- 32-Channel Scan/Multiplexer Configuration: Provides 32 independent Form A relay channels for flexible signal routing and multiplexing operations.
- Form A Relay Type: Utilizes single-pole, single-throw (SPST) normally open relays, ensuring reliable mechanical switching and long operational life.
- PXI / CompactPCI 3U Form Factor: Fully compliant with PXI and CompactPCI 3U mechanical and electrical specifications, enabling integration into standard PXI chassis.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, supporting a wide range of analog and digital signal types without significant signal degradation.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 hot-swap specifications, allowing insertion and removal without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying setup and reducing integration time.
- High Power Handling: Rated for 30 W, 125 VAC, or 30 VDC at 0.5 A, suitable for moderate power signal switching applications.
- Compact and Durable Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring robust connectivity and mechanical stability.
- PXI System Compatibility: Designed for seamless operation with ADLINK and third-party PXI controllers, chassis, and software environments.
- Form A Relay Type: Utilizes single-pole, single-throw (SPST) normally open relays, ensuring reliable mechanical switching and long operational life.
- PXI / CompactPCI 3U Form Factor: Fully compliant with PXI and CompactPCI 3U mechanical and electrical specifications, enabling integration into standard PXI chassis.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, supporting a wide range of analog and digital signal types without significant signal degradation.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 hot-swap specifications, allowing insertion and removal without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying setup and reducing integration time.
- High Power Handling: Rated for 30 W, 125 VAC, or 30 VDC at 0.5 A, suitable for moderate power signal switching applications.
- Compact and Durable Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring robust connectivity and mechanical stability.
- PXI System Compatibility: Designed for seamless operation with ADLINK and third-party PXI controllers, chassis, and software environments.
1. Product Overview
Name: PXI-7614
Model: PXI-7614
Series: PXI / CompactPCI (cPCI) Switching and Multiplexing Modules
Article Number: PXI-7614
Manufacturer: ADLINK Technology Inc.
The ADLINK PXI-7614 is a high-performance PXI/cPCI 3U 32-channel Scan/Multiplexer (Scan/MUX) Form A Relay Card designed for automated test and measurement systems requiring flexible signal routing, high channel density, and reliable switching performance. It integrates seamlessly into PXI and CompactPCI platforms, providing a robust and scalable solution for signal switching, scanning, and multiplexing applications in laboratory, production, and field environments.
2. Key Features
- 32-Channel Scan/Multiplexer Configuration: Provides 32 independent Form A relay channels for flexible signal routing and multiplexing operations.
- Form A Relay Type: Utilizes single-pole, single-throw (SPST) normally open relays, ensuring reliable mechanical switching and long operational life.
- PXI / CompactPCI 3U Form Factor: Fully compliant with PXI and CompactPCI 3U mechanical and electrical specifications, enabling integration into standard PXI chassis.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, supporting a wide range of analog and digital signal types without significant signal degradation.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 hot-swap specifications, allowing insertion and removal without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying setup and reducing integration time.
- High Power Handling: Rated for 30 W, 125 VAC, or 30 VDC at 0.5 A, suitable for moderate power signal switching applications.
- Compact and Durable Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring robust connectivity and mechanical stability.
- PXI System Compatibility: Designed for seamless operation with ADLINK and third-party PXI controllers, chassis, and software environments.
3. Technical Specifications
- Bus Interface: PXI / CompactPCI 3U
- Card Type: 32-channel Scan/Multiplexer (Scan/MUX)
- Relay Type: Form A (SPST, Normally Open)
- Number of Channels: 32
- Bandwidth: 10 MHz (-3 dB point)
- Maximum Switching Power: 30 W
- Maximum Switching Voltage: 125 VAC / 30 VDC
- Maximum Switching Current: 0.5 A
- Connector Type: 160-pin, 2 mm pitch
- Board Dimensions: 100 mm (height) × 160 mm (depth)
- Form Factor: 3U PXI / CompactPCI
- Compliance: PICMG 2.1 R1.0 (Hot Swap)
- Operating Mode: Plug and Play, software-configurable
- Manufacturer: ADLINK Technology Inc.
