DAQe-2016

PCIe AD 800kS/s simult. 4chan 16bit
  • Hersteller Adlink Technology Inc.
  • Kategorie: A/D Intelligent PCIe
  • The ADLINK DAQe‑2016 is a high‑performance, four‑channel, 16‑bit, simultaneous‑sampling multifunction data acquisition (DAQ) card designed for PCI Express® systems. It belongs to the DAQe‑2000 family, which extends the proven DAQ‑2000 PCI series to the PCIe bus architecture. The DAQe‑2016 provides 800 kS/s per channel simultaneous analog input sampling, dual 12‑bit analog outputs, 24‑channel digital I/O, and dual 16‑bit general‑purpose timer/counters.
- Simultaneous Sampling:
Four differential analog input channels sampled simultaneously at up to 800 kS/s per channel, ensuring phase‑accurate acquisition across multiple signals.

- High Resolution:
16‑bit analog‑to‑digital conversion with no missing codes for precise signal representation.

- Flexible Input Ranges:
Programmable bipolar ranges of ±10 V, ±5 V, ±2.5 V, ±1.25 V and unipolar ranges of 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V.

- Dual Analog Outputs:
Two 12‑bit voltage outputs (0–10 V, ±10 V, or external reference) with 1 MS/s update rate and waveform generation capability.

- Digital I/O:
24 programmable TTL/CMOS‑compatible digital I/O lines (8255 PIO compatible).

- Timer/Counter:
Two 16‑bit up/down general‑purpose counters with 40 MHz internal or up to 10 MHz external clock.

- Triggering:
Supports software, external analog, external digital, and SSI (System Synchronization Interface) triggers with multiple trigger modes: pre‑trigger, post‑trigger, middle‑trigger, delay‑trigger, and repeated trigger.

- Auto‑Calibration:
On‑board precision 5.000 V reference with ±2 ppm/°C drift and 6 ppm/1000 h stability; automatic gain and offset calibration eliminates manual trimpot adjustment.

- High Noise Immunity:
Piggy‑back analog/digital board design and dedicated DC/DC regulation minimize digital noise coupling.

- Bus‑Mastering DMA with Scatter‑Gather:
High‑speed data transfer directly to system memory without CPU overhead, supporting fragmented memory blocks.

- Multiple‑Card Synchronization:
SSI bus allows synchronization of up to four cards for expanded channel counts and coherent sampling.

- Software Support:
Compatible with ADLINK D2K‑DASK (Windows), D2K‑DASK/X (Linux), LabVIEW® (D2K‑LVIEW), and ActiveX (D2K‑OCX) drivers.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8473 3020 000

Comprehensive Product Summary: ADLINK DAQe‑2016 PCI Express® Data Acquisition Card
*(Approx. 12,000 characters / ~3,000 tokens)*




### 1. Product Overview

Product Name: DAQe‑2016
Model: DAQe‑2016
Series: DAQe‑2000 Series (PCI Express® Simultaneous‑Sampling Multi‑Function DAQ Cards)
Article Number: DAQe‑2016
Manufacturer: ADLINK Technology Inc.

The ADLINK DAQe‑2016 is a high‑performance, four‑channel, 16‑bit, simultaneous‑sampling multifunction data acquisition (DAQ) card designed for PCI Express® systems. It belongs to the DAQe‑2000 family, which extends the proven DAQ‑2000 PCI series to the PCIe bus architecture. The DAQe‑2016 provides 800 kS/s per channel simultaneous analog input sampling, dual 12‑bit analog outputs, 24‑channel digital I/O, and dual 16‑bit general‑purpose timer/counters. It integrates advanced triggering, auto‑calibration, and synchronization capabilities, making it ideal for high‑speed measurement, control, and test applications.




### 2. Key Features

- Simultaneous Sampling:
Four differential analog input channels sampled simultaneously at up to 800 kS/s per channel, ensuring phase‑accurate acquisition across multiple signals.

- High Resolution:
16‑bit analog‑to‑digital conversion with no missing codes for precise signal representation.

- Flexible Input Ranges:
Programmable bipolar ranges of ±10 V, ±5 V, ±2.5 V, ±1.25 V and unipolar ranges of 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V.

- Dual Analog Outputs:
Two 12‑bit voltage outputs (0–10 V, ±10 V, or external reference) with 1 MS/s update rate and waveform generation capability.

- Digital I/O:
24 programmable TTL/CMOS‑compatible digital I/O lines (8255 PIO compatible).

- Timer/Counter:
Two 16‑bit up/down general‑purpose counters with 40 MHz internal or up to 10 MHz external clock.

- Triggering:
Supports software, external analog, external digital, and SSI (System Synchronization Interface) triggers with multiple trigger modes: pre‑trigger, post‑trigger, middle‑trigger, delay‑trigger, and repeated trigger.

