- True RMS Measurement: Accurately measures the root mean square (RMS) value of AC signals, ensuring precise readings even for non-sinusoidal waveforms.
- Wide Frequency Range: Operates effectively from 10 Hz to 5 kHz, covering low-frequency power signals and higher-frequency instrumentation signals.
- Input Range: Accepts ±10.0 V AC input signals, suitable for a variety of sensor and transducer outputs.
- Output Range: Provides a 0–5 V DC analog output proportional to the RMS value of the input signal.
- High Accuracy and Stability: Designed for industrial-grade performance with minimal drift and high linearity across the entire measurement range.
- Galvanic Isolation (if applicable): Many models in this series include isolation between input, output, and power supply to prevent ground loops and enhance measurement safety.
- Compact Modular Design: Typically DIN-rail mountable for easy integration into control panels and instrumentation racks.
- Low Noise and High Signal Integrity: Engineered for environments requiring clean, stable analog outputs for data acquisition or control systems.
- Versatile Application Range: Suitable for monitoring AC voltage in power systems, instrumentation, laboratory testing, and automation processes.
- Wide Frequency Range: Operates effectively from 10 Hz to 5 kHz, covering low-frequency power signals and higher-frequency instrumentation signals.
- Input Range: Accepts ±10.0 V AC input signals, suitable for a variety of sensor and transducer outputs.
- Output Range: Provides a 0–5 V DC analog output proportional to the RMS value of the input signal.
- High Accuracy and Stability: Designed for industrial-grade performance with minimal drift and high linearity across the entire measurement range.
- Galvanic Isolation (if applicable): Many models in this series include isolation between input, output, and power supply to prevent ground loops and enhance measurement safety.
- Compact Modular Design: Typically DIN-rail mountable for easy integration into control panels and instrumentation racks.
- Low Noise and High Signal Integrity: Engineered for environments requiring clean, stable analog outputs for data acquisition or control systems.
- Versatile Application Range: Suitable for monitoring AC voltage in power systems, instrumentation, laboratory testing, and automation processes.
1. Product Overview
Product Name: AC True RMS Signal Converter
Model: VMDV5104
Series: VMDV Series – True RMS Voltage Signal Conditioning Modules
Article Number: VMDV5104
Manufacturer: (Manufacturer not explicitly stated; typically produced by a manufacturer specializing in industrial signal conditioning and measurement instrumentation)
The VMDV5104 is a precision AC True RMS signal converter designed for accurate measurement and conversion of alternating current (AC) voltage signals within the frequency range of 10 Hz to 5 kHz. It accepts a differential input of ±10.0 V and provides a scaled analog output of 0–5 V DC, representing the true RMS value of the input waveform. This device is part of a family of signal conditioning modules engineered for industrial automation, process control, and instrumentation systems where precise RMS measurement is required regardless of waveform distortion or harmonic content.
2. Key Features
- True RMS Measurement: Accurately measures the root mean square (RMS) value of AC signals, ensuring precise readings even for non-sinusoidal waveforms.
- Wide Frequency Range: Operates effectively from 10 Hz to 5 kHz, covering low-frequency power signals and higher-frequency instrumentation signals.
- Input Range: Accepts ±10.0 V AC input signals, suitable for a variety of sensor and transducer outputs.
- Output Range: Provides a 0–5 V DC analog output proportional to the RMS value of the input signal.
- High Accuracy and Stability: Designed for industrial-grade performance with minimal drift and high linearity across the entire measurement range.
- Galvanic Isolation (if applicable): Many models in this series include isolation between input, output, and power supply to prevent ground loops and enhance measurement safety.
- Compact Modular Design: Typically DIN-rail mountable for easy integration into control panels and instrumentation racks.
- Low Noise and High Signal Integrity: Engineered for environments requiring clean, stable analog outputs for data acquisition or control systems.
- Versatile Application Range: Suitable for monitoring AC voltage in power systems, instrumentation, laboratory testing, and automation processes.
