LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

cPS-150R

cPCI power supply DIN41612, 85..265ACV
  • Manufacturer Adlink Technology Inc.
  • Category: cPCI Power Supplies
  • The ADLINK cPS‑150R is a high‑reliability, hot‑swappable redundant power supply designed for CompactPCI industrial computing platforms. It provides stable, regