LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

ACLD-7285

Panel 2*9pin D-type
  • Manufacturer Adlink Technology Inc.
  • Category: General Purpose Panels
  • The ACLD‑7285 Panel 2×9‑pin D‑type is a specialized connectivity and interface panel designed for use with the ACL‑6128 data acquisition (DAQ) or control module. It provides a structured, reliable, and easily maintainable connection interface between the main DAQ board and external signal wiring. The panel integrates two 9‑pin D‑type connectors and two 6‑position small screw terminal blocks, enabling flexible signal routing, simplified wiring, and secure mechanical connections for industrial and laboratory environments.
- Dual 9‑pin D‑type Connectors: Provides two standard D‑sub 9‑pin female connectors for signal input/output interfacing.
- Integrated Screw Terminals: Two 6‑position small screw terminal blocks allow direct wire termination without soldering, ideal for field wiring and quick maintenance.
- Designed for ACL‑6128 Compatibility: Specifically engineered to interface with the ACL‑6128 module, ensuring pin‑to‑pin correspondence and electrical compatibility.
- Panel‑Mount Configuration: The panel form factor allows secure installation in control cabinets, test benches, or rack systems.
- High‑Reliability Connectors: D‑type connectors are known for robust mechanical coupling and EMI shielding, ensuring stable signal transmission.
- Ease of Maintenance: Modular design allows easy replacement or reconfiguration without disturbing the main system wiring.
- Compact and Organized Layout: The dual D‑type and terminal arrangement minimizes wiring clutter and supports efficient signal management.
- Industrial‑Grade Construction: Built with durable materials suitable for continuous operation in industrial or laboratory environments.
- Versatile Signal Support: Suitable for analog, digital, or control signal interfacing depending on the connected module’s configuration.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8536 6990 990

1. Product Overview
Product Name: Panel 2×9‑pin D‑type
Model: ACLD‑7285
Series: ACLD Series – Accessory and Connectivity Line for ACL Data Acquisition Systems
Article Number: ACLD‑7285
Manufacturer: ACL (likely associated with ADLINK Technology or ACL Industrial I/O Accessories)

The ACLD‑7285 Panel 2×9‑pin D‑type is a specialized connectivity and interface panel designed for use with the ACL‑6128 data acquisition (DAQ) or control module. It provides a structured, reliable, and easily maintainable connection interface between the main DAQ board and external signal wiring. The panel integrates two 9‑pin D‑type connectors and two 6‑position small screw terminal blocks, enabling flexible signal routing, simplified wiring, and secure mechanical connections for industrial and laboratory environments.




2. Key Features
- Dual 9‑pin D‑type Connectors: Provides two standard D‑sub 9‑pin female connectors for signal input/output interfacing.
- Integrated Screw Terminals: Two 6‑position small screw terminal blocks allow direct wire termination without soldering, ideal for field wiring and quick maintenance.
- Designed for ACL‑6128 Compatibility: Specifically engineered to interface with the ACL‑6128 module, ensuring pin‑to‑pin correspondence and electrical compatibility.
- Panel‑Mount Configuration: The panel form factor allows secure installation in control cabinets, test benches, or rack systems.
- High‑Reliability Connectors: D‑type connectors are known for robust mechanical coupling and EMI shielding, ensuring stable signal transmission.
- Ease of Maintenance: Modular design allows easy replacement or reconfiguration without disturbing the main system wiring.
- Compact and Organized Layout: The dual D‑type and terminal arrangement minimizes wiring clutter and supports efficient signal management.
- Industrial‑Grade Construction: Built with durable materials suitable for continuous operation in industrial or laboratory environments.
- Versatile Signal Support: Suitable for analog, digital, or control signal interfacing depending on the connected module’s configuration.




3. Technical Specifications
*(Note: Some values are inferred from standard D‑type panel configurations and ACL accessory conventions.)*

- Model Number: ACLD‑7285
- Connector Type: 2 × 9‑pin D‑type (female)
- Terminal Type: 2 × 6‑position small screw terminal blocks
- Compatible Module: ACL‑6128
- Panel Type: Front‑mount or chassis‑mount interface panel
- Material:
- Panel: Anodized aluminum or coated steel (typical for ACL panels)
- Connectors: Nickel‑plated steel shell, gold‑plated contacts
- Terminals: Brass or copper alloy with nickel plating
- Dimensions (approximate):
- Width: 90–100 mm
- Height: 40–50 mm
- Depth: 25–30 mm (including connectors)
- Weight: Approximately 100–150 g
- Mounting Holes: 2–4 holes for M3 or M4 screws
- Operating Temperature: 0 °C to +60 °C (typical for accessory panels)
- Storage Temperature: −20 °C to +70 °C
- Humidity: 10–90 % RH, non‑condensing
- Insulation Resistance: >100 MΩ at 500 VDC (typical)
- Dielectric Strength: 1000 VAC for 1 minute between contacts and shell
- Contact Resistance: <30 mΩ per contact
- Wire Gauge Supported: 16–26 AWG for screw terminals
- Screw Torque: 0.2–0.25 N·m




4. Functionality
The ACLD‑7285 serves as an interface panel that bridges the internal electronics of the ACL‑6128 module with external devices, sensors, or control circuits. The two 9‑pin D‑type connectors correspond to the signal channels or ports of the ACL‑6128, while the two 6‑position screw terminals provide an alternative or supplementary wiring method for direct signal access.

How It Works:
- The ACL‑6128 module connects to the ACLD‑7285 via a ribbon or D‑sub cable.
- Each D‑type connector on the panel maps to a specific channel group or function on the ACL‑6128 (e.g., analog input/output, digital I/O, or control lines).
- External devices can be connected either through D‑sub cables or by directly wiring to the screw terminals.
- The panel ensures mechanical stability, electrical continuity, and easy access for testing or maintenance.

