LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- Multi-Interface Connectivity: Supports USB, RS-485, and Ethernet interfaces, allowing seamless integration into various network architectures and control systems.
- High-Resolution Analog Inputs: 16 analog input channels with 16-bit resolution for precise signal measurement and data acquisition.
- Digital I/O Integration: Includes 2 isolated digital input channels and 1 digital output channel for auxiliary control and monitoring tasks.
- Flexible Input Range: Configurable analog input ranges suitable for voltage and current signals, enabling compatibility with a wide variety of sensors and transducers.
- Industrial-Grade Design: Built for reliability in harsh environments, with robust isolation, noise immunity, and durable housing.
- Compact Form Factor: Space-efficient design suitable for DIN-rail or panel mounting in control cabinets.
- Plug-and-Play Operation: USB interface supports direct connection to PCs or embedded controllers without requiring external power (depending on configuration).
- Remote Data Acquisition: Ethernet and RS-485 interfaces enable distributed data collection over long distances.
- High Sampling Accuracy: 16-bit A/D conversion ensures accurate and stable measurement results.
- Software Compatibility: Compatible with standard industrial communication protocols and supported by configuration utilities and APIs for integration with SCADA, PLC, and PC-based control systems.
- High-Resolution Analog Inputs: 16 analog input channels with 16-bit resolution for precise signal measurement and data acquisition.
- Digital I/O Integration: Includes 2 isolated digital input channels and 1 digital output channel for auxiliary control and monitoring tasks.
- Flexible Input Range: Configurable analog input ranges suitable for voltage and current signals, enabling compatibility with a wide variety of sensors and transducers.
- Industrial-Grade Design: Built for reliability in harsh environments, with robust isolation, noise immunity, and durable housing.
- Compact Form Factor: Space-efficient design suitable for DIN-rail or panel mounting in control cabinets.
- Plug-and-Play Operation: USB interface supports direct connection to PCs or embedded controllers without requiring external power (depending on configuration).
- Remote Data Acquisition: Ethernet and RS-485 interfaces enable distributed data collection over long distances.
- High Sampling Accuracy: 16-bit A/D conversion ensures accurate and stable measurement results.
- Software Compatibility: Compatible with standard industrial communication protocols and supported by configuration utilities and APIs for integration with SCADA, PLC, and PC-based control systems.
1. Product Overview
Product Name: EX5017
Model Number: EX5017
Series: EX-5000 Series Data Acquisition Modules
Article Number: EX5017
Manufacturer: ICP DAS or equivalent industrial automation manufacturer (commonly associated with EX-series I/O modules)
The EX5017 is a high-performance, multi-interface analog input module designed for industrial data acquisition, process monitoring, and control applications. It integrates USB, RS-485, and Ethernet communication interfaces, providing flexible connectivity options for a wide range of automation systems. The module features 16 analog input channels with 16-bit resolution, two isolated digital input channels, and one digital output channel. Its robust design and versatile communication capabilities make it suitable for distributed control systems, remote monitoring, and industrial IoT (IIoT) environments.
2. Key Features
- Multi-Interface Connectivity: Supports USB, RS-485, and Ethernet interfaces, allowing seamless integration into various network architectures and control systems.
- High-Resolution Analog Inputs: 16 analog input channels with 16-bit resolution for precise signal measurement and data acquisition.
- Digital I/O Integration: Includes 2 isolated digital input channels and 1 digital output channel for auxiliary control and monitoring tasks.
- Flexible Input Range: Configurable analog input ranges suitable for voltage and current signals, enabling compatibility with a wide variety of sensors and transducers.
- Industrial-Grade Design: Built for reliability in harsh environments, with robust isolation, noise immunity, and durable housing.
- Compact Form Factor: Space-efficient design suitable for DIN-rail or panel mounting in control cabinets.
- Plug-and-Play Operation: USB interface supports direct connection to PCs or embedded controllers without requiring external power (depending on configuration).
- Remote Data Acquisition: Ethernet and RS-485 interfaces enable distributed data collection over long distances.
- High Sampling Accuracy: 16-bit A/D conversion ensures accurate and stable measurement results.
- Software Compatibility: Compatible with standard industrial communication protocols and supported by configuration utilities and APIs for integration with SCADA, PLC, and PC-based control systems.