- Auto‑Calibration:
On‑board precision 5.000 V reference with ±2 ppm/°C drift and 6 ppm/1000 h stability; automatic gain and offset calibration eliminates manual trimpot adjustment.

- High Noise Immunity:
Piggy‑back analog/digital board design and dedicated DC/DC regulation minimize digital noise coupling.

- Bus‑Mastering DMA with Scatter‑Gather:
High‑speed data transfer directly to system memory without CPU overhead, supporting fragmented memory blocks.

- Multiple‑Card Synchronization:
SSI bus allows synchronization of up to four cards for expanded channel counts and coherent sampling.

- Software Support:
Compatible with ADLINK D2K‑DASK (Windows), D2K‑DASK/X (Linux), LabVIEW® (D2K‑LVIEW), and ActiveX (D2K‑OCX) drivers.




### 3. Technical Specifications

Analog Input (AI):
- Channels: 4 differential, simultaneous sampling
- Resolution: 16 bits, no missing codes
- Max Sampling Rate: 800 kS/s per channel
- Input Ranges:
- Bipolar: ±10 V, ±5 V, ±2.5 V, ±1.25 V
- Unipolar: 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V
- Programmable Gain: 1, 2, 4, 8
- Input Coupling: DC
- Input Impedance: 1 GΩ // 100 pF
- Overvoltage Protection: ±35 V (power on), ±15 V (power off)
- CMRR (Gain = 1): 85 dB typical
- Bandwidth (–3 dB, Gain = 1): 600 kHz typical
- Offset Error (after calibration): ±1 mV
- Gain Error (after calibration): ±0.01 % of FSR
- FIFO Buffer: 512 samples
- Data Transfer: Programmed I/O or scatter‑gather DMA
- Trigger Sources: Software, external analog/digital, SSI bus
- Trigger Modes: Pre‑, Post‑, Middle‑, Delay‑, and Repeated Trigger

Analog Output (AO):
- Channels: 2 voltage outputs
- Resolution: 12 bits
- Output Ranges: 0–10 V, ±10 V, 0–AOEXTREF, ±AOEXTREF
- Max Update Rate: 1 MS/s
- Slew Rate: 20 V/µs
- Settling Time: 3 µs to ±0.5 LSB
- Offset Error: ±1 mV
- Gain Error: ±0.02 % of max output
- Drive Capability: ±5 mA, load ≤ 1500 pF
- FIFO Buffer: 2 k samples
- Trigger Sources: Software, external analog/digital, SSI bus
- Trigger Modes: Post‑, Delay‑, and Repeated Trigger
- Data Transfer: Programmed I/O or scatter‑gather DMA

Digital I/O:
- Channels: 24 programmable I/O (8255 compatible)
- Logic Levels: TTL/CMOS (5 V)
- Data Transfer: Programmed I/O

Timer/Counter:
- Channels: 2 independent up/down counters
- Resolution: 16 bits
- Compatibility: TTL
- Base Clock: 40 MHz internal or up to 10 MHz external

Auto‑Calibration Reference:
- Reference Voltage: 5.000 V
- Temperature Drift: ±2 ppm/°C
- Long‑Term Stability: 6 ppm/1000 h

General:
- Dimensions: 168 mm × 107 mm (excluding connectors)
- Connector: 68‑pin VHDCI female
- Operating Temperature: 0 °C – 55 °C
- Storage Temperature: –20 °C – 70 °C
- Humidity: 5 % – 95 %, non‑condensing
- Power Requirements (typical): +3.3 V @ 0.569 A, +12 V @ 1.097 A




### 4. Functionality

The DAQe‑2016 performs high‑speed, simultaneous analog data acquisition and generation through its PCI Express® interface. Each of the four differential analog input channels is digitized by a dedicated 16‑bit ADC, ensuring true simultaneous sampling without channel skew. The card’s programmable gain amplifier allows per‑channel range configuration for optimal resolution.

Analog outputs are generated by two 12‑bit DACs capable of waveform generation at up to 1 MS/s. Both analog input and output subsystems can operate concurrently at full speed, enabling closed‑loop control or stimulus/response testing.

Use Cases and Applications:
- Transient signal capture and waveform analysis
- Automotive and aerospace sensor testing
- Automated test equipment (ATE)
- Process control and industrial monitoring
- Biomedical and biotech instrumentation
- Laboratory automation and research data logging

Compatibility:
- PCI Express® x1 interface, compatible with x4/x8/x16 slots
- Supports Windows NT/2000/XP/7/10 and Linux (kernel 2.4.x – 2.6.x)
- Integrates with LabVIEW®, DASYLab®, HP VEE, and custom C/C++/VB applications




### 5. Components & Accessories

Included:
- DAQe‑2016 PCIe DAQ card
- ADLINK All‑in‑One Software CD (drivers, libraries, manuals)
- Software Installation Guide