4. Functionality
The PXI-7614 functions as a 32-channel scanning and multiplexing relay card within a PXI or CompactPCI system. Each of the 32 channels can be individually controlled to connect or disconnect signals, enabling flexible routing of analog or digital signals between instruments, devices under test (DUTs), and measurement equipment.
Operational Principle:
- Each Form A relay acts as a single-pole, single-throw (SPST) switch.
- The relays can be controlled programmatically through PXI software interfaces, allowing dynamic configuration of signal paths.
- The card supports scanning operations, where channels are sequentially connected to a common bus for measurement or signal acquisition.
- Multiplexing functionality allows multiple input signals to be routed to a single output channel, or vice versa, depending on system configuration.
Use Cases and Applications:
- Automated Test Equipment (ATE) systems for electronic component and subsystem testing.
- Signal routing and switching in data acquisition systems.
- Functional testing of analog and digital circuits.
- Sensor and transducer signal multiplexing.
- Laboratory instrumentation requiring flexible signal interconnection.
- Production line testing and quality assurance setups.
Compatibility:
- Fully compatible with PXI and CompactPCI 3U chassis and controllers.
- Operates with ADLINK’s PXI controllers and software tools.
- Supports integration with third-party PXI software environments such as NI LabVIEW™, NI TestStand™, and other PXI-compliant frameworks.
5. Components & Accessories
Included Items:
- PXI-7614 32-Channel Scan/MUX Form A Relay Card
- User documentation and quick start guide
- Software drivers and configuration utilities (available via ADLINK support portal)
Optional Accessories:
- PXI-compatible chassis (3U)
- PXI controller (embedded or remote)
- Signal interface cables and terminal blocks compatible with the 160-pin 2 mm connector
- Relay replacement kits (for maintenance)
- Mounting hardware and alignment guides for PXI chassis installation
Connectors:
- Primary Connector: 160-pin, 2 mm pitch PXI/cPCI backplane connector for data, control, and power interface.
- Signal Interface: Routed through the PXI backplane or via front-panel connection (depending on system configuration).
6. Installation & Setup
Requirements:
- PXI or CompactPCI 3U chassis with available slot
- Compatible PXI controller or host interface
- Supported operating system and driver software
Mounting Options:
- Standard PXI 3U slot installation using the 160-pin backplane connector.
- Hot-swappable insertion and removal per PICMG 2.1 R1.0 compliance.
Configuration Steps:
1. Power down the PXI chassis (if not using hot-swap).
2. Insert the PXI-7614 card into an available 3U slot, ensuring proper alignment with the backplane connector.
3. Secure the module using front-panel screws or latches.
4. Power on the chassis; the PXI system will automatically detect the module (Plug and Play).
5. Install ADLINK-provided drivers and software utilities.
6. Configure channel assignments and relay control parameters through the software interface.
Software Integration:
- Supports standard PXI software frameworks.
- Compatible with ADLINK’s driver libraries and APIs for C/C++, LabVIEW™, and other programming environments.
- Provides diagnostic and self-test functions for verifying relay operation and connectivity.
7. Performance & Capabilities
Switching Performance:
- Bandwidth: 10 MHz (-3 dB), suitable for low- to mid-frequency analog signals.
- Switching Power: Up to 30 W, enabling moderate power signal routing.
- Voltage and Current Ratings: 125 VAC or 30 VDC at 0.5 A maximum per channel.
- Relay Type: Mechanical Form A relays ensure low contact resistance and high isolation.
Speed and Efficiency:
- Relay switching time typically in the millisecond range (dependent on relay characteristics).
- Efficient signal routing with minimal crosstalk and insertion loss within the specified bandwidth.
- Optimized for high reliability and long operational life in continuous test environments.
Limitations:
- Not intended for high-frequency RF switching beyond 10 MHz.