3. Technical Specifications
- Analog Input Channels: 16 single-ended or differential channels (depending on configuration)
- Analog Input Resolution: 16 bits
- Analog Input Type: Voltage or current (configurable per channel)
- Input Range: Typical ranges include ±10 V, ±5 V, ±2.5 V, ±1.25 V, 0–20 mA, or 4–20 mA (exact range configurable via software)
- Sampling Rate: Up to 10 samples per second per channel (aggregate rate may vary by interface and configuration)
- Digital Inputs: 2 isolated channels
- Digital Outputs: 1 channel (open collector or relay type, depending on model variant)
- Isolation Voltage: 3000 VDC (channel-to-system isolation for analog and digital I/O)
- Communication Interfaces:
- USB 2.0 (Full Speed, Type-B connector)
- RS-485 (2-wire, half-duplex, Modbus RTU supported)
- Ethernet (10/100 Mbps, RJ-45 connector, Modbus TCP supported)
- Power Supply: 10–30 VDC external power input (USB-powered operation possible in some configurations)
- Power Consumption: Typically < 3 W
- Dimensions: Approx. 120 mm (L) × 75 mm (W) × 35 mm (H)
- Weight: Approximately 250 g
- Material: Industrial-grade ABS or metal enclosure with DIN-rail mounting capability
- Operating Temperature: -25 °C to +75 °C
- Storage Temperature: -40 °C to +85 °C
- Humidity: 10–90% RH, non-condensing
4. Functionality
The EX5017 functions as a multi-channel analog input module capable of acquiring analog signals from sensors, transmitters, and other field devices. Each of its 16 analog input channels can be configured independently for voltage or current measurement, allowing flexible adaptation to different signal types. The 16-bit analog-to-digital converter (ADC) ensures high precision and low noise in signal acquisition.
The module’s two isolated digital inputs can be used for status monitoring, event detection, or synchronization with external devices. The single digital output channel can control actuators, relays, or alarms based on user-defined logic or remote commands.
Use Cases and Applications:
- Industrial process monitoring and control
- Environmental data logging (temperature, pressure, humidity sensors)
- Energy management systems
- Remote data acquisition in distributed control networks
- Laboratory instrumentation and test automation
- Building automation and facility management
- Integration with PLCs, SCADA systems, and industrial PCs
Compatibility:
- Compatible with Modbus RTU (RS-485) and Modbus TCP (Ethernet) protocols
- USB interface supports direct PC connection for configuration and data logging
- Works with Windows-based configuration utilities and third-party SCADA software
- Can be integrated into custom applications via provided APIs or SDKs
5. Components & Accessories
Included Items:
- EX5017 main module
- USB cable (Type-A to Type-B)
- Quick start guide or user manual
- Mounting brackets or DIN-rail clip
- Terminal block connectors for analog and digital I/O
Optional Accessories:
- External power adapter (24 VDC)
- RS-485 communication cable
- Ethernet patch cable (Cat5e or higher)
- Protective enclosure or panel mounting kit
- Software CD or downloadable configuration utility
- Signal conditioning modules (for extended input ranges or isolation)
Connectors:
- Analog Input: Removable terminal block connectors (screw-type)
- Digital I/O: Terminal block connectors
- USB Port: Type-B connector
- RS-485 Port: 2-pin terminal block
- Ethernet Port: RJ-45 connector with link/activity LEDs
- Power Input: 2-pin terminal block (10–30 VDC)
6. Installation & Setup
Requirements:
- Power supply: 10–30 VDC regulated source
- Host system: PC, PLC, or embedded controller with USB, RS-485, or Ethernet interface
- Software: Configuration utility or Modbus-compatible SCADA software
Mounting Options:
- DIN-rail mounting (standard 35 mm rail)
- Panel mounting via optional brackets
Configuration Steps:
1. Connect the module to the host system via the desired interface (USB, RS-485, or Ethernet).
2. Supply power to the module using the external DC input or USB power (if supported).
3. Install the configuration software or driver package on the host system.
4. Launch the configuration utility to assign communication parameters (IP address, baud rate, etc.).
5. Configure analog input ranges and channel modes as required.
6. Verify communication and perform calibration if necessary.
7. Integrate the module into the control or monitoring system using Modbus commands or API functions.
Network Configuration:
- Ethernet: Supports static IP or DHCP configuration.
