LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- Thermocouple Input (Type T): Accepts direct connection from Type T thermocouples (Copper-Constantan).
- Input Range: 0°C to +200°C, optimized for low-temperature measurement applications.
- Output Signal: Linearized 0–5 V DC analog output, directly proportional to the measured temperature.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion.
- Galvanic Isolation: Provides high-level isolation between input, output, and power supply, typically rated at 1500 V rms or higher, protecting downstream equipment and reducing ground loop interference.
- High Accuracy and Stability: Designed for precision measurement with low drift and high common-mode rejection ratio (CMRR).
- Compact 5B Form Factor: Standardized plug-in module compatible with 5B backplanes and carriers.
- Ease of Integration: Standard 0–5 V output allows direct interface with analog input channels of data acquisition systems, PLCs, and control systems.
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance over extended temperature ranges.
- Low Power Consumption: Optimized for multi-channel systems with minimal heat generation.
- Plug-and-Play Compatibility: Works with standard 5B backplanes, simplifying installation and replacement.
- Input Range: 0°C to +200°C, optimized for low-temperature measurement applications.
- Output Signal: Linearized 0–5 V DC analog output, directly proportional to the measured temperature.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion.
- Galvanic Isolation: Provides high-level isolation between input, output, and power supply, typically rated at 1500 V rms or higher, protecting downstream equipment and reducing ground loop interference.
- High Accuracy and Stability: Designed for precision measurement with low drift and high common-mode rejection ratio (CMRR).
- Compact 5B Form Factor: Standardized plug-in module compatible with 5B backplanes and carriers.
- Ease of Integration: Standard 0–5 V output allows direct interface with analog input channels of data acquisition systems, PLCs, and control systems.
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance over extended temperature ranges.
- Low Power Consumption: Optimized for multi-channel systems with minimal heat generation.
- Plug-and-Play Compatibility: Works with standard 5B backplanes, simplifying installation and replacement.
1. Product Overview
Name: 5B47-T07 Thermocouple Input Module
Model: 5B47-T07
Series: 5B Series Analog Signal Conditioning Modules
Article Number: 5B47-T07
Manufacturer: (Typically produced by Analog Devices or compatible 5B module manufacturers; part of the 5B signal conditioning family widely used in industrial and laboratory data acquisition systems.)
The 5B47-T07 is a precision thermocouple input module designed for direct connection to Type T thermocouples. It provides a linearized, isolated, and amplified analog output signal of 0–5 V, corresponding to an input temperature range of 0°C to +200°C. The module belongs to the 5B Series, a family of compact, plug-in signal conditioning modules used for accurate, isolated measurement of various sensor types in industrial, laboratory, and process control environments.
2. Key Features
- Thermocouple Input (Type T): Accepts direct connection from Type T thermocouples (Copper-Constantan).
- Input Range: 0°C to +200°C, optimized for low-temperature measurement applications.
- Output Signal: Linearized 0–5 V DC analog output, directly proportional to the measured temperature.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion.
- Galvanic Isolation: Provides high-level isolation between input, output, and power supply, typically rated at 1500 V rms or higher, protecting downstream equipment and reducing ground loop interference.
- High Accuracy and Stability: Designed for precision measurement with low drift and high common-mode rejection ratio (CMRR).
- Compact 5B Form Factor: Standardized plug-in module compatible with 5B backplanes and carriers.
- Ease of Integration: Standard 0–5 V output allows direct interface with analog input channels of data acquisition systems, PLCs, and control systems.
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance over extended temperature ranges.
- Low Power Consumption: Optimized for multi-channel systems with minimal heat generation.
- Plug-and-Play Compatibility: Works with standard 5B backplanes, simplifying installation and replacement.
