LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

PCIS-LView/2000/NT/98/95

LabView driver for ADLink PCI Cards
- Purpose‑Built LabVIEW Integration:
PCIS‑LView provides a seamless interface between National Instruments LabVIEW (v4.0 or later) and ADLINK’s NuDAQ PCI and NuIPC CompactPCI DAQ hardware. It enables direct access to ADLINK’s PCIS‑DASK driver functions through LabVIEW virtual instruments (VIs).

- Cross‑Platform Driver Support:
Compatible with multiple Microsoft Windows operating systems—Windows 95, 98, NT 4.0, and 2000—ensuring broad deployment flexibility in legacy and industrial environments.

- Comprehensive Hardware Coverage:
Supports a wide range of ADLINK PCI and CompactPCI DAQ cards, including analog input/output, digital I/O, counter/timer, and multifunction boards (e.g., PCI‑6208, PCI‑7200, PCI‑7230, PCI‑9112, PCI‑9812, etc.).

- Plug‑and‑Play Hardware Detection:
Fully utilizes Windows Plug and Play for automatic device recognition and resource allocation (I/O ports, IRQs).

- Integrated Configuration Utility:
Includes the NuDAQ PCI Configuration Utility (PciUtil) for driver registration, buffer allocation, and continuous I/O memory management.

- Unified Software Architecture:
Works in conjunction with PCIS‑DASK (Dynamic‑Link Library driver) and PCIS‑VEE (HP VEE interface) to provide a consistent API across programming environments.

- Extensive Documentation and Examples:
Ships with PDF manuals, online help, and sample LabVIEW VIs for each supported card type.

- Backward Compatibility:
Maintains support for older LabVIEW versions (≥4.0) and legacy Windows systems, ensuring long‑term usability in industrial automation setups.

Country of origin: Taiwan R.O.C.

Comprehensive Product Summary: ADLINK PCIS‑LView/2000/NT/98/95 – LabVIEW Driver for ADLINK PCI and CompactPCI DAQ Cards




### 1. Product Overview

Product Name: PCIS‑LView/2000/NT/98/95
Article Number: PCIS‑LView/2000/NT/98/95
Series: NuDAQ PCI / NuIPC CompactPCI Software Drivers
Manufacturer: ADLINK Technology Inc.
Product Type: LabVIEW driver and integration library for ADLINK PCI‑bus and CompactPCI data acquisition (DAQ) cards
Manual Revision: Rev. 3.00 (June 25, 2000)
Copyright: © 1999–2000 ADLINK Technology Inc.

Manufacturer Contact Information:
ADLINK Technology Inc., 9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan, R.O.C.
Tel: +886‑2‑82265877 Fax: +886‑2‑82265717
Web: [www.adlink.com.tw](http://www.adlink.com.tw)
Email: service@adlink.com.tw (general), nudaq@adlink.com.tw (NuDAQ support), sw@adlink.com.tw (software support)




### 2. Key Features

- Purpose‑Built LabVIEW Integration:
PCIS‑LView provides a seamless interface between National Instruments LabVIEW (v4.0 or later) and ADLINK’s NuDAQ PCI and NuIPC CompactPCI DAQ hardware. It enables direct access to ADLINK’s PCIS‑DASK driver functions through LabVIEW virtual instruments (VIs).

- Cross‑Platform Driver Support:
Compatible with multiple Microsoft Windows operating systems—Windows 95, 98, NT 4.0, and 2000—ensuring broad deployment flexibility in legacy and industrial environments.

- Comprehensive Hardware Coverage:
Supports a wide range of ADLINK PCI and CompactPCI DAQ cards, including analog input/output, digital I/O, counter/timer, and multifunction boards (e.g., PCI‑6208, PCI‑7200, PCI‑7230, PCI‑9112, PCI‑9812, etc.).

- Plug‑and‑Play Hardware Detection:
Fully utilizes Windows Plug and Play for automatic device recognition and resource allocation (I/O ports, IRQs).

- Integrated Configuration Utility:
Includes the NuDAQ PCI Configuration Utility (PciUtil) for driver registration, buffer allocation, and continuous I/O memory management.

- Unified Software Architecture:
Works in conjunction with PCIS‑DASK (Dynamic‑Link Library driver) and PCIS‑VEE (HP VEE interface) to provide a consistent API across programming environments.

