output, and power, ensuring signal integrity and protection from ground loops - **High Accuracy:** Factory-calibrated for precise temperature measurement and voltage output scaling - **Low Drift:** Stable operation over wide temperature ranges, minimizing measurement error due to ambient variations - **Compact Form Factor:** Standard 5B module size for use in 5B backplanes and mounting racks - **Plug-and-Play Integration:** Compatible with 5B Series backplanes, data acquisition systems, and analog input modules - **High Common-Mode Rejection:** Designed to reject electrical noise and interference in industrial environments - **Cold Junction Compensation (CJC):** Built-in sensor compensates for reference junction temperature variations - **Overvoltage Protection:** Input protection against transient voltages and wiring errors - **Wide Power Supply Range:** Operates from standard 5B system power (±5 V or ±15 V depending on configuration)

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement K, 0°..+500°C in, 0-5V out 5B47-K05
5B module Thermoelement K, 0°..+500°C in, 0-5V out

- **Thermocouple Type K Input:** Designed specifically for Type K thermocouples, covering a temperature range of 0°C to +500°C. - **Linearized Output:** Provides a linear 0–5 V output corresponding directly to the input temperature range, simplifying downstream signal processing. - **High Accuracy and Stability:** Factory-calibrated for precise temperature-to-voltage conversion with minimal drift over time and temperature. - **Electrical Isolation:** Incorporates galvanic isolation between input, output, and power supply, typically rated at 1500 V rms, ensuring protection against ground loops and electrical noise. - **Compact 5B Form Factor:** Standardized plug-in module compatible with 5B backplanes and mounting systems. - **Cold Junction Compensation (CJC):** Integrated cold-junction compensation ensures accurate thermocouple measurement without external compensation circuitry. - **Low Noise and High Common-Mode Rejection:** Optimized for industrial environments with high electrical noise, providing reliable and stable readings. - **Plug-and-Play Integration:** Designed for use with 5B series backplanes, simplifying installation and replacement. - **Wide Operating Temperature Range:** Suitable for harsh industrial conditions, typically operating from -40°C to +85°C ambient. - **Rugged and Reliable:** Encapsulated design for mechanical durability and long-term reliability in demanding applications.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement R 0°..+1750°C in, 0-5V out 5B37-R05
5B module Thermoelement R 0°..+1750°C in, 0-5V out

- **Thermocouple Type R Input:** Specifically designed for platinum-rhodium (Pt13%Rh–Pt) thermocouples, covering a wide temperature range from **0°C to +1750°C**. - **Non-linearized Output:** The module provides a direct voltage output proportional to the thermocouple’s millivolt signal, scaled to 0–5 V, without internal linearization. This allows external linearization or software-based correction for high-precision applications. - **Standardized Output Signal:** Produces a **0–5 V DC output**, compatible with most analog input channels of data acquisition systems, PLCs, and control modules. - **High Electrical Isolation:** Typical 1500 V RMS isolation between input, output, and power, protecting downstream electronics from ground loops and high common-mode voltages. - **Compact Plug-in Module:** Designed for use with 5B backplanes or mounting cards, enabling modular installation and easy replacement. - **Low Noise and High Accuracy:** Engineered for stable, low-drift operation with high common-mode rejection ratio (CMRR), ensuring precise temperature measurement even in electrically noisy environments. - **Wide Operating Range:** Suitable for industrial temperature monitoring, furnace control, metallurgical processes, and laboratory instrumentation. - **Rugged Construction:** Encapsulated design for protection against mechanical stress, humidity, and contamination.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement R, 0°..+1750°C in, 0-5V out 5B47-R09
5B module Thermoelement R, 0°..+1750°C in, 0-5V out

- **Thermocouple Type R Input:** Accepts standard Type R thermocouple signals (Platinum/Platinum-Rhodium). - **Wide Temperature Range:** Measures from **0°C to +1750°C**, suitable for high-temperature industrial processes such as furnaces, kilns, and metallurgical applications. - **Linearized Output:** Provides a **0–5 V analog output** proportional to the input temperature, simplifying integration with analog input channels of data acquisition systems. - **High Accuracy and Stability:** Factory-calibrated for precise linearization and minimal drift over time and temperature. - **Galvanic Isolation:** Provides **1500 V rms isolation** between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Cold-Junction Compensation (CJC):** Built-in CJC ensures accurate thermocouple readings without external compensation circuitry. - **Plug-in Module Format:** Designed for use with 5B Series backplanes and carriers, allowing easy installation, replacement, and system expansion. - **Low Power Consumption:** Optimized for low power operation, suitable for multi-channel systems. - **Rugged Industrial Design:** Encapsulated construction for protection against vibration, humidity, and electrical interference. - **Compatibility:** Fully compatible with 5B Series backplanes, mounting racks, and data acquisition systems from Analog Devices and Measurement Computing.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement S 0°..+1750°C in, 0-5V out 5B37-S05
5B module Thermoelement S 0°..+1750°C in, 0-5V out

- **Thermocouple Type:** Type S (Platinum–Rhodium / Platinum) - **Input Range:** 0°C to +1750°C - **Output Range:** 0 to +5 V DC - **Non-linearized Output:** Provides a direct proportional voltage output without internal linearization, allowing external software or hardware compensation. - **High Accuracy and Stability:** Designed for precision temperature measurement in high-temperature industrial processes. - **Galvanic Isolation:** Typical 1500 V RMS isolation between input, output, and power, ensuring signal integrity and protection against ground loops. - **Compact 5B Series Form Factor:** Standardized plug-in module compatible with 5B backplanes and carriers. - **Cold Junction Compensation (CJC):** Typically integrated within the 5B37 module family to maintain measurement accuracy across ambient temperature variations. - **Low Noise and High Common-Mode Rejection:** Ensures reliable operation in electrically noisy industrial environments. - **Wide Operating Temperature Range:** Suitable for harsh industrial conditions. - **Plug-and-Play Integration:** Compatible with 5B Series backplanes, data acquisition systems, and PLC I/O modules.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement S, 0°..+1000°C in, 0-5V out 5B47-S10
5B module Thermoelement S, 0°..+1000°C in, 0-5V out

- **Thermocouple Input Type:** Type S (Platinum-Rhodium / Platinum) - **Input Range:** 0°C to +1750°C (linearized measurement range) - **Nominal Operating Range:** 0°C to +1000°C (as specified for the S10 variant) - **Output Range:** 0 to +5 V DC (standardized analog output) - **Linearization:** Internal linearization for Type S thermocouple response curve - **Cold Junction Compensation (CJC):** Built-in, ensuring accurate temperature readings independent of ambient conditions - **High Accuracy:** Factory-calibrated for precise thermocouple signal conditioning - **Galvanic Isolation:** Input-to-output and channel-to-channel isolation to prevent ground loops and electrical interference - **Compact Form Factor:** Standard 5B module size for use with 5B backplanes and mounting racks - **Plug-and-Play Integration:** Compatible with 5B Series backplanes, data acquisition systems, and signal conditioning racks - **High Common-Mode Rejection:** Ensures stable operation in noisy industrial environments - **Rugged Design:** Designed for industrial temperature ranges and long-term reliability - **Low Power Consumption:** Optimized for multi-channel systems and embedded DAQ applications

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement S, 0°..+1800°C in, 0-5V out 5B47-S11
5B module Thermoelement S, 0°..+1800°C in, 0-5V out

- **Thermocouple Input Type:** Type S (Platinum-Rhodium / Platinum) - **Input Range:** 0°C to +1800°C - **Output Range:** 0 V to +5 V (linearized) - **Linearization:** Internal cold-junction compensation and linearization for Type S thermocouple characteristics - **High Accuracy:** Factory-calibrated for precise temperature-to-voltage conversion - **Electrical Isolation:** 1500 V RMS isolation between input, output, and power to protect against ground loops and electrical noise - **Compact Form Factor:** Standard 5B module size for plug-in installation into 5B backplanes or carriers - **Low Drift and High Stability:** Designed for long-term accuracy and minimal temperature drift - **Plug-and-Play Compatibility:** Fully compatible with 5B Series backplanes, data acquisition systems, and signal conditioning racks - **Rugged Industrial Design:** Suitable for harsh environments, with robust construction and reliable performance - **Ease of Integration:** Standardized pinout and mechanical interface for quick installation and replacement Unique selling points include its **factory-calibrated linearization for Type S thermocouples**, **high isolation voltage**, and **standardized 0–5 V output**, making it ideal for integration with analog input channels of PLCs, DAQs, and control systems.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement T -100°..+400°C in, 0-5V out 5B37-T03
5B module Thermoelement T -100°..+400°C in, 0-5V out

- **Thermocouple Type T Input:** Designed specifically for Type T (copper-constantan) thermocouples, ensuring accurate measurement of low-temperature ranges. - **Input Range:** –100°C to +400°C, suitable for laboratory, industrial, and process monitoring applications. - **Output Range:** 0–5 V DC, compatible with most analog input channels on data acquisition systems and controllers. - **Non-linearized Output:** Provides a direct proportional voltage output without internal linearization, allowing external systems or software to perform custom linearization or compensation. - **High Common-Mode Isolation:** Typical 1500 V RMS isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Compact 5B Series Form Factor:** Standardized plug-in module design for use with 5B backplanes and carriers. - **Cold Junction Compensation (CJC):** Typically integrated within the 5B37 module family to ensure accurate thermocouple readings by compensating for reference junction temperature variations. - **High Accuracy and Stability:** Precision amplification and filtering circuitry minimize drift and noise, ensuring reliable long-term operation. - **Wide Operating Temperature Range:** Designed for industrial environments, typically –40°C to +85°C operating range. - **Plug-and-Play Compatibility:** Fully compatible with 5B backplanes, mounting racks, and data acquisition systems supporting the 5B interface standard.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement T,  0°..+200°C in, 0-5V out 5B47-T07
5B module Thermoelement T, 0°..+200°C in, 0-5V out

- **Thermocouple Input (Type T):** Accepts direct connection from Type T thermocouples (Copper-Constantan). - **Input Range:** 0°C to +200°C, optimized for low-temperature measurement applications. - **Output Signal:** Linearized 0–5 V DC analog output, directly proportional to the measured temperature. - **Linearization:** Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion. - **Galvanic Isolation:** Provides high-level isolation between input, output, and power supply, typically rated at 1500 V rms or higher, protecting downstream equipment and reducing ground loop interference. - **High Accuracy and Stability:** Designed for precision measurement with low drift and high common-mode rejection ratio (CMRR). - **Compact 5B Form Factor:** Standardized plug-in module compatible with 5B backplanes and carriers. - **Ease of Integration:** Standard 0–5 V output allows direct interface with analog input channels of data acquisition systems, PLCs, and control systems. - **Rugged Industrial Design:** Suitable for harsh environments, with robust construction and reliable performance over extended temperature ranges. - **Low Power Consumption:** Optimized for multi-channel systems with minimal heat generation. - **Plug-and-Play Compatibility:** Works with standard 5B backplanes, simplifying installation and replacement.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module Thermoelement T, -100°..+400°C in, 0-5V out 5B47-T06
5B module Thermoelement T, -100°..+400°C in, 0-5V out

- **Thermocouple Type T Input:** Designed for copper-constantan thermocouples, offering high accuracy and stability over the specified temperature range. - **Input Range:** -100°C to +400°C, covering a broad span suitable for low- to medium-temperature industrial and laboratory processes. - **Output Signal:** 0–5 V DC linearized output, compatible with most analog input systems. - **Linearization:** Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion across the entire range. - **Galvanic Isolation:** Provides 1500 V RMS isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **High Accuracy and Stability:** Typical accuracy better than ±0.1% of full scale, with low drift over time and temperature. - **Compact Modular Design:** Standard 5B form factor for use in backplanes or DIN-rail carriers, enabling flexible system configuration. - **Plug-and-Play Compatibility:** Fully compatible with 5B Series backplanes and data acquisition systems. - **Low Power Consumption:** Designed for efficient operation in multi-channel systems. - **Rugged Industrial Construction:** Encapsulated module for protection against vibration, humidity, and electrical interference.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module wide band, ±10mV in, ±5V out 5B40
5B module wide band, ±10mV in, ±5V out

- **Wide Bandwidth Design:** Optimized for high-frequency signal conditioning, enabling accurate transmission of dynamic or rapidly changing analog signals. - **Input Range:** ±10 mV differential input range, ideal for low-level sensor or transducer signals. - **Output Range:** ±5 V analog output, compatible with standard data acquisition (DAQ) systems and analog input modules. - **High Accuracy and Linearity:** Provides precise signal amplification with minimal distortion or drift. - **Galvanic Isolation:** Input-to-output and power isolation to eliminate ground loops and protect downstream equipment. - **Compact Modular Form Factor:** Standard 5B Series plug-in module design for easy installation and replacement. - **Low Noise Performance:** Engineered for low input noise and high signal-to-noise ratio (SNR). - **Rugged Industrial Design:** Operates reliably in harsh environments with wide temperature tolerance and robust mechanical construction. - **Compatibility:** Fully compatible with 5B Series backplanes, carriers, and mounting systems. - **Ease of Integration:** Standardized pinout and mechanical interface for seamless integration into existing 5B-based systems.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module wide band,, ±1V in, ±5V out 5B41
5B module wide band,, ±1V in, ±5V out