3. Technical Specifications
*(Typical values for 5B47-T07 module; actual performance may vary slightly depending on manufacturer and configuration.)*
- Input Type: Thermocouple Type T (Copper-Constantan)
- Input Range: 0°C to +200°C
- Output Range: 0 V to +5 V DC (linearized)
- Transfer Function: 0°C → 0 V; +200°C → +5 V
- Accuracy: ±0.1% of full scale (typical)
- Linearity Error: ±0.05% of full scale (typical)
- Cold Junction Compensation: Internal, automatic
- Isolation Voltage: 1500 V rms (input-to-output and input-to-power)
- Common Mode Rejection Ratio (CMRR): >120 dB at 50/60 Hz
- Input Impedance: >10 MΩ
- Output Impedance: <1 Ω
- Bandwidth: DC to 3 Hz (typical, limited for noise reduction)
- Response Time: <100 ms to 90% of final value
- Power Supply Voltage: +5 V DC ±5% (supplied via 5B backplane)
- Power Consumption: Typically 25–35 mW per module
- Operating Temperature Range: –40°C to +85°C
- Storage Temperature Range: –40°C to +85°C
- Relative Humidity: 0–95%, non-condensing
- Dimensions: Approx. 60 mm (L) × 15 mm (W) × 25 mm (H) (standard 5B module size)
- Weight: Approximately 25–30 g
- Material: Molded thermoplastic housing, flame-retardant, UL94V-0 rated
- Mounting: Plug-in module for 5B backplane or DIN-rail carrier
4. Functionality
The 5B47-T07 operates as a precision signal conditioning interface between a Type T thermocouple sensor and a data acquisition or control system. The thermocouple generates a small voltage proportional to the temperature difference between its measuring junction and reference junction. The module performs several key functions:
1. Signal Amplification: The low-level thermocouple voltage (in microvolts per degree Celsius) is amplified to a standard 0–5 V output range suitable for most analog input devices.
2. Cold Junction Compensation (CJC): The module includes an internal temperature sensor that measures the ambient temperature at the input terminals, automatically compensating for the reference junction temperature.
3. Linearization: The nonlinear thermocouple response is electronically linearized to produce a direct, proportional voltage output corresponding to temperature.
4. Isolation: The module provides galvanic isolation between the thermocouple input, output signal, and power supply, preventing ground loops and ensuring measurement integrity.
5. Filtering: Internal low-pass filtering minimizes noise and interference from industrial environments.
Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement systems
- Environmental test chambers
- HVAC and refrigeration monitoring
- Food processing and storage temperature control
- Energy and power plant instrumentation
- Data acquisition systems requiring isolated thermocouple inputs
Compatibility:
- Compatible with all standard 5B backplanes and carriers (e.g., 5B01, 5B02, 5B08, 5B03A).
- Output can be connected directly to analog input channels of DAQ cards, PLCs, or control systems expecting 0–5 V input.
- Works with standard Type T thermocouples (Copper-Constantan) with miniature or standard connectors.
5. Components & Accessories
Included Items:
- 1 × 5B47-T07 Thermocouple Input Module
- Integrated cold-junction compensation sensor
- Internal filtering and isolation circuitry
- Factory calibration for 0–200°C range
Optional Accessories:
- 5B Series backplanes (e.g., 5B01 single-channel, 5B08 eight-channel)
- DIN-rail mounting carriers
- Thermocouple input connectors and terminal blocks
- Shielded cables for noise reduction
- Calibration and test adapters
Connectors:
- Input: Screw terminals or plug-in connector for thermocouple leads
- Output: Standard 5B backplane connector providing 0–5 V output and power interface
6. Installation & Setup
Requirements:
- Compatible 5B backplane or carrier with +5 V DC supply
- Type T thermocouple sensor
- Analog input device capable of reading 0–5 V signals
Mounting Options:
- Plug directly into a 5B backplane socket
- Mount on DIN-rail using a 5B carrier
- Ensure adequate ventilation and avoid exposure to excessive vibration or moisture
Configuration Steps:
1. Insert the module into the appropriate 5B backplane slot.
2. Connect the Type T thermocouple leads to the input terminals (observe polarity).
3. Connect the backplane output to the analog input of the data acquisition or control system.
4. Power the backplane with +5 V DC.
5. Verify output scaling: 0°C should correspond to 0 V, and +200°C to +5 V.
6. Perform system calibration if required for critical applications.
Safety Considerations:
- Ensure isolation barriers are not bypassed.
- Use shielded cables for thermocouple connections in noisy environments.
- Avoid connecting non-isolated sensors directly to high-voltage systems.
7. Performance & Capabilities
The 5B47-T07 delivers high accuracy and stability for low-temperature thermocouple measurements. Its internal linearization and cold-junction compensation ensure precise readings across the full 0–200°C range. The module’s isolation barrier effectively eliminates ground loops and common-mode noise, making it ideal for multi-channel systems with mixed signal sources.
Performance Highlights:
- Accuracy: ±0.1% of full scale ensures reliable temperature readings.
