PXIS-3320/1000W

15-Slot 6U PXI/CompactPCI Chassis w 1000W AC
  • Manufacturer Adlink Technology Inc.
  • Category: PXIe PXI Chassis
  • The ADLINK PXIS‑3320/1000W is a high‑performance, 15‑slot, 6U PXI/CompactPCI chassis designed for modular instrumentation, data acquisition, and automated test applications. It integrates a robust 1000 W hot‑swappable AC power supply system, advanced thermal management, and full compliance with PXI Specification Rev. 2.2. The chassis supports both PXI and CompactPCI modules, providing one system slot and fourteen peripheral slots within a 19‑inch rack‑mountable 6U enclosure.
- PXI and CompactPCI Compatibility: Supports 6U PXI and CompactPCI modules, ensuring flexibility for mixed‑standard test systems.
- PXI Specification Rev. 2.2 Compliance: Fully compliant with PXI standards, including trigger bus, star trigger, local bus, and 10 MHz reference clock distribution.
- 15‑Slot Architecture: One system controller slot and fourteen peripheral slots for modular expansion.
- High‑Power Redundant Supply: Dual hot‑swappable CompactPCI power modules (4 × 250 W for 1000 W total output) with universal 100–240 V AC input.
- Advanced Cooling System: Ten dual‑ball‑bearing fans (five intake, five exhaust) delivering a combined 482 CFM airflow for superior thermal stability.
- System Monitoring and Alarms: Front‑panel LEDs and buzzer alarms for voltage, temperature, and fan status; reset button for alarm acknowledgment.
- Magnetic Circuit Breaker: Integrated AC input protection for electrical safety.
- Hot‑Swappable Components: Power modules and fan trays can be replaced without system downtime, minimizing MTTR.
- Optional Trigger Bus Connectivity: Configurable trigger bus segments for synchronized multi‑module operation.
- Industrial‑Grade Construction: Rugged 19‑inch rackmount chassis with reinforced aluminum frame and UL 94V‑0 rated backplane materials.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8473 3080 000

Comprehensive Product Summary: ADLINK PXIS‑3320/1000W 15‑Slot 6U PXI/CompactPCI Chassis




### 1. Product Overview

Product Name: PXIS‑3320/1000W
Model: PXIS‑3320/1000W
Series: PXIS‑3320 Series PXI/CompactPCI Chassis
Article Number: PXIS‑3320/1000W
Manufacturer: ADLINK Technology Inc.
Part Number: 50‑17024‑1000
Revision: Manual Rev. 2.00 (October 27, 2006)

The ADLINK PXIS‑3320/1000W is a high‑performance, 15‑slot, 6U PXI/CompactPCI chassis designed for modular instrumentation, data acquisition, and automated test applications. It integrates a robust 1000 W hot‑swappable AC power supply system, advanced thermal management, and full compliance with PXI Specification Rev. 2.2. The chassis supports both PXI and CompactPCI modules, providing one system slot and fourteen peripheral slots within a 19‑inch rack‑mountable 6U enclosure.




### 2. Key Features

- PXI and CompactPCI Compatibility: Supports 6U PXI and CompactPCI modules, ensuring flexibility for mixed‑standard test systems.
- PXI Specification Rev. 2.2 Compliance: Fully compliant with PXI standards, including trigger bus, star trigger, local bus, and 10 MHz reference clock distribution.
- 15‑Slot Architecture: One system controller slot and fourteen peripheral slots for modular expansion.
- High‑Power Redundant Supply: Dual hot‑swappable CompactPCI power modules (4 × 250 W for 1000 W total output) with universal 100–240 V AC input.
- Advanced Cooling System: Ten dual‑ball‑bearing fans (five intake, five exhaust) delivering a combined 482 CFM airflow for superior thermal stability.
- System Monitoring and Alarms: Front‑panel LEDs and buzzer alarms for voltage, temperature, and fan status; reset button for alarm acknowledgment.
- Magnetic Circuit Breaker: Integrated AC input protection for electrical safety.
- Hot‑Swappable Components: Power modules and fan trays can be replaced without system downtime, minimizing MTTR.
- Optional Trigger Bus Connectivity: Configurable trigger bus segments for synchronized multi‑module operation.
- Industrial‑Grade Construction: Rugged 19‑inch rackmount chassis with reinforced aluminum frame and UL 94V‑0 rated backplane materials.