- Extensive Documentation and Examples:
Ships with PDF manuals, online help, and sample LabVIEW VIs for each supported card type.

- Backward Compatibility:
Maintains support for older LabVIEW versions (≥4.0) and legacy Windows systems, ensuring long‑term usability in industrial automation setups.




### 3. Technical Specifications

Supported Operating Systems:
- Windows 95, Windows 98, Windows NT 4.0, Windows 2000
- Linux (via PCIS‑DASK/X for kernel 2.2.x and later)

Supported Development Environments:
- National Instruments LabVIEW 4.0 or later
- Microsoft Visual C/C++, Visual Basic, Borland C++, Delphi (via PCIS‑DASK)
- HP VEE (via PCIS‑VEE)

Supported Hardware Families:
- NuDAQ PCI‑bus and NuIPC CompactPCI DAQ cards, including:
- Analog I/O: PCI‑6208A/V, PCI‑6308A/V, PCI‑9111/12/13/14/18, PCI‑9812
- Digital I/O: PCI‑7200, 7230, 7233, 7234, 7248, 7250, 7296, 7300A, 7396, 7432–7434
- Counter/Timer: PCI‑8554
- Multifunction: PCI‑911x, 9812 series

File Components:
- `Plv.llb` – LabVIEW VI library
- `Menus\adlink` – Custom LabVIEW menu integration
- `Util` – Configuration utilities
- `Manual` – PDF documentation
- `Help` – Online help files
- `Samples` – Example VIs for each card (e.g., 6208, 7200, 7230)

Memory Management:
- Configurable contiguous buffer allocation for continuous AI, AO, DI, DO operations (in KB units)
- Adjustable via PciUtil utility; supports DMA and interrupt‑driven transfers

Distribution Media:
ADLINK All‑in‑One CD (includes setup executables, INF files, DLLs, and manuals)




### 4. Functionality

Operational Overview:
PCIS‑LView acts as a LabVIEW interface layer to the PCIS‑DASK driver library. It exposes DAQ card functions as LabVIEW VIs, enabling graphical programming of analog and digital I/O, counter/timer operations, and trigger‑based data acquisition.

Use Cases:
- Industrial process monitoring and control
- Automated test and measurement systems
- Data logging and signal analysis
- Real‑time digital I/O control
- Analog waveform generation and acquisition

Compatibility:
- Fully compatible with ADLINK’s NuDAQ PCI and NuIPC CompactPCI hardware families
- Integrates with LabVIEW’s User.lib and menu system for direct access to ADLINK VIs
- Works alongside PCIS‑DASK DLLs for mixed‑language development

Applications:
- Continuous and one‑shot analog input/output
- Digital pattern generation and capture
- Counter/timer event measurement
- Triggered and buffered data acquisition
- DMA‑based high‑speed data streaming




### 5. Components & Accessories

Included Software Components:
- PCIS‑LView/2000/NT/98/95 installation package
- NuDAQ PCI Configuration Utility (PciUtil)
- PCIS‑DASK DLL libraries and import files
- INF and SYS device driver files for Windows Plug and Play
- Sample Programs: LabVIEW VIs for each supported card
- Documentation: PDF manuals, online help, and function references

Optional Add‑Ons:
- PCIS‑VEE – HP VEE driver package
- PCIS‑DASK/X – Linux driver package
- DAQBench – ADLINK’s graphical DAQ toolkit (optional)

Connectors and Interfaces:
- Standard PCI or CompactPCI bus interface
- Software‑level connection through LabVIEW VI libraries and DLL calls




### 6. Installation & Setup

System Requirements:
- IBM PC/AT compatible system
- Supported OS (Windows 95/98/NT/2000)
- CD‑ROM drive or floppy drive
- Installed LabVIEW (v4.0 or later)
- Available PCI slot with ADLINK DAQ card installed

Installation Procedure (Windows 98/2000 Example):
1. Insert the ADLINK All‑in‑One CD.
2. Run `X:\Setup.exe` (replace X with CD‑ROM drive letter).
3. Select Software Package → NuDAQ PCI Software → PCIS‑LVIEW → [OS Version].
4. The installer detects the LabVIEW directory and copies required files.
5. If LabVIEW is not found or is older than v5.0, specify the correct directory manually.
6. After installation, verify that `Plv.llb` and menu files are copied to `<LabVIEW Dir>\User.lib` and `<LabVIEW Dir>\Menus\adlink`.
7. Run PciUtil to configure buffer sizes and register drivers.
8. Restart the system to activate the drivers.

Uninstallation:
- Use Control Panel → Add/Remove Programs to remove PCIS‑LView or related ADLINK software.




### 7. Performance & Capabilities

Data Transfer Modes:
- Interrupt‑Driven and DMA (Direct Memory Access) transfers
- Single‑Buffered and Double‑Buffered continuous data streaming
- Trigger‑Based Acquisition: Supports pre‑trigger, post‑trigger, and about‑trigger modes

Buffer Management:
- Adjustable contiguous memory allocation for AI, AO, DI, DO
- Double‑buffered circular memory for continuous streaming without data loss
- Configurable via PciUtil utility (in KB increments)

Speed and Throughput:
- Dependent on card model (e.g., PCI‑9812 supports up to 20 MHz sampling)
- Supports high‑speed DMA transfers up to 40 MB/s (PCI‑7300A series)

Efficiency:
- Optimized for low CPU overhead through DMA and interrupt handling
- Supports asynchronous and synchronous operation modes

Limitations:
- Requires LabVIEW ≥ 4.0 and Windows 9x/NT/2000 environments
- Memory allocation limited by system resources and OS constraints
- Double‑buffered mode requires sufficient contiguous memory




### 8. Standards & Compliance

Certifications and Compliance:
- Designed for compliance with PCI Local Bus Specification
- Compatible with Microsoft Windows Hardware Driver Model (WDM)
- Supports Plug and Play and IRQ sharing under Windows 98/2000
- Follows ADLINK’s internal quality and reliability standards

Trademarks:
- NuDAQ®, NuIPC®, PCIS‑DASK®, and PCI series are registered trademarks of ADLINK Technology Inc.
- LabVIEW® is a registered trademark of National Instruments.
- HP VEE® is a registered trademark of Hewlett‑Packard.




### 9. Additional Information

Warranty & Support:
- Standard ADLINK limited warranty (coverage details per region)
- Technical support available via email and web resources
- Software updates and driver revisions periodically released on ADLINK’s website

Maintenance:
- Regularly update to the latest PCIS‑DASK and PCIS‑LView versions for new card support
- Use PciUtil to verify driver registration and buffer configuration after hardware changes
- Backup LabVIEW User.lib before upgrading

Documentation & Resources:
- User Guides: Installation and Function Reference Manuals (PDF)
- Online Help: Context‑sensitive LabVIEW help files
- Sample Programs: Demonstrate analog/digital I/O, DMA transfers, and trigger modes
- Troubleshooting Tools:
- `PCI_SCAN.EXE` (DOS utility) – lists BIOS PCI resource assignments
- `Ntfdpci.exe` (Windows NT utility) – logs driver and device status
- Diagnostic log files (`PCI_SCAN.LOG`, `NtPci.dat`) for support analysis

Common Troubleshooting Scenarios:
- Device not recognized: Verify INF installation and driver registry via Device Manager.
- Continuous operation failure: Increase buffer allocation using PciUtil.
- Unsuccessful installation: Ensure PCIS‑DASK is installed before connecting new cards.
- BIOS resource conflicts: Use PCI_SCAN utility to check IRQ and I/O assignments.

Software Update Policy:
- ADLINK periodically updates PCIS‑LView and PCIS‑DASK to support new NuDAQ and NuIPC cards.
- Updated drivers and manuals are available for download from ADLINK’s website.




### Summary

The ADLINK PCIS‑LView/2000/NT/98/95 package is a comprehensive LabVIEW driver suite designed to integrate ADLINK’s NuDAQ PCI and NuIPC CompactPCI data acquisition hardware into LabVIEW environments. It provides a robust, high‑performance interface for analog and digital I/O, counter/timer operations, and continuous data acquisition using DMA and interrupt mechanisms. With full support for Windows 95 through 2000, extensive sample programs, and a unified configuration utility, PCIS‑LView enables engineers and developers to rapidly build and deploy measurement and automation applications. Its modular architecture, compatibility with PCIS‑DASK and PCIS‑VEE, and detailed documentation make it a cornerstone of ADLINK’s DAQ software ecosystem.

No accessories available.