- Noise Rejection: High CMRR (>120 dB) and internal filtering minimize interference.
- Response Time: <100 ms allows near real-time monitoring.
- Thermal Stability: Low drift over temperature ensures consistent performance.
- Output Drive Capability: Can drive standard analog inputs with minimal loading effect.
- Efficiency: Low power consumption supports dense multi-channel installations.
Limitations:
- Fixed input range (0–200°C) — not suitable for higher temperature Type T applications without recalibration.
- Output limited to 0–5 V — may require scaling for systems expecting different voltage ranges.
- Bandwidth limited to a few hertz — optimized for steady-state temperature monitoring rather than fast transient detection.
8. Standards & Compliance
The 5B47-T07 and the broader 5B Series are designed to meet or exceed relevant industrial and safety standards for signal conditioning modules.
Certifications and Compliance:
- CE Marked: Conforms to European EMC and Low Voltage Directives.
- RoHS Compliant: Free from hazardous substances as per EU Directive 2011/65/EU.
- UL Recognized Components: Housing materials and design meet UL94V-0 flammability standards.
- EMC Compliance: Designed to meet EN 61326-1 (Industrial Environment) for electromagnetic compatibility.
- Safety Isolation: Meets IEC 61010-1 requirements for measurement, control, and laboratory equipment.
Industry Standards:
- Compatible with IEEE and ISA signal conditioning conventions.
- Designed for integration with standard 5B backplanes and data acquisition systems following the 5B module interface specification.
9. Additional Information
Warranty:
Typically supplied with a 1-year limited warranty covering defects in materials and workmanship under normal operating conditions. Extended warranties may be available depending on the distributor or manufacturer.
Support:
- Technical documentation, datasheets, and application notes available from the manufacturer’s website.
- Calibration and configuration support provided through authorized service centers.
- Online resources include wiring diagrams, installation guides, and compatibility charts for 5B modules.
Maintenance:
- Virtually maintenance-free; no moving parts.
- Periodic calibration verification recommended for critical measurement systems.
- Inspect connectors and terminals periodically for corrosion or loose connections.
Firmware/Updates:
- The 5B47-T07 is an analog hardware module with no firmware; updates pertain to calibration procedures or accessory compatibility.
Service Life:
- Designed for long-term operation in industrial environments, with typical service life exceeding 10 years under normal conditions.
Environmental Considerations:
- Fully encapsulated electronics for protection against dust and humidity.
- Compliant with environmental directives for electronic waste (WEEE).
- Low power consumption contributes to energy-efficient system design.
### Summary
The 5B47-T07 Thermocouple Input Module is a high-precision, isolated signal conditioning device engineered for accurate measurement of Type T thermocouple signals over a 0°C to +200°C range. Delivering a linearized 0–5 V output, it integrates seamlessly into 5B Series backplanes and data acquisition systems. With built-in cold-junction compensation, galvanic isolation, and robust filtering, the module ensures reliable, noise-free temperature measurement in demanding industrial and laboratory environments. Its compact design, standardized interface, and proven 5B architecture make it a dependable choice for engineers and system integrators seeking precision, safety, and ease of integration in temperature monitoring applications.
Name: 5B47-T07 Thermocouple Input Module
Model: 5B47-T07
Series: 5B Series Analog Signal Conditioning Modules
Article Number: 5B47-T07
Manufacturer: (Typically produced by Analog Devices or compatible 5B module manufacturers; part of the 5B signal conditioning family widely used in industrial and laboratory data acquisition systems.)
The 5B47-T07 is a precision thermocouple input module designed for direct connection to Type T thermocouples. It provides a linearized, isolated, and amplified analog output signal of 0–5 V, corresponding to an input temperature range of 0°C to +200°C. The module belongs to the 5B Series, a family of compact, plug-in signal conditioning modules used for accurate, isolated measurement of various sensor types in industrial, laboratory, and process control environments.
2. Key Features
- Thermocouple Input (Type T): Accepts direct connection from Type T thermocouples (Copper-Constantan).
- Input Range: 0°C to +200°C, optimized for low-temperature measurement applications.
- Output Signal: Linearized 0–5 V DC analog output, directly proportional to the measured temperature.
- Linearization: Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion.
- Galvanic Isolation: Provides high-level isolation between input, output, and power supply, typically rated at 1500 V rms or higher, protecting downstream equipment and reducing ground loop interference.
- High Accuracy and Stability: Designed for precision measurement with low drift and high common-mode rejection ratio (CMRR).
- Compact 5B Form Factor: Standardized plug-in module compatible with 5B backplanes and carriers.
- Ease of Integration: Standard 0–5 V output allows direct interface with analog input channels of data acquisition systems, PLCs, and control systems.
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance over extended temperature ranges.
- Low Power Consumption: Optimized for multi-channel systems with minimal heat generation.
- Plug-and-Play Compatibility: Works with standard 5B backplanes, simplifying installation and replacement.
3. Technical Specifications
*(Typical values for 5B47-T07 module; actual performance may vary slightly depending on manufacturer and configuration.)*
- Input Type: Thermocouple Type T (Copper-Constantan)
- Input Range: 0°C to +200°C
- Output Range: 0 V to +5 V DC (linearized)
- Transfer Function: 0°C → 0 V; +200°C → +5 V
- Accuracy: ±0.1% of full scale (typical)
- Linearity Error: ±0.05% of full scale (typical)
- Cold Junction Compensation: Internal, automatic
- Isolation Voltage: 1500 V rms (input-to-output and input-to-power)
- Common Mode Rejection Ratio (CMRR): >120 dB at 50/60 Hz
- Input Impedance: >10 MΩ
- Output Impedance: <1 Ω
- Bandwidth: DC to 3 Hz (typical, limited for noise reduction)
- Response Time: <100 ms to 90% of final value
- Power Supply Voltage: +5 V DC ±5% (supplied via 5B backplane)
- Power Consumption: Typically 25–35 mW per module
- Operating Temperature Range: –40°C to +85°C
- Storage Temperature Range: –40°C to +85°C
- Relative Humidity: 0–95%, non-condensing
- Dimensions: Approx. 60 mm (L) × 15 mm (W) × 25 mm (H) (standard 5B module size)
- Weight: Approximately 25–30 g
- Material: Molded thermoplastic housing, flame-retardant, UL94V-0 rated
- Mounting: Plug-in module for 5B backplane or DIN-rail carrier
4. Functionality
The 5B47-T07 operates as a precision signal conditioning interface between a Type T thermocouple sensor and a data acquisition or control system. The thermocouple generates a small voltage proportional to the temperature difference between its measuring junction and reference junction. The module performs several key functions:
1. Signal Amplification: The low-level thermocouple voltage (in microvolts per degree Celsius) is amplified to a standard 0–5 V output range suitable for most analog input devices.
2. Cold Junction Compensation (CJC): The module includes an internal temperature sensor that measures the ambient temperature at the input terminals, automatically compensating for the reference junction temperature.
3. Linearization: The nonlinear thermocouple response is electronically linearized to produce a direct, proportional voltage output corresponding to temperature.
4. Isolation: The module provides galvanic isolation between the thermocouple input, output signal, and power supply, preventing ground loops and ensuring measurement integrity.
5. Filtering: Internal low-pass filtering minimizes noise and interference from industrial environments.
Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement systems
- Environmental test chambers
- HVAC and refrigeration monitoring
- Food processing and storage temperature control
- Energy and power plant instrumentation
- Data acquisition systems requiring isolated thermocouple inputs
Compatibility:
- Compatible with all standard 5B backplanes and carriers (e.g., 5B01, 5B02, 5B08, 5B03A).
- Output can be connected directly to analog input channels of DAQ cards, PLCs, or control systems expecting 0–5 V input.
- Works with standard Type T thermocouples (Copper-Constantan) with miniature or standard connectors.
5. Components & Accessories
Included Items:
- 1 × 5B47-T07 Thermocouple Input Module
- Integrated cold-junction compensation sensor
- Internal filtering and isolation circuitry
- Factory calibration for 0–200°C range
Optional Accessories:
- 5B Series backplanes (e.g., 5B01 single-channel, 5B08 eight-channel)
- DIN-rail mounting carriers
- Thermocouple input connectors and terminal blocks
- Shielded cables for noise reduction
- Calibration and test adapters
Connectors:
- Input: Screw terminals or plug-in connector for thermocouple leads
- Output: Standard 5B backplane connector providing 0–5 V output and power interface
6. Installation & Setup
Requirements:
- Compatible 5B backplane or carrier with +5 V DC supply
- Type T thermocouple sensor
- Analog input device capable of reading 0–5 V signals
Mounting Options:
- Plug directly into a 5B backplane socket
- Mount on DIN-rail using a 5B carrier
- Ensure adequate ventilation and avoid exposure to excessive vibration or moisture
Configuration Steps:
1. Insert the module into the appropriate 5B backplane slot.
2. Connect the Type T thermocouple leads to the input terminals (observe polarity).
3. Connect the backplane output to the analog input of the data acquisition or control system.
4. Power the backplane with +5 V DC.
5. Verify output scaling: 0°C should correspond to 0 V, and +200°C to +5 V.
6. Perform system calibration if required for critical applications.
Safety Considerations:
- Ensure isolation barriers are not bypassed.