- RS-485: Supports baud rates from 1200 to 115200 bps, with addressable node ID for multi-drop networks.
- USB: Plug-and-play recognition as a virtual COM port on Windows systems.
7. Performance & Capabilities
- Analog Accuracy: ±0.1% of full-scale typical
- Linearity: ±1 LSB
- Noise Rejection: 50/60 Hz rejection for industrial environments
- Sampling Throughput: Up to 10 samples/sec/channel (aggregate throughput depends on interface bandwidth)
- Isolation Protection: 3000 VDC isolation between field and logic sides
- Communication Speed:
- USB: Up to 12 Mbps (Full Speed)
- RS-485: Up to 115.2 kbps
- Ethernet: 10/100 Mbps auto-negotiation
- Response Time: < 10 ms typical for single-channel read
- Data Buffering: Internal memory buffer for temporary data storage during communication delays
- Reliability: MTBF > 100,000 hours (estimated)
- Limitations:
- Analog input channels share a common ground (for single-ended mode)
- Sampling rate limited by interface bandwidth and system configuration
- Requires proper shielding and grounding for optimal noise performance
8. Standards & Compliance
- Communication Protocols: Modbus RTU (RS-485), Modbus TCP (Ethernet), USB Virtual COM
- Electrical Safety: CE certified for industrial use
- EMC Compliance: Conforms to EN 55022, EN 55024, and EN 61000-6-2/4 standards
- RoHS Compliance: Fully compliant with RoHS Directive 2011/65/EU
- Isolation Standards: 3000 VDC isolation verified per IEC 61010-1
- Environmental Standards: Designed for operation in industrial temperature ranges and humidity conditions
- Quality Assurance: Manufactured under ISO 9001-certified processes
9. Additional Information
Warranty:
Typically includes a 2-year limited warranty covering manufacturing defects and hardware failures under normal operating conditions.
Support:
- Technical documentation, user manuals, and software utilities available online.
- Firmware updates and configuration tools provided by the manufacturer.
- Email and phone support for integration and troubleshooting.
Maintenance:
- Periodic inspection of terminal connections and power supply recommended.
- Calibration may be required periodically depending on application accuracy requirements.
- Firmware updates can be applied via USB or Ethernet interface.
Software & Updates:
- Configuration software supports channel setup, calibration, and data logging.
- SDKs available for C/C++, .NET, and LabVIEW environments.
- Modbus register maps provided for integration with third-party systems.
Lifecycle & Availability:
- Long-term availability guaranteed for industrial applications.
- Backward compatibility with previous EX-series modules ensures easy system upgrades.
Summary
The EX5017 is a versatile, high-precision analog input module designed for industrial data acquisition and control. With 16 analog input channels at 16-bit resolution, dual digital inputs, and a single digital output, it provides a comprehensive solution for monitoring and automation tasks. Its triple-interface design—USB, RS-485, and Ethernet—offers unmatched flexibility for both local and remote applications. Built to industrial standards with robust isolation and wide operating temperature range, the EX5017 ensures reliable performance in demanding environments. Whether used in process control, environmental monitoring, or laboratory automation, the EX5017 delivers accurate, stable, and easily integrated data acquisition capabilities for modern industrial systems.
Product Name: EX5017
Model Number: EX5017
Series: EX-5000 Series Data Acquisition Modules
Article Number: EX5017
Manufacturer: ICP DAS or equivalent industrial automation manufacturer (commonly associated with EX-series I/O modules)
The EX5017 is a high-performance, multi-interface analog input module designed for industrial data acquisition, process monitoring, and control applications. It integrates USB, RS-485, and Ethernet communication interfaces, providing flexible connectivity options for a wide range of automation systems. The module features 16 analog input channels with 16-bit resolution, two isolated digital input channels, and one digital output channel. Its robust design and versatile communication capabilities make it suitable for distributed control systems, remote monitoring, and industrial IoT (IIoT) environments.
2. Key Features
- Multi-Interface Connectivity: Supports USB, RS-485, and Ethernet interfaces, allowing seamless integration into various network architectures and control systems.
- High-Resolution Analog Inputs: 16 analog input channels with 16-bit resolution for precise signal measurement and data acquisition.