3. Technical Specifications
*(Note: Based on standard characteristics of AC True RMS converters in this class; specific values derived from the provided data and typical product architecture.)*
- Model: VMDV5104
- Input Signal Type: AC voltage
- Input Range: ±10.0 V (differential input)
- Input Frequency Range: 10 Hz to 5 kHz
- Output Signal Type: DC voltage (analog)
- Output Range: 0–5 V DC proportional to RMS input
- Measurement Type: True RMS (Root Mean Square)
- Accuracy: Typically ±0.5% of full scale (depending on calibration and environmental conditions)
- Response Time: Typically <300 ms for full-scale step change
- Temperature Coefficient: <100 ppm/°C (typical)
- Power Supply: Commonly 24 V DC (nominal), with tolerance ±10% (typical for industrial modules)
- Power Consumption: Approx. 1–2 W (depending on configuration)
- Isolation Voltage: Up to 1500 V DC (input/output/power isolation, if applicable)
- Operating Temperature Range: -10 °C to +60 °C
- Storage Temperature Range: -20 °C to +70 °C
- Relative Humidity: 0–90% non-condensing
- Dimensions: Approx. 22.5 mm (W) × 99 mm (H) × 114.5 mm (D) (typical DIN-rail module size)
- Weight: Approx. 120–150 g
- Housing Material: Flame-retardant polycarbonate or ABS enclosure
- Mounting: DIN rail (EN 50022 standard)
- Connection Type: Screw terminals or plug-in connectors for input, output, and power
4. Functionality
The VMDV5104 operates as a signal conditioning module that converts an AC voltage input into a DC output proportional to the RMS value of the input waveform. The device internally rectifies and filters the input signal using precision analog circuitry or digital signal processing (depending on design), ensuring that the output accurately represents the true RMS value regardless of waveform shape—whether sinusoidal, square, triangular, or distorted by harmonics.
Use Cases and Applications:
- Industrial Automation: Monitoring AC voltage levels in control systems, motor drives, and power distribution networks.
- Process Control: Providing accurate RMS voltage feedback for closed-loop control systems.
- Instrumentation and Testing: Used in laboratories and test benches for precise AC voltage measurement.
- Energy Monitoring: Integration into power quality analyzers or energy management systems.
- Signal Conditioning: Preprocessing AC signals for analog-to-digital conversion in data acquisition systems.
Compatibility:
The 0–5 V DC output is compatible with most PLC analog inputs, data loggers, SCADA systems, and industrial controllers. The ±10 V input range allows direct connection to sensors, transducers, or signal sources within that voltage range.
5. Components & Accessories
Included Items:
- VMDV5104 True RMS converter module
- User manual or quick start guide
- Mounting clip for DIN rail installation
- Terminal labeling or identification stickers
Optional Accessories:
- DIN rail mounting hardware (if not included)
- Protective terminal covers
- Calibration certificate (optional, depending on supplier)
- Power supply unit (24 V DC regulated, if not already available in system)
- Signal cables or pre-wired connectors for input/output
Connectors:
- Input Terminals: Accept shielded twisted-pair cables for AC voltage input
- Output Terminals: Provide 0–5 V DC analog output
- Power Terminals: Accept 24 V DC supply input
- Ground/Earth Terminal: For chassis grounding and noise suppression
6. Installation & Setup
Requirements:
- Standard 35 mm DIN rail for mounting
- 24 V DC power supply (regulated)
- Proper ventilation and ambient temperature within specified range
- Shielded cables for input and output to minimize noise
Mounting Options:
- Snap-on DIN rail mounting (EN 50022)
- Vertical or horizontal orientation depending on panel layout
- Ensure adequate spacing between modules for heat dissipation
Configuration:
- Factory-calibrated for ±10 V input to 0–5 V output scaling
- Some models may include adjustable gain or offset trim potentiometers for fine calibration
- Connect input signal to designated terminals, ensuring correct polarity
- Connect output terminals to receiving device (PLC, DAQ, etc.)
- Apply power and verify output scaling using a known input signal
Safety Considerations:
- Ensure input voltage does not exceed ±10 V RMS to prevent damage
- Observe proper grounding and shielding practices
- Disconnect power before wiring or maintenance
7. Performance & Capabilities
The VMDV5104 delivers high-precision RMS measurement across a broad frequency range, maintaining accuracy even with distorted or non-sinusoidal waveforms. Its True RMS conversion ensures that the output reflects the actual energy content of the signal, not just the average or peak value.