- Maximum current limited to 0.5 A per channel; higher loads require external switching solutions.
- Mechanical relays subject to wear over extended use; periodic maintenance recommended.
Reliability:
- Designed for industrial-grade operation with robust mechanical construction.
- High-quality relays rated for thousands of switching cycles.
- Stable performance across a wide range of environmental conditions (within PXI chassis specifications).
8. Standards & Compliance
- PXI Compliance: Fully compliant with PXI specifications for mechanical, electrical, and software interfaces.
- CompactPCI Compliance: Meets CompactPCI 3U form factor and electrical standards.
- Hot Swap Compliance: Conforms to PICMG 2.1 R1.0 for hot-swappable modules.
- Safety and Electrical Ratings:
- Maximum 125 VAC / 30 VDC switching voltage
- Maximum 0.5 A switching current
- Maximum 30 W switching power
- Environmental and Quality Standards:
- Manufactured under ISO 9001 quality management systems.
- RoHS-compliant materials and lead-free soldering processes.
- Regulatory Compliance:
- CE marking for electromagnetic compatibility and safety.
- FCC compliance for emissions and interference control (typical for PXI modules).
9. Additional Information
Warranty:
- Standard manufacturer’s warranty (typically one year, extendable depending on region and distributor).
- Covers defects in materials and workmanship under normal operating conditions.
Support:
- Technical support available through ADLINK’s global service network.
- Online resources include driver downloads, manuals, and application notes.
- Firmware and software updates provided via ADLINK’s support portal.
Maintenance:
- Periodic inspection of relay operation recommended for high-duty-cycle applications.
- Replacement relays or modules available through authorized service centers.
- Keep connectors clean and free from dust to maintain signal integrity.
Updates and Lifecycle:
- Supported within ADLINK’s PXI product roadmap for long-term availability.
- Compatible with future PXI software and hardware revisions.
- Firmware and driver updates ensure continued compatibility with evolving test systems.
Summary
The ADLINK PXI-7614 is a PXI/cPCI 3U 32-channel Scan/Multiplexer Form A Relay Card engineered for precision signal switching and multiplexing in automated test and measurement environments. With its 10 MHz bandwidth, 30 W power rating, and hot-swappable PXI interface, it delivers a balance of performance, reliability, and flexibility. The module’s Form A relays provide dependable mechanical switching, while Plug and Play functionality simplifies integration into PXI systems.
Designed to meet PICMG 2.1 R1.0 and PXI standards, the PXI-7614 ensures compatibility with a wide range of PXI chassis and controllers. Its 160-pin 2 mm connector and 100 × 160 mm 3U form factor make it ideal for dense, modular test setups. Whether used for signal scanning, routing, or multiplexing, the PXI-7614 offers a robust, standards-compliant solution for engineers and system integrators seeking reliable switching performance in compact, scalable PXI platforms.
Name: PXI-7614
Model: PXI-7614
Series: PXI / CompactPCI (cPCI) Switching and Multiplexing Modules
Article Number: PXI-7614
Manufacturer: ADLINK Technology Inc.
The ADLINK PXI-7614 is a high-performance PXI/cPCI 3U 32-channel Scan/Multiplexer (Scan/MUX) Form A Relay Card designed for automated test and measurement systems requiring flexible signal routing, high channel density, and reliable switching performance. It integrates seamlessly into PXI and CompactPCI platforms, providing a robust and scalable solution for signal switching, scanning, and multiplexing applications in laboratory, production, and field environments.
2. Key Features
- 32-Channel Scan/Multiplexer Configuration: Provides 32 independent Form A relay channels for flexible signal routing and multiplexing operations.
- Form A Relay Type: Utilizes single-pole, single-throw (SPST) normally open relays, ensuring reliable mechanical switching and long operational life.
- PXI / CompactPCI 3U Form Factor: Fully compliant with PXI and CompactPCI 3U mechanical and electrical specifications, enabling integration into standard PXI chassis.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, supporting a wide range of analog and digital signal types without significant signal degradation.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 hot-swap specifications, allowing insertion and removal without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying setup and reducing integration time.