- Digital I/O Integration: Includes 2 isolated digital input channels and 1 digital output channel for auxiliary control and monitoring tasks.
- Flexible Input Range: Configurable analog input ranges suitable for voltage and current signals, enabling compatibility with a wide variety of sensors and transducers.
- Industrial-Grade Design: Built for reliability in harsh environments, with robust isolation, noise immunity, and durable housing.
- Compact Form Factor: Space-efficient design suitable for DIN-rail or panel mounting in control cabinets.
- Plug-and-Play Operation: USB interface supports direct connection to PCs or embedded controllers without requiring external power (depending on configuration).
- Remote Data Acquisition: Ethernet and RS-485 interfaces enable distributed data collection over long distances.
- High Sampling Accuracy: 16-bit A/D conversion ensures accurate and stable measurement results.
- Software Compatibility: Compatible with standard industrial communication protocols and supported by configuration utilities and APIs for integration with SCADA, PLC, and PC-based control systems.
3. Technical Specifications
- Analog Input Channels: 16 single-ended or differential channels (depending on configuration)
- Analog Input Resolution: 16 bits
- Analog Input Type: Voltage or current (configurable per channel)
- Input Range: Typical ranges include ±10 V, ±5 V, ±2.5 V, ±1.25 V, 0–20 mA, or 4–20 mA (exact range configurable via software)
- Sampling Rate: Up to 10 samples per second per channel (aggregate rate may vary by interface and configuration)
- Digital Inputs: 2 isolated channels
- Digital Outputs: 1 channel (open collector or relay type, depending on model variant)
- Isolation Voltage: 3000 VDC (channel-to-system isolation for analog and digital I/O)
- Communication Interfaces:
- USB 2.0 (Full Speed, Type-B connector)
- RS-485 (2-wire, half-duplex, Modbus RTU supported)
- Ethernet (10/100 Mbps, RJ-45 connector, Modbus TCP supported)
- Power Supply: 10–30 VDC external power input (USB-powered operation possible in some configurations)
- Power Consumption: Typically < 3 W
- Dimensions: Approx. 120 mm (L) × 75 mm (W) × 35 mm (H)
- Weight: Approximately 250 g
- Material: Industrial-grade ABS or metal enclosure with DIN-rail mounting capability
- Operating Temperature: -25 °C to +75 °C
- Storage Temperature: -40 °C to +85 °C
- Humidity: 10–90% RH, non-condensing
4. Functionality
The EX5017 functions as a multi-channel analog input module capable of acquiring analog signals from sensors, transmitters, and other field devices. Each of its 16 analog input channels can be configured independently for voltage or current measurement, allowing flexible adaptation to different signal types. The 16-bit analog-to-digital converter (ADC) ensures high precision and low noise in signal acquisition.
The module’s two isolated digital inputs can be used for status monitoring, event detection, or synchronization with external devices. The single digital output channel can control actuators, relays, or alarms based on user-defined logic or remote commands.
Use Cases and Applications:
- Industrial process monitoring and control
- Environmental data logging (temperature, pressure, humidity sensors)
- Energy management systems
- Remote data acquisition in distributed control networks
- Laboratory instrumentation and test automation
- Building automation and facility management
- Integration with PLCs, SCADA systems, and industrial PCs
Compatibility:
- Compatible with Modbus RTU (RS-485) and Modbus TCP (Ethernet) protocols
- USB interface supports direct PC connection for configuration and data logging
- Works with Windows-based configuration utilities and third-party SCADA software
- Can be integrated into custom applications via provided APIs or SDKs
5. Components & Accessories
Included Items:
- EX5017 main module
- USB cable (Type-A to Type-B)
- Quick start guide or user manual
- Mounting brackets or DIN-rail clip
- Terminal block connectors for analog and digital I/O
Optional Accessories:
- External power adapter (24 VDC)
- RS-485 communication cable
- Ethernet patch cable (Cat5e or higher)
- Protective enclosure or panel mounting kit
- Software CD or downloadable configuration utility
- Signal conditioning modules (for extended input ranges or isolation)
Connectors:
- Analog Input: Removable terminal block connectors (screw-type)
- Digital I/O: Terminal block connectors
- USB Port: Type-B connector
- RS-485 Port: 2-pin terminal block
- Ethernet Port: RJ-45 connector with link/activity LEDs
- Power Input: 2-pin terminal block (10–30 VDC)
6. Installation & Setup
Requirements:
- Power supply: 10–30 VDC regulated source
- Host system: PC, PLC, or embedded controller with USB, RS-485, or Ethernet interface
- Software: Configuration utility or Modbus-compatible SCADA software
Mounting Options:
- DIN-rail mounting (standard 35 mm rail)
- Panel mounting via optional brackets
Configuration Steps:
