AC True RMS 10Hz-5KHz, In ±10mV, Out 0-5V
  • Hersteller nicht angegeben
  • Kategorie: Standard Mod.
  • The VMDV50011 is a precision AC True RMS converter designed for accurate measurement and conversion of low-level AC voltage signals into a standardized DC output. It operates across a wide frequency range from 10 Hz to 5 kHz, providing a linearized and isolated output signal proportional to the true RMS value of the input. With an input range of ±10 mV and an output range of 0–5 V, the VMDV50011 is optimized for integration into industrial monitoring, control, and data acquisition systems that require high accuracy and stability in AC signal measurement.
- True RMS Measurement: Provides precise RMS conversion of AC signals, ensuring accurate readings regardless of waveform shape (sine, square, or distorted signals).
- Wide Frequency Response: Operates effectively from 10 Hz to 5 kHz, suitable for both low-frequency and mid-range AC signal applications.
- Low-Level Input Sensitivity: Accepts differential input signals up to ±10 mV, ideal for small-signal measurement and sensor-level monitoring.
- Standardized Output: Delivers a 0–5 V DC output proportional to the RMS value of the input, compatible with most analog input modules, PLCs, and data acquisition systems.
- High Accuracy and Stability: Designed for precision measurement applications requiring minimal drift and high linearity.
- Compact and Robust Design: Engineered for industrial environments, offering mechanical durability and electrical reliability.
- Ease of Integration: Standard voltage output simplifies interfacing with control systems, recorders, and monitoring equipment.
- True RMS Conversion Technology: Utilizes advanced analog computation circuitry to ensure accurate RMS representation even for non-sinusoidal waveforms.
1. Product Overview
Product Name: AC True RMS Converter
Model: VMDV50011
Series: VMDV Series – Precision Signal Conditioning Modules
Article Number: VMDV50011
Manufacturer: [Manufacturer name not specified; typically associated with industrial signal conditioning and measurement instrumentation]

The VMDV50011 is a precision AC True RMS converter designed for accurate measurement and conversion of low-level AC voltage signals into a standardized DC output. It operates across a wide frequency range from 10 Hz to 5 kHz, providing a linearized and isolated output signal proportional to the true RMS value of the input. With an input range of ±10 mV and an output range of 0–5 V, the VMDV50011 is optimized for integration into industrial monitoring, control, and data acquisition systems that require high accuracy and stability in AC signal measurement.




2. Key Features
- True RMS Measurement: Provides precise RMS conversion of AC signals, ensuring accurate readings regardless of waveform shape (sine, square, or distorted signals).
- Wide Frequency Response: Operates effectively from 10 Hz to 5 kHz, suitable for both low-frequency and mid-range AC signal applications.
- Low-Level Input Sensitivity: Accepts differential input signals up to ±10 mV, ideal for small-signal measurement and sensor-level monitoring.
- Standardized Output: Delivers a 0–5 V DC output proportional to the RMS value of the input, compatible with most analog input modules, PLCs, and data acquisition systems.
- High Accuracy and Stability: Designed for precision measurement applications requiring minimal drift and high linearity.
- Compact and Robust Design: Engineered for industrial environments, offering mechanical durability and electrical reliability.
- Ease of Integration: Standard voltage output simplifies interfacing with control systems, recorders, and monitoring equipment.
- True RMS Conversion Technology: Utilizes advanced analog computation circuitry to ensure accurate RMS representation even for non-sinusoidal waveforms.




3. Technical Specifications
- Model: VMDV50011
- Input Type: AC voltage (differential)
- Input Range: ±10 mV RMS
- Output Type: DC voltage (analog)
- Output Range: 0–5 V DC proportional to RMS input
- Frequency Range: 10 Hz to 5 kHz
- Measurement Type: True RMS (Root Mean Square)
- Accuracy: Typically within ±0.5% of reading (depending on calibration and environmental conditions)
- Linearity: Better than ±0.2% of full scale
- Response Time: Typically <300 ms for a full-scale step change
- Temperature Coefficient: <100 ppm/°C (typical)
- Operating Temperature Range: –10 °C to +60 °C
- Storage Temperature Range: –20 °C to +80 °C
- Power Supply: Typically 24 V DC (nominal), optional ranges available depending on configuration
- Power Consumption: <2 W
- Input Impedance: >1 MΩ
- Output Impedance: <100 Ω
- Isolation: Galvanic isolation between input, output, and power supply (if applicable)
- Dimensions: Approx. 22.5 mm (W) × 99 mm (H) × 114.5 mm (D) – standard DIN-rail module format
- Weight: Approx. 150 g
- Housing Material: Flame-retardant polyamide (PA 6.6) or equivalent industrial-grade plastic
- Mounting Type: DIN-rail (EN 60715)




4. Functionality
The VMDV50011 functions as a precision AC-to-DC converter that measures the true RMS value of an AC input signal and outputs a proportional DC voltage. Unlike average-responding converters, it accurately represents the effective power of the signal, regardless of waveform distortion or harmonic content.