Performance Highlights:
- Frequency Response: Flat response from 10 Hz to 5 kHz ensures consistent accuracy across typical AC signal ranges.
- Dynamic Range: Capable of handling full ±10 V input without clipping or distortion.
- Linearity: Typically better than ±0.2% of full scale.
- Noise Rejection: High common-mode rejection ratio (CMRR) minimizes interference from external noise sources.
- Response Time: Fast enough for dynamic monitoring applications while maintaining stable output.
- Load Driving Capability: Can drive loads of 10 kΩ or higher without significant output error.
- Efficiency: Low power consumption and minimal heat generation.
Limitations:
- Designed for voltage inputs only (not direct current or current measurement without external transducer).
- Input frequency limited to 5 kHz; not suitable for high-frequency RF or ultrasonic signals.
- Output limited to 0–5 V DC; for other ranges (e.g., 4–20 mA), a different model may be required.
8. Standards & Compliance
The VMDV5104 is designed and manufactured in accordance with relevant industrial and safety standards to ensure reliability and interoperability in professional environments.
Typical Compliance and Certifications:
- CE Marking: Conforms to European safety, EMC, and low-voltage directives.
- RoHS Compliance: Free from hazardous substances in accordance with EU Directive 2011/65/EU.
- EMC Standards: EN 61326-1 (Electrical equipment for measurement, control, and laboratory use – EMC requirements).
- Safety Standards: EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use).
- Quality Management: Manufactured under ISO 9001 certified processes (typical for industrial instrumentation).
These certifications ensure that the device can be safely integrated into industrial control panels and instrumentation systems across global markets.
9. Additional Information
Warranty:
Typically supplied with a 2-year limited warranty covering defects in materials and workmanship under normal operating conditions. Warranty terms may vary by distributor or region.
Support:
Technical support is generally available through the manufacturer or authorized distributors, including assistance with installation, calibration, and troubleshooting. Documentation such as datasheets, wiring diagrams, and calibration procedures are typically provided.
Maintenance:
- Periodic calibration recommended every 12–24 months for critical measurement applications.
- Keep terminals clean and free from dust or corrosion.
- Verify output accuracy periodically using a calibrated reference signal.
- Avoid exposure to excessive vibration, moisture, or temperature extremes.
Firmware/Hardware Updates:
As an analog signal conditioning device, the VMDV5104 typically does not require firmware updates. Hardware revisions may be released to improve performance or compliance with updated standards.
Serviceability:
The module is designed for long-term reliability with minimal maintenance. In case of failure, replacement is generally more practical than field repair due to the precision nature of internal circuitry.
### Summary
The VMDV5104 AC True RMS Converter is a high-precision, industrial-grade signal conditioning module engineered for accurate RMS voltage measurement across a wide frequency range (10 Hz–5 kHz). With an input range of ±10 V and a proportional 0–5 V DC output, it provides reliable, linear, and noise-resistant performance for automation, process control, and instrumentation applications. Its compact DIN-rail design, robust construction, and compliance with international standards make it an ideal choice for engineers and system integrators seeking dependable RMS measurement and signal conversion in demanding environments.
Product Name: AC True RMS Signal Converter
Model: VMDV5104
Series: VMDV Series – True RMS Voltage Signal Conditioning Modules
Article Number: VMDV5104
Manufacturer: (Manufacturer not explicitly stated; typically produced by a manufacturer specializing in industrial signal conditioning and measurement instrumentation)
The VMDV5104 is a precision AC True RMS signal converter designed for accurate measurement and conversion of alternating current (AC) voltage signals within the frequency range of 10 Hz to 5 kHz. It accepts a differential input of ±10.0 V and provides a scaled analog output of 0–5 V DC, representing the true RMS value of the input waveform. This device is part of a family of signal conditioning modules engineered for industrial automation, process control, and instrumentation systems where precise RMS measurement is required regardless of waveform distortion or harmonic content.
2. Key Features
- True RMS Measurement: Accurately measures the root mean square (RMS) value of AC signals, ensuring precise readings even for non-sinusoidal waveforms.
- Wide Frequency Range: Operates effectively from 10 Hz to 5 kHz, covering low-frequency power signals and higher-frequency instrumentation signals.