- Use shielded cables for thermocouple connections in noisy environments.
- Avoid connecting non-isolated sensors directly to high-voltage systems.
7. Performance & Capabilities
The 5B47-T07 delivers high accuracy and stability for low-temperature thermocouple measurements. Its internal linearization and cold-junction compensation ensure precise readings across the full 0–200°C range. The module’s isolation barrier effectively eliminates ground loops and common-mode noise, making it ideal for multi-channel systems with mixed signal sources.
Performance Highlights:
- Accuracy: ±0.1% of full scale ensures reliable temperature readings.
- Noise Rejection: High CMRR (>120 dB) and internal filtering minimize interference.
- Response Time: <100 ms allows near real-time monitoring.
- Thermal Stability: Low drift over temperature ensures consistent performance.
- Output Drive Capability: Can drive standard analog inputs with minimal loading effect.
- Efficiency: Low power consumption supports dense multi-channel installations.
Limitations:
- Fixed input range (0–200°C) — not suitable for higher temperature Type T applications without recalibration.
- Output limited to 0–5 V — may require scaling for systems expecting different voltage ranges.
- Bandwidth limited to a few hertz — optimized for steady-state temperature monitoring rather than fast transient detection.
8. Standards & Compliance
The 5B47-T07 and the broader 5B Series are designed to meet or exceed relevant industrial and safety standards for signal conditioning modules.
Certifications and Compliance:
- CE Marked: Conforms to European EMC and Low Voltage Directives.
- RoHS Compliant: Free from hazardous substances as per EU Directive 2011/65/EU.
- UL Recognized Components: Housing materials and design meet UL94V-0 flammability standards.
- EMC Compliance: Designed to meet EN 61326-1 (Industrial Environment) for electromagnetic compatibility.
- Safety Isolation: Meets IEC 61010-1 requirements for measurement, control, and laboratory equipment.
Industry Standards:
- Compatible with IEEE and ISA signal conditioning conventions.
- Designed for integration with standard 5B backplanes and data acquisition systems following the 5B module interface specification.
9. Additional Information
Warranty:
Typically supplied with a 1-year limited warranty covering defects in materials and workmanship under normal operating conditions. Extended warranties may be available depending on the distributor or manufacturer.
Support:
- Technical documentation, datasheets, and application notes available from the manufacturer’s website.
- Calibration and configuration support provided through authorized service centers.
- Online resources include wiring diagrams, installation guides, and compatibility charts for 5B modules.
Maintenance:
- Virtually maintenance-free; no moving parts.
- Periodic calibration verification recommended for critical measurement systems.
- Inspect connectors and terminals periodically for corrosion or loose connections.
Firmware/Updates:
- The 5B47-T07 is an analog hardware module with no firmware; updates pertain to calibration procedures or accessory compatibility.
Service Life:
- Designed for long-term operation in industrial environments, with typical service life exceeding 10 years under normal conditions.
Environmental Considerations:
- Fully encapsulated electronics for protection against dust and humidity.
- Compliant with environmental directives for electronic waste (WEEE).
- Low power consumption contributes to energy-efficient system design.
### Summary
The 5B47-T07 Thermocouple Input Module is a high-precision, isolated signal conditioning device engineered for accurate measurement of Type T thermocouple signals over a 0°C to +200°C range. Delivering a linearized 0–5 V output, it integrates seamlessly into 5B Series backplanes and data acquisition systems. With built-in cold-junction compensation, galvanic isolation, and robust filtering, the module ensures reliable, noise-free temperature measurement in demanding industrial and laboratory environments. Its compact design, standardized interface, and proven 5B architecture make it a dependable choice for engineers and system integrators seeking precision, safety, and ease of integration in temperature monitoring applications.
No manuals/catalogs available.
No accessories available.