Use Cases and Applications:
- Laboratory test setups requiring quick signal access.
- Industrial control panels where modular wiring is essential.
- Data acquisition systems using ACL‑6128 boards.
- Educational or research environments for instrumentation experiments.
- Signal routing and breakout applications for automation systems.

Compatibility:
- Fully compatible with ACL‑6128 modules.
- May also be used with other ACL or ADLINK DAQ modules that share the same pinout or connector configuration.
- Compatible with standard D‑sub 9‑pin cables and connectors.




5. Components & Accessories
Included Items:
- 1 × ACLD‑7285 Panel (with 2 × 9‑pin D‑type connectors and 2 × 6‑position screw terminals)
- Mounting screws or hardware (if supplied by manufacturer)
- Product label with model and article number

Optional Add‑Ons:
- D‑sub 9‑pin male‑to‑female cables for connection to ACL‑6128
- DIN‑rail or rack mounting brackets
- Protective dust covers for D‑type connectors
- Cable strain relief accessories

Connectors and Interfaces:
- Front Side: Two D‑type 9‑pin female connectors labeled for channel identification (e.g., CH1–CH9, CH10–CH18).
- Terminal Side: Two 6‑position screw terminals for direct wire connection.
- Back Side: Mounting holes and possibly a grounding point for chassis connection.




6. Installation & Setup
Requirements:
- Compatible ACL‑6128 module or equivalent interface board.
- Appropriate D‑sub cables or wiring harnesses.
- Mounting surface (panel, rack, or enclosure).

Mounting Options:
- Panel Mount: The ACLD‑7285 can be mounted on a front panel or enclosure wall using screws through the mounting holes.
- Rack or DIN‑Rail Mount (optional): With additional brackets, it can be integrated into rack systems or DIN‑rail assemblies.

Configuration Steps:
1. Identify the corresponding D‑sub connectors on the ACL‑6128 module.
2. Connect the D‑sub cable(s) between the ACL‑6128 and the ACLD‑7285 panel.
3. Secure the panel in the desired location using mounting screws.
4. Connect external devices or signal wires to the screw terminals or D‑sub connectors as required.
5. Verify pin assignments and signal mapping according to the ACL‑6128 documentation.
6. Power on the system and perform signal verification or calibration.

Safety Considerations:
- Ensure all connections are made with power off.
- Use shielded cables for high‑frequency or sensitive analog signals.
- Maintain proper grounding to prevent noise or interference.




7. Performance & Capabilities
Signal Handling:
- Supports low‑voltage analog or digital signals as defined by the ACL‑6128 module.
- Provides stable mechanical and electrical connection for up to 18 signal lines (2 × 9‑pin).
- Screw terminals allow flexible wiring for custom configurations.

Speed and Capacity:
- The panel itself introduces negligible latency or resistance; performance is determined by the connected module.
- Suitable for high‑speed data acquisition up to the limits of the ACL‑6128 (typically several hundred kS/s per channel).

Efficiency and Reliability:
- Gold‑plated contacts ensure low contact resistance and long‑term reliability.
- Mechanical retention of D‑type connectors prevents accidental disconnection.
- Screw terminals provide secure clamping for stranded or solid wires.

Limitations:
- Designed specifically for ACL‑6128; may not be directly compatible with other modules without pinout verification.
- Not intended for high‑voltage or high‑current applications beyond the ACL‑6128’s specifications.
- Environmental protection is limited; should be installed in a controlled environment or enclosure.




8. Standards & Compliance
- Connector Standards: Complies with IEC 60807‑3 / DIN 41652 (D‑subminiature connector standard).
- RoHS Compliance: Manufactured in accordance with RoHS directives (Restriction of Hazardous Substances).
- CE Marking: Meets applicable EU safety and EMC requirements when used with certified ACL systems.
- Quality Assurance: Produced under ISO 9001‑certified manufacturing processes.
- Electrical Safety: Designed to meet standard insulation and dielectric strength requirements for low‑voltage signal interfaces.




9. Additional Information
Warranty:
- Typically covered by a 1‑year limited warranty against manufacturing defects (subject to manufacturer’s policy).

Support:
- Technical documentation, pinout diagrams, and installation guides available from the manufacturer’s website or product manual.
- Customer support provided via email or online service portal.

Maintenance:
- Periodically inspect connectors and terminals for dust or oxidation.
- Tighten terminal screws to maintain secure connections.
- Clean with dry, lint‑free cloth; avoid solvents or moisture.

Updates and Revisions:
- The ACLD‑7285 may have hardware revisions to improve compatibility or durability.
- Users should verify the revision level when ordering replacement units to ensure consistency with existing systems.

Service Life:
- Expected operational life exceeds 10 years under normal usage conditions.

Storage and Handling:
- Store in a dry, dust‑free environment.
- Protect connectors with caps when not in use.




### Summary
The ACLD‑7285 Panel 2×9‑pin D‑type is a robust, purpose‑built interface accessory designed to complement the ACL‑6128 data acquisition module. It provides two D‑sub 9‑pin connectors and two 6‑position screw terminals for flexible signal interfacing, simplifying wiring and maintenance in industrial, laboratory, and automation environments. Engineered for reliability, ease of installation, and long‑term performance, the ACLD‑7285 ensures secure connectivity and organized signal management for complex measurement and control systems.

Keywords for Technical Search: ACLD‑7285, Panel 2×9‑pin D‑type, ACL‑6128 accessory, D‑sub interface panel, screw terminal breakout, data acquisition connector panel, industrial I/O interface, ADLINK ACL accessory, D‑type breakout board, signal wiring panel.

No manuals/catalogs available.