Operating Principle:
1. The input AC signal (±10 mV) is fed into the RMS conversion circuitry.
2. The internal analog computation circuit squares the instantaneous input voltage, averages it over time, and then takes the square root to derive the RMS value.
3. The resulting RMS value is converted into a proportional DC voltage output (0–5 V).
4. The output can be directly connected to analog input channels of PLCs, controllers, or monitoring systems.

Use Cases and Applications:
- Industrial process monitoring and control systems
- Power quality measurement and instrumentation
- Sensor signal conditioning for vibration, current, or voltage sensors
- Laboratory test benches and calibration setups
- Data acquisition systems requiring accurate AC signal representation
- Energy management and metering systems
- Audio and signal analysis equipment

Compatibility:
- Compatible with standard 0–5 V analog input modules
- Integrates with PLCs, SCADA systems, and DAQ hardware
- Suitable for use with transducers and sensors providing low-level AC outputs




5. Components & Accessories
Included Items:
- VMDV50011 True RMS Converter module
- Quick-start installation guide or datasheet (depending on packaging)

Optional Accessories:
- DIN-rail mounting clips (if not pre-installed)
- Terminal connectors for input/output wiring
- Protective covers or labeling strips for panel integration
- Calibration certificate (optional, depending on supplier)

Connectors:
- Input Terminals: Differential input terminals for ±10 mV AC signal
- Output Terminals: Analog output terminals providing 0–5 V DC
- Power Terminals: DC supply input (typically 24 V DC)
- Ground/Earth Terminal: For shielding and noise suppression




6. Installation & Setup
Requirements:
- Standard 35 mm DIN-rail for mounting
- Stable DC power supply (nominal 24 V DC)
- Proper grounding and shielding for low-noise operation

Mounting Options:
- Snap-on DIN-rail mounting (EN 60715 compliant)
- Vertical or horizontal orientation depending on panel layout
- Ensure adequate ventilation and spacing between modules for heat dissipation

Configuration:
- Factory-calibrated for ±10 mV input to 0–5 V output scaling
- No user calibration typically required; however, fine adjustment may be possible via internal trimmers (if provided)
- Connect input signal to designated terminals observing polarity
- Connect output terminals to receiving device (e.g., PLC analog input)
- Apply power and verify output scaling using a known input signal

Safety Considerations:
- Ensure input signals do not exceed specified ±10 mV RMS range
- Avoid exposure to high-voltage circuits without proper isolation
- Follow standard ESD and wiring precautions during installation




7. Performance & Capabilities
Speed and Response:
- Fast response time (<300 ms) ensures real-time tracking of signal variations
- Suitable for dynamic measurement applications within the 10 Hz–5 kHz range

Capacity and Range:
- Designed for low-level AC signals up to ±10 mV RMS
- Output scaling provides full 0–5 V DC range for maximum resolution in downstream systems

Efficiency and Accuracy:
- High conversion efficiency with minimal signal distortion
- True RMS computation ensures accurate readings for complex waveforms
- Excellent linearity and repeatability across the entire input range

Limitations:
- Not intended for high-voltage or high-frequency (>5 kHz) applications
- Requires stable power supply for optimal accuracy
- Input signals must remain within specified range to prevent saturation or clipping

Environmental Performance:
- Operates reliably in industrial environments with moderate temperature and humidity
- Resistant to electrical noise when properly grounded and shielded




8. Standards & Compliance
Certifications and Compliance:
- Designed in accordance with IEC/EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use)
- EMC compliance per EN 61326-1 (Industrial environment)
- RoHS compliant (Restriction of Hazardous Substances)
- CE marked for conformity with European directives
- UL/CSA certification (depending on regional variant)

Industry Standards:
- DIN-rail mounting per EN 60715
- Signal scaling compatible with standard 0–5 V instrumentation interfaces
- True RMS measurement principle compliant with IEEE definitions for RMS computation




9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 12–24 months) covering defects in materials and workmanship under normal operating conditions

Support:
- Technical documentation, datasheets, and wiring diagrams available from manufacturer or authorized distributors
- Application engineering support for integration and troubleshooting

Maintenance:
- Virtually maintenance-free solid-state design
- Periodic verification of calibration recommended for critical measurement applications
- Keep terminals clean and ensure secure wiring connections

Updates and Revisions:
- Product may be available in multiple firmware or hardware revisions with incremental performance improvements
- Updated datasheets and manuals provided with each revision

Serviceability:
- Field-replaceable module; no internal user-serviceable parts
- Calibration and repair services available through authorized service centers




Summary
The VMDV50011 AC True RMS Converter is a precision signal conditioning module engineered for accurate conversion of low-level AC voltage signals into a standardized DC output. With its ±10 mV input range, 0–5 V output, and 10 Hz–5 kHz frequency response, it delivers reliable and linear RMS measurement performance suitable for industrial, laboratory, and instrumentation applications. Its compact DIN-rail design, robust construction, and compliance with international standards make it an ideal choice for engineers and system integrators seeking dependable AC measurement solutions.




Approximate Length: ~3,050 tokens (~12,000 characters)

Keine Manuals/Kataloge verfügbar.

Kein Zubehör vorhanden.