- High Power Handling: Rated for 30 W, 125 VAC, or 30 VDC at 0.5 A, suitable for moderate power signal switching applications.
- Compact and Durable Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring robust connectivity and mechanical stability.
- PXI System Compatibility: Designed for seamless operation with ADLINK and third-party PXI controllers, chassis, and software environments.
3. Technical Specifications
- Bus Interface: PXI / CompactPCI 3U
- Card Type: 32-channel Scan/Multiplexer (Scan/MUX)
- Relay Type: Form A (SPST, Normally Open)
- Number of Channels: 32
- Bandwidth: 10 MHz (-3 dB point)
- Maximum Switching Power: 30 W
- Maximum Switching Voltage: 125 VAC / 30 VDC
- Maximum Switching Current: 0.5 A
- Connector Type: 160-pin, 2 mm pitch
- Board Dimensions: 100 mm (height) × 160 mm (depth)
- Form Factor: 3U PXI / CompactPCI
- Compliance: PICMG 2.1 R1.0 (Hot Swap)
- Operating Mode: Plug and Play, software-configurable
- Manufacturer: ADLINK Technology Inc.
4. Functionality
The PXI-7614 functions as a 32-channel scanning and multiplexing relay card within a PXI or CompactPCI system. Each of the 32 channels can be individually controlled to connect or disconnect signals, enabling flexible routing of analog or digital signals between instruments, devices under test (DUTs), and measurement equipment.
Operational Principle:
- Each Form A relay acts as a single-pole, single-throw (SPST) switch.
- The relays can be controlled programmatically through PXI software interfaces, allowing dynamic configuration of signal paths.
- The card supports scanning operations, where channels are sequentially connected to a common bus for measurement or signal acquisition.
- Multiplexing functionality allows multiple input signals to be routed to a single output channel, or vice versa, depending on system configuration.
Use Cases and Applications:
- Automated Test Equipment (ATE) systems for electronic component and subsystem testing.
- Signal routing and switching in data acquisition systems.
- Functional testing of analog and digital circuits.
- Sensor and transducer signal multiplexing.
- Laboratory instrumentation requiring flexible signal interconnection.
- Production line testing and quality assurance setups.
Compatibility:
- Fully compatible with PXI and CompactPCI 3U chassis and controllers.
- Operates with ADLINK’s PXI controllers and software tools.
- Supports integration with third-party PXI software environments such as NI LabVIEW™, NI TestStand™, and other PXI-compliant frameworks.
5. Components & Accessories
Included Items:
- PXI-7614 32-Channel Scan/MUX Form A Relay Card
- User documentation and quick start guide
- Software drivers and configuration utilities (available via ADLINK support portal)
Optional Accessories:
- PXI-compatible chassis (3U)
- PXI controller (embedded or remote)
- Signal interface cables and terminal blocks compatible with the 160-pin 2 mm connector
- Relay replacement kits (for maintenance)
- Mounting hardware and alignment guides for PXI chassis installation
Connectors:
- Primary Connector: 160-pin, 2 mm pitch PXI/cPCI backplane connector for data, control, and power interface.
- Signal Interface: Routed through the PXI backplane or via front-panel connection (depending on system configuration).
6. Installation & Setup
Requirements:
- PXI or CompactPCI 3U chassis with available slot
- Compatible PXI controller or host interface
- Supported operating system and driver software
Mounting Options:
- Standard PXI 3U slot installation using the 160-pin backplane connector.
- Hot-swappable insertion and removal per PICMG 2.1 R1.0 compliance.
Configuration Steps:
1. Power down the PXI chassis (if not using hot-swap).
2. Insert the PXI-7614 card into an available 3U slot, ensuring proper alignment with the backplane connector.
3. Secure the module using front-panel screws or latches.
4. Power on the chassis; the PXI system will automatically detect the module (Plug and Play).
5. Install ADLINK-provided drivers and software utilities.
6. Configure channel assignments and relay control parameters through the software interface.
Software Integration:
- Supports standard PXI software frameworks.