Optional Accessories:
- DIN‑68S‑01: 68‑pin SCSI‑II termination board with DIN‑rail mounting
- ACL‑10568‑1: 68‑pin VHDCI cable (1 m)
- ACL‑SSI‑2/3/4: SSI bus cables for synchronization of 2, 3, or 4 devices

Connectors:
- One 68‑pin VHDCI female connector for analog, digital, and timing I/O
- One 20‑pin SSI connector for synchronization signals




### 6. Installation & Setup

System Requirements:
- PCI Express® slot (x1 or higher)
- +3.3 V and +12 V power rails
- Supported OS with ADLINK driver package installed

Installation Steps:
1. Power off the host PC and discharge static electricity.
2. Insert the DAQe‑2016 into an available PCIe slot.
3. Secure the bracket and reconnect power.
4. Install ADLINK D2K‑DASK or D2K‑DASK/X drivers from the provided CD.
5. Verify installation using ADLINK’s diagnostic utilities.

Mounting Options:
- Standard PCIe bracket for desktop or industrial chassis
- Optional DIN‑rail termination board for field wiring

Configuration:
- Fully jumper‑less; all parameters (gain, range, trigger, clock source) are software‑configurable.
- Plug‑and‑play PCIe enumeration automatically assigns resources.




### 7. Performance & Capabilities

Analog Input Performance:
- 16‑bit resolution ensures 1 part in 65,536 precision.
- 800 kS/s simultaneous sampling across four channels.
- Typical –3 dB bandwidth of 600 kHz supports high‑frequency transient capture.
- Input noise < 2 LSBrms typical.
- Excellent linearity and low drift due to auto‑calibration.

Analog Output Performance:
- 12‑bit resolution with 1 MS/s update rate.
- 20 V/µs slew rate and 3 µs settling time to ±0.5 LSB.
- Supports finite, infinite, and retriggerable waveform generation.

Digital I/O and Timing:
- 24 lines configurable as input or output for control and monitoring.
- Two 16‑bit counters support event counting, frequency measurement, and pulse generation up to 10 MHz.

DMA Throughput:
- Scatter‑gather bus‑mastering DMA transfers data directly to system memory, sustaining high throughput without CPU load.
- Supports fragmented memory blocks for large continuous acquisitions.

Limitations:
- Maximum analog input rate limited to 800 kS/s per channel.
- Analog output limited to 1 MS/s shared across two channels.
- No galvanic isolation between analog and digital sections (requires proper grounding).




### 8. Standards & Compliance

- Bus Interface: PCI Express® x1 compliant
- Digital Logic Levels: TTL/CMOS compatible
- Environmental:
- Operating: 0 – 55 °C
- Storage: –20 – 70 °C
- Humidity: 5 – 95 % RH, non‑condensing
- Safety & EMC: Designed to meet CE and FCC Class A industrial standards
- Calibration Reference: 5 V precision source, ±2 ppm/°C drift
- Software Standards:
- D2K‑DASK API for Windows
- D2K‑DASK/X for Linux
- LabVIEW® VI library (D2K‑LVIEW)
- ActiveX/OCX components for Visual Basic and C++




### 9. Additional Information

Warranty:
- Two‑year limited warranty (one year in China) from date of shipment.
- Covers manufacturing defects; excludes damage from misuse, improper installation, or environmental factors.

Support & Maintenance:
- Free driver and software updates via ADLINK website.
- Technical assistance available through service@adlinktech.com.
- RMA service supported via online request form.

Calibration & Maintenance:
- Factory‑calibrated prior to shipment.
- Auto‑calibration can be initiated via software; no external reference required.
- Recommended warm‑up time: 15 minutes before calibration.
- Calibration constants stored in EEPROM (factory and three user banks).

Software Ecosystem:
- Windows: D2K‑DASK library (DLL), D2K‑OCX ActiveX, D2K‑LVIEW LabVIEW® driver.
- Linux: D2K‑DASK/X shared library (C/C++).
- Third‑Party Integration: DASYLab®, HP VEE, and DAQBench ActiveX controls.

Documentation & Resources:
- User’s Manual (Rev. 2.00)
- Software Installation Guide
- Example programs and function reference manuals included on CD




### Summary

The ADLINK DAQe‑2016 is a robust, high‑precision PCI Express® data acquisition card engineered for demanding measurement and control applications. With four 16‑bit simultaneous‑sampling analog inputs at 800 kS/s, dual 12‑bit analog outputs, 24 digital I/O lines, and dual 16‑bit counters, it delivers a complete multifunction DAQ solution in a compact PCIe form factor. Its auto‑calibration, advanced triggering, and synchronization features ensure accuracy and flexibility, while bus‑mastering DMA and scatter‑gather capabilities provide efficient high‑speed data throughput. Supported by comprehensive software drivers for Windows, Linux, and major test environments, the DAQe‑2016 offers a reliable, scalable platform for industrial automation, scientific research, and high‑speed data logging.