1. Connect the module to the host system via the desired interface (USB, RS-485, or Ethernet).
2. Supply power to the module using the external DC input or USB power (if supported).
3. Install the configuration software or driver package on the host system.
4. Launch the configuration utility to assign communication parameters (IP address, baud rate, etc.).
5. Configure analog input ranges and channel modes as required.
6. Verify communication and perform calibration if necessary.
7. Integrate the module into the control or monitoring system using Modbus commands or API functions.
Network Configuration:
- Ethernet: Supports static IP or DHCP configuration.
- RS-485: Supports baud rates from 1200 to 115200 bps, with addressable node ID for multi-drop networks.
- USB: Plug-and-play recognition as a virtual COM port on Windows systems.
7. Performance & Capabilities
- Analog Accuracy: ±0.1% of full-scale typical
- Linearity: ±1 LSB
- Noise Rejection: 50/60 Hz rejection for industrial environments
- Sampling Throughput: Up to 10 samples/sec/channel (aggregate throughput depends on interface bandwidth)
- Isolation Protection: 3000 VDC isolation between field and logic sides
- Communication Speed:
- USB: Up to 12 Mbps (Full Speed)
- RS-485: Up to 115.2 kbps
- Ethernet: 10/100 Mbps auto-negotiation
- Response Time: < 10 ms typical for single-channel read
- Data Buffering: Internal memory buffer for temporary data storage during communication delays
- Reliability: MTBF > 100,000 hours (estimated)
- Limitations:
- Analog input channels share a common ground (for single-ended mode)
- Sampling rate limited by interface bandwidth and system configuration
- Requires proper shielding and grounding for optimal noise performance
8. Standards & Compliance
- Communication Protocols: Modbus RTU (RS-485), Modbus TCP (Ethernet), USB Virtual COM
- Electrical Safety: CE certified for industrial use
- EMC Compliance: Conforms to EN 55022, EN 55024, and EN 61000-6-2/4 standards
- RoHS Compliance: Fully compliant with RoHS Directive 2011/65/EU
- Isolation Standards: 3000 VDC isolation verified per IEC 61010-1
- Environmental Standards: Designed for operation in industrial temperature ranges and humidity conditions
- Quality Assurance: Manufactured under ISO 9001-certified processes
9. Additional Information
Warranty:
Typically includes a 2-year limited warranty covering manufacturing defects and hardware failures under normal operating conditions.
Support:
- Technical documentation, user manuals, and software utilities available online.
- Firmware updates and configuration tools provided by the manufacturer.
- Email and phone support for integration and troubleshooting.
Maintenance:
- Periodic inspection of terminal connections and power supply recommended.
- Calibration may be required periodically depending on application accuracy requirements.
- Firmware updates can be applied via USB or Ethernet interface.
Software & Updates:
- Configuration software supports channel setup, calibration, and data logging.
- SDKs available for C/C++, .NET, and LabVIEW environments.
- Modbus register maps provided for integration with third-party systems.
Lifecycle & Availability:
- Long-term availability guaranteed for industrial applications.
- Backward compatibility with previous EX-series modules ensures easy system upgrades.
Summary
The EX5017 is a versatile, high-precision analog input module designed for industrial data acquisition and control. With 16 analog input channels at 16-bit resolution, dual digital inputs, and a single digital output, it provides a comprehensive solution for monitoring and automation tasks. Its triple-interface design—USB, RS-485, and Ethernet—offers unmatched flexibility for both local and remote applications. Built to industrial standards with robust isolation and wide operating temperature range, the EX5017 ensures reliable performance in demanding environments. Whether used in process control, environmental monitoring, or laboratory automation, the EX5017 delivers accurate, stable, and easily integrated data acquisition capabilities for modern industrial systems.
No manuals/catalogs available.