- Compatible with ADLINK’s driver libraries and APIs for C/C++, LabVIEW™, and other programming environments.
- Provides diagnostic and self-test functions for verifying relay operation and connectivity.
7. Performance & Capabilities
Switching Performance:
- Bandwidth: 10 MHz (-3 dB), suitable for low- to mid-frequency analog signals.
- Switching Power: Up to 30 W, enabling moderate power signal routing.
- Voltage and Current Ratings: 125 VAC or 30 VDC at 0.5 A maximum per channel.
- Relay Type: Mechanical Form A relays ensure low contact resistance and high isolation.
Speed and Efficiency:
- Relay switching time typically in the millisecond range (dependent on relay characteristics).
- Efficient signal routing with minimal crosstalk and insertion loss within the specified bandwidth.
- Optimized for high reliability and long operational life in continuous test environments.
Limitations:
- Not intended for high-frequency RF switching beyond 10 MHz.
- Maximum current limited to 0.5 A per channel; higher loads require external switching solutions.
- Mechanical relays subject to wear over extended use; periodic maintenance recommended.
Reliability:
- Designed for industrial-grade operation with robust mechanical construction.
- High-quality relays rated for thousands of switching cycles.
- Stable performance across a wide range of environmental conditions (within PXI chassis specifications).
8. Standards & Compliance
- PXI Compliance: Fully compliant with PXI specifications for mechanical, electrical, and software interfaces.
- CompactPCI Compliance: Meets CompactPCI 3U form factor and electrical standards.
- Hot Swap Compliance: Conforms to PICMG 2.1 R1.0 for hot-swappable modules.
- Safety and Electrical Ratings:
- Maximum 125 VAC / 30 VDC switching voltage
- Maximum 0.5 A switching current
- Maximum 30 W switching power
- Environmental and Quality Standards:
- Manufactured under ISO 9001 quality management systems.
- RoHS-compliant materials and lead-free soldering processes.
- Regulatory Compliance:
- CE marking for electromagnetic compatibility and safety.
- FCC compliance for emissions and interference control (typical for PXI modules).
9. Additional Information
Warranty:
- Standard manufacturer’s warranty (typically one year, extendable depending on region and distributor).
- Covers defects in materials and workmanship under normal operating conditions.
Support:
- Technical support available through ADLINK’s global service network.
- Online resources include driver downloads, manuals, and application notes.
- Firmware and software updates provided via ADLINK’s support portal.
Maintenance:
- Periodic inspection of relay operation recommended for high-duty-cycle applications.
- Replacement relays or modules available through authorized service centers.
- Keep connectors clean and free from dust to maintain signal integrity.
Updates and Lifecycle:
- Supported within ADLINK’s PXI product roadmap for long-term availability.
- Compatible with future PXI software and hardware revisions.
- Firmware and driver updates ensure continued compatibility with evolving test systems.
Summary
The ADLINK PXI-7614 is a PXI/cPCI 3U 32-channel Scan/Multiplexer Form A Relay Card engineered for precision signal switching and multiplexing in automated test and measurement environments. With its 10 MHz bandwidth, 30 W power rating, and hot-swappable PXI interface, it delivers a balance of performance, reliability, and flexibility. The module’s Form A relays provide dependable mechanical switching, while Plug and Play functionality simplifies integration into PXI systems.
Designed to meet PICMG 2.1 R1.0 and PXI standards, the PXI-7614 ensures compatibility with a wide range of PXI chassis and controllers. Its 160-pin 2 mm connector and 100 × 160 mm 3U form factor make it ideal for dense, modular test setups. Whether used for signal scanning, routing, or multiplexing, the PXI-7614 offers a robust, standards-compliant solution for engineers and system integrators seeking reliable switching performance in compact, scalable PXI platforms.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.