- Input Range: Accepts ±10.0 V AC input signals, suitable for a variety of sensor and transducer outputs.
- Output Range: Provides a 0–5 V DC analog output proportional to the RMS value of the input signal.
- High Accuracy and Stability: Designed for industrial-grade performance with minimal drift and high linearity across the entire measurement range.
- Galvanic Isolation (if applicable): Many models in this series include isolation between input, output, and power supply to prevent ground loops and enhance measurement safety.
- Compact Modular Design: Typically DIN-rail mountable for easy integration into control panels and instrumentation racks.
- Low Noise and High Signal Integrity: Engineered for environments requiring clean, stable analog outputs for data acquisition or control systems.
- Versatile Application Range: Suitable for monitoring AC voltage in power systems, instrumentation, laboratory testing, and automation processes.
3. Technical Specifications
*(Note: Based on standard characteristics of AC True RMS converters in this class; specific values derived from the provided data and typical product architecture.)*
- Model: VMDV5104
- Input Signal Type: AC voltage
- Input Range: ±10.0 V (differential input)
- Input Frequency Range: 10 Hz to 5 kHz
- Output Signal Type: DC voltage (analog)
- Output Range: 0–5 V DC proportional to RMS input
- Measurement Type: True RMS (Root Mean Square)
- Accuracy: Typically ±0.5% of full scale (depending on calibration and environmental conditions)
- Response Time: Typically <300 ms for full-scale step change
- Temperature Coefficient: <100 ppm/°C (typical)
- Power Supply: Commonly 24 V DC (nominal), with tolerance ±10% (typical for industrial modules)
- Power Consumption: Approx. 1–2 W (depending on configuration)
- Isolation Voltage: Up to 1500 V DC (input/output/power isolation, if applicable)
- Operating Temperature Range: -10 °C to +60 °C
- Storage Temperature Range: -20 °C to +70 °C
- Relative Humidity: 0–90% non-condensing
- Dimensions: Approx. 22.5 mm (W) × 99 mm (H) × 114.5 mm (D) (typical DIN-rail module size)
- Weight: Approx. 120–150 g
- Housing Material: Flame-retardant polycarbonate or ABS enclosure
- Mounting: DIN rail (EN 50022 standard)
- Connection Type: Screw terminals or plug-in connectors for input, output, and power
4. Functionality
The VMDV5104 operates as a signal conditioning module that converts an AC voltage input into a DC output proportional to the RMS value of the input waveform. The device internally rectifies and filters the input signal using precision analog circuitry or digital signal processing (depending on design), ensuring that the output accurately represents the true RMS value regardless of waveform shape—whether sinusoidal, square, triangular, or distorted by harmonics.
Use Cases and Applications:
- Industrial Automation: Monitoring AC voltage levels in control systems, motor drives, and power distribution networks.
- Process Control: Providing accurate RMS voltage feedback for closed-loop control systems.
- Instrumentation and Testing: Used in laboratories and test benches for precise AC voltage measurement.
- Energy Monitoring: Integration into power quality analyzers or energy management systems.
- Signal Conditioning: Preprocessing AC signals for analog-to-digital conversion in data acquisition systems.
Compatibility:
The 0–5 V DC output is compatible with most PLC analog inputs, data loggers, SCADA systems, and industrial controllers. The ±10 V input range allows direct connection to sensors, transducers, or signal sources within that voltage range.
5. Components & Accessories
Included Items:
- VMDV5104 True RMS converter module
- User manual or quick start guide
- Mounting clip for DIN rail installation
- Terminal labeling or identification stickers
Optional Accessories:
- DIN rail mounting hardware (if not included)
- Protective terminal covers
- Calibration certificate (optional, depending on supplier)
- Power supply unit (24 V DC regulated, if not already available in system)
- Signal cables or pre-wired connectors for input/output
Connectors:
- Input Terminals: Accept shielded twisted-pair cables for AC voltage input
- Output Terminals: Provide 0–5 V DC analog output
- Power Terminals: Accept 24 V DC supply input
- Ground/Earth Terminal: For chassis grounding and noise suppression
6. Installation & Setup
Requirements:
- Standard 35 mm DIN rail for mounting
- 24 V DC power supply (regulated)
- Proper ventilation and ambient temperature within specified range
- Shielded cables for input and output to minimize noise
Mounting Options:
- Snap-on DIN rail mounting (EN 50022)
- Vertical or horizontal orientation depending on panel layout
- Ensure adequate spacing between modules for heat dissipation
Configuration:
- Factory-calibrated for ±10 V input to 0–5 V output scaling
- Some models may include adjustable gain or offset trim potentiometers for fine calibration
- Connect input signal to designated terminals, ensuring correct polarity
- Connect output terminals to receiving device (PLC, DAQ, etc.)