- **Wide Bandwidth Performance:** Designed for high-frequency analog signals, the 5B41 offers wide-band operation suitable for dynamic signal measurement and conditioning. - **Input/Output Range:** Accepts a **±1 V input** and provides a **±5 V output**, enabling signal amplification by a factor of 5. - **High Linearity and Accuracy:** Ensures precise signal reproduction with minimal distortion and low nonlinearity across the full input range. - **Electrical Isolation:** Provides **1500 V rms isolation** between input, output, and power, protecting downstream equipment and reducing ground loop interference. - **Compact Plug-In Module:** Fits into standard 5B Series backplanes and carriers, allowing modular configuration and easy replacement. - **High Common-Mode Rejection:** Excellent CMRR performance ensures accurate measurement even in noisy industrial environments. - **Low Noise Design:** Optimized internal circuitry minimizes noise contribution, preserving signal integrity. - **Wide Operating Temperature Range:** Suitable for harsh environments, typically operating from **–40°C to +85°C**. - **Compatibility:** Fully compatible with 5B Series backplanes, mounting racks, and data acquisition systems. - **Factory Calibrated:** Each module is factory calibrated for its specified input/output range, ensuring out-of-the-box accuracy.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module ±100mV in, 0-5V out, 4Hz 5B30-06
5B module ±100mV in, 0-5V out, 4Hz

- **Input Range:** ±100 millivolts (mV) differential input - **Output Range:** 0 to +5 volts (V) single-ended output - **Bandwidth:** 4 Hz nominal frequency response, optimized for low-frequency or slowly varying signals - **High Accuracy:** Designed for precise low-level signal amplification with minimal offset and drift - **Electrical Isolation:** Provides galvanic isolation between input, output, and power, typically rated at 1500 V rms or higher, protecting data acquisition equipment from ground loops and transients - **Low Noise Performance:** Internal filtering and shielding minimize noise pickup and interference - **Compact Modular Design:** Standard 5B form factor for plug-in installation into 5B backplanes or carriers - **Signal Conditioning Flexibility:** Part of a modular system supporting a wide range of input types (voltage, current, thermocouple, RTD, strain gauge, etc.) - **Factory Calibrated:** Each module is pre-calibrated for its specified input/output range, ensuring consistent performance without field adjustment - **Rugged Industrial Construction:** Designed for reliable operation in demanding environments, with wide operating temperature range and robust mechanical design - **Ease of Integration:** Compatible with standard 5B backplanes, data acquisition cards, and I/O subsystems

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module ±100mV in, ±5V out, 4Hz 5B30-03
5B module ±100mV in, ±5V out, 4Hz

- **Input Range:** ±100 mV DC nominal input range, suitable for low-level sensor or transducer signals. - **Output Range:** ±5 V DC, compatible with standard analog input channels of data acquisition systems. - **Bandwidth:** 4 Hz, optimized for low-frequency or slowly varying signals such as temperature, strain, or pressure measurements. - **High Accuracy:** Provides precise signal scaling and conditioning with minimal offset and gain error. - **Electrical Isolation:** Offers 1500 V (typical) galvanic isolation between input, output, and power, protecting data acquisition systems from ground loops and high common-mode voltages. - **Low Noise Design:** Incorporates filtering and shielding to minimize noise pickup and interference. - **Compact Form Factor:** Standard 5B module size for easy integration into 5B backplanes and mounting racks. - **Plug-and-Play Compatibility:** Fully compatible with 5B Series backplanes, carriers, and data acquisition interfaces. - **Rugged Construction:** Designed for industrial environments with wide operating temperature range and high reliability. - **Factory Calibrated:** Each module is pre-calibrated for its specified input/output range, ensuring consistent performance.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen
5B module ±10mV in, 0-5V out, 4Hz 5B30-04
5B module ±10mV in, 0-5V out, 4Hz

- **Input Range:** ±10 millivolts (mV) - **Output Range:** 0 to +5 volts (V) - **Bandwidth:** 4 Hz (nominal) - **Signal Conditioning Type:** Linear voltage input to voltage output conversion - **Isolation:** Typically 1500 V rms input-to-output and power isolation (standard for 5B modules) - **Accuracy:** High precision and low drift for stable long-term operation - **Noise Rejection:** Excellent common-mode rejection ratio (CMRR) for low-level signal integrity - **Compact Form Factor:** Standard 5B module size for plug-in installation into 5B backplanes or carriers - **Ease of Integration:** Compatible with a wide range of data acquisition systems, PLCs, and analog input cards - **Low Power Consumption:** Designed for efficient operation in multi-channel systems - **Rugged Design:** Industrial-grade construction for reliable performance in harsh environments The 5B30-04’s unique selling point lies in its ability to accurately amplify and condition extremely low-level voltage signals (±10 mV) into a standardized 0–5 V output, suitable for direct interface with analog-to-digital converters (ADCs) or control systems. Its 4 Hz bandwidth ensures stable, noise-free measurements for slowly varying signals.

Hersteller: Keine Kategorie

Kategorie: Signalkonditionierung 5B Module

Angebot anfragen