### 3. Technical Specifications

Form Factor: 19‑inch rackmount, 6U height
Number of Slots: 15 (1 system + 14 peripheral)
Dimensions: 483 mm (W) × 398 mm (H) × 295 mm (D) (18.8 × 15.5 × 11.5 in) without handles
Weight: 23 kg (50.6 lb)

Power Supply System:
- Type: PICMG 2.11‑compliant CompactPCI power modules
- Configuration: Four × 250 W modules (1000 W total)
- Input Voltage: 100 – 240 V AC, 47 – 63 Hz
- Output Ratings (per module):
- +5 V @ 25 A typ / 33 A max
- +3.3 V @ 18 A typ / 33 A max
- +12 V @ 5 A typ / 5.5 A max
- −12 V @ 0.5 A typ / 1 A max

Cooling System:
- Fans: 10 × 80 mm × 80 mm × 25 mm dual‑ball‑bearing fans
- Airflow: 48.2 CFM per fan (total ≈ 482 CFM)
- Fan Speed: 4000 – 5000 RPM
- Power per Fan: 2.64 W
- Configuration: Five intake fans (bottom), five exhaust fans (top), hot‑swappable trays

Environmental Conditions:
- Operating Temperature: 0 °C – 45 °C (32 °F – 113 °F)
- Storage Temperature: −20 °C – 70 °C (−4 °F – 158 °F)
- Operating Humidity: 10 % – 90 %, non‑condensing
- Storage Humidity: 5 % – 95 %, non‑condensing

Shock and Vibration:
- Shock: 15 G peak‑to‑peak, 11 ms duration
- Vibration (Operating): 5 – 500 Hz, 0.5 G RMS per axis
- Vibration (Non‑Operating): 5 – 500 Hz, 1.88 G RMS per axis

Backplane:
- Material: UL 94V‑0 rated PCB
- Connectors: IEC‑917 and IEC 10764‑101 compliant
- Clock Distribution: 10 MHz PXI_CLK10 with < 1 ns skew between slots
- Trigger Bus: 8‑line PXI trigger bus per segment
- Local Bus: 14‑line bidirectional bus between adjacent slots
- Star Trigger: Dedicated low‑skew (< 1 ns) trigger lines from Slot 2 to Slots 3–15




### 4. Functionality

The PXIS‑3320/1000W serves as the mechanical and electrical foundation for PXI‑based test and measurement systems. It provides power, cooling, and signal routing for up to fifteen 6U PXI or CompactPCI modules.

Operation:
- Slot 1 hosts the PXI system controller (e.g., ADLINK cPCI‑6840 or cPCI‑6860A).
- Slot 2 functions as the star trigger slot, distributing precise trigger signals to peripheral modules.
- Slots 3–15 accommodate measurement, control, or communication modules.
- The backplane’s 10 MHz reference clock and trigger bus enable precise synchronization across modules.

Use Cases:
- Automated test equipment (ATE)
- Data acquisition and signal analysis
- Industrial process control
- Communication and RF testing
- Mixed‑signal instrumentation systems

Compatibility:
- PXI Rev. 2.2 and CompactPCI PICMG 2.0 compliant
- Compatible with ADLINK system controllers and PCI‑to‑PXI remote control interfaces (e.g., PCI‑8570, PXI‑8570/6U).




### 5. Components & Accessories

Included Items:
- PXIS‑3320/1000W chassis (15‑slot, 6U)
- Four × cPS‑H325/AC 250 W CompactPCI power supply modules
- AC power cord
- User’s manual

Optional Accessories:
- System controller modules (cPCI‑6840, cPCI‑6860A)
- PXI‑8570/6U PCI‑to‑PXI extension module
- Trigger bus connectivity (PXIS‑3320/1000W/TB variant)
- Rackmount kits and replacement fan trays

Connectors and Interfaces:
- AC power inlet with magnetic circuit breaker
- Front‑panel LEDs and alarm reset button
- SMB (System Management Bus) connector for monitoring
- ATX‑like DC power input connectors (CN1, CN7, CN8, CN9)
- 10 MHz reference clock jumper (JP1) for internal/external clock selection
- Grounding terminals (GND and FGND)




### 6. Installation & Setup

Requirements:
- Standard 19‑inch rack or stable bench surface
- Proper ventilation clearance above and below chassis
- Grounded AC power source (100–240 V AC)

Installation Steps:
1. Ensure adequate airflow and stable mounting surface.
2. Set power switch to OFF and connect AC power cord.
3. Install system controller in Slot 1, aligning with card guides.
4. Secure controller and peripheral modules with front‑panel screws.
5. Power ON using front‑panel switch; verify LED indicators.

Monitoring & Indicators:
- Power LED (Green): ON = power supplied; OFF = no power.
- Temperature LED (Red): ON = < 50 °C; Flashing = > 50 °C.
- Fan LED (Amber): ON = normal; Flashing = fan failure.
- Buzzer Alarm: Audible alert for power, temperature, or fan faults; reset via front‑panel button.

Maintenance:
- Fans and power modules are hot‑swappable.
- Clean interior with low‑velocity air; exterior with mild soap solution.
- Grounding configuration can be adjusted between signal and frame ground as required.




### 7. Performance & Capabilities

Electrical Performance:
- Stable multi‑rail DC output supporting high‑power PXI modules.
- Current‑sharing redundant power modules ensure uninterrupted operation.
- Low‑noise, high‑efficiency design suitable for precision instrumentation.

Thermal Performance:
- 482 CFM total airflow maintains internal temperature below 50 °C under full load.
- Dual fan decks provide balanced intake and exhaust flow.
- Continuous monitoring prevents overheating and ensures long‑term reliability.

Capacity & Scalability:
- Supports up to 14 peripheral modules plus one system controller.
- Modular backplane allows segmented or unified trigger bus configurations.
- Optional TB variants connect all trigger bus segments for system‑wide synchronization.

Limitations:
- Operating temperature limited to 0–45 °C; requires controlled environment.
- Designed for 6U PXI/CompactPCI modules only (no 3U support).




### 8. Standards & Compliance

PXI Compliance: PXI Specification Rev. 2.2
CompactPCI Compliance: PICMG 2.0 and 2.11
Safety & EMC:
- CE Mark (EN 55024 Immunity)
- FCC Class A Emissions (EN 55022)
- UL 94V‑0 rated materials
Environmental:
- RoHS‑compliant construction (lead‑free)
Mechanical:
- IEC‑917 and IEC 10764‑101 connector standards
Quality Assurance:
- Industrial‑grade design for continuous operation
- Tested for shock (15 G) and vibration (0.5 G RMS operating)




### 9. Additional Information

Warranty:
- Standard two‑year limited warranty (one year in China).
- Covers manufacturing defects; excludes damage from misuse, environmental factors, or unauthorized repair.
- RMA service available via ADLINK’s online portal (http://rma.adlinktech.com).

Support & Service:
- Technical assistance: service@adlinktech.com
- Telephone: +886‑2‑82265877
- Fax: +886‑2‑82265717
- Address: 9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan
- Website: [www.adlinktech.com](http://www.adlinktech.com)

Maintenance Recommendations:
- Periodic inspection of fans and power modules.
- Regular cleaning to prevent dust accumulation.
- Verify grounding and cable integrity during scheduled maintenance.

Safety Precautions:
- Operate within specified temperature and humidity limits.
- Ensure proper grounding and circuit breaker protection.
- Disconnect power before servicing or cleaning.
- Replace lithium battery only with approved type to avoid explosion risk.

Revision History:
- Manual Rev. 2.00 – October 27, 2006
- Specifications updated September 23, 2014




### Summary

The ADLINK PXIS‑3320/1000W is a robust, high‑capacity PXI/CompactPCI chassis engineered for demanding test and measurement environments. Its 15‑slot 6U architecture, redundant 1000 W power system, and advanced thermal management make it ideal for high‑density instrumentation setups. Full PXI 2.2 compliance ensures precise timing and synchronization across modules, while hot‑swappable components and comprehensive monitoring minimize downtime. Certified to CE and FCC standards, the PXIS‑3320/1000W delivers industrial reliability, scalability, and serviceability for automated test, data acquisition, and control applications.

No accessories available.