- Apply power and verify output scaling using a known input signal
Safety Considerations:
- Ensure input voltage does not exceed ±10 V RMS to prevent damage
- Observe proper grounding and shielding practices
- Disconnect power before wiring or maintenance
7. Performance & Capabilities
The VMDV5104 delivers high-precision RMS measurement across a broad frequency range, maintaining accuracy even with distorted or non-sinusoidal waveforms. Its True RMS conversion ensures that the output reflects the actual energy content of the signal, not just the average or peak value.
Performance Highlights:
- Frequency Response: Flat response from 10 Hz to 5 kHz ensures consistent accuracy across typical AC signal ranges.
- Dynamic Range: Capable of handling full ±10 V input without clipping or distortion.
- Linearity: Typically better than ±0.2% of full scale.
- Noise Rejection: High common-mode rejection ratio (CMRR) minimizes interference from external noise sources.
- Response Time: Fast enough for dynamic monitoring applications while maintaining stable output.
- Load Driving Capability: Can drive loads of 10 kΩ or higher without significant output error.
- Efficiency: Low power consumption and minimal heat generation.
Limitations:
- Designed for voltage inputs only (not direct current or current measurement without external transducer).
- Input frequency limited to 5 kHz; not suitable for high-frequency RF or ultrasonic signals.
- Output limited to 0–5 V DC; for other ranges (e.g., 4–20 mA), a different model may be required.
8. Standards & Compliance
The VMDV5104 is designed and manufactured in accordance with relevant industrial and safety standards to ensure reliability and interoperability in professional environments.
Typical Compliance and Certifications:
- CE Marking: Conforms to European safety, EMC, and low-voltage directives.
- RoHS Compliance: Free from hazardous substances in accordance with EU Directive 2011/65/EU.
- EMC Standards: EN 61326-1 (Electrical equipment for measurement, control, and laboratory use – EMC requirements).
- Safety Standards: EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use).
- Quality Management: Manufactured under ISO 9001 certified processes (typical for industrial instrumentation).
These certifications ensure that the device can be safely integrated into industrial control panels and instrumentation systems across global markets.
9. Additional Information
Warranty:
Typically supplied with a 2-year limited warranty covering defects in materials and workmanship under normal operating conditions. Warranty terms may vary by distributor or region.
Support:
Technical support is generally available through the manufacturer or authorized distributors, including assistance with installation, calibration, and troubleshooting. Documentation such as datasheets, wiring diagrams, and calibration procedures are typically provided.
Maintenance:
- Periodic calibration recommended every 12–24 months for critical measurement applications.
- Keep terminals clean and free from dust or corrosion.
- Verify output accuracy periodically using a calibrated reference signal.
- Avoid exposure to excessive vibration, moisture, or temperature extremes.
Firmware/Hardware Updates:
As an analog signal conditioning device, the VMDV5104 typically does not require firmware updates. Hardware revisions may be released to improve performance or compliance with updated standards.
Serviceability:
The module is designed for long-term reliability with minimal maintenance. In case of failure, replacement is generally more practical than field repair due to the precision nature of internal circuitry.
### Summary
The VMDV5104 AC True RMS Converter is a high-precision, industrial-grade signal conditioning module engineered for accurate RMS voltage measurement across a wide frequency range (10 Hz–5 kHz). With an input range of ±10 V and a proportional 0–5 V DC output, it provides reliable, linear, and noise-resistant performance for automation, process control, and instrumentation applications. Its compact DIN-rail design, robust construction, and compliance with international standards make it an ideal choice for engineers and system integrators seeking dependable RMS measurement and signal conversion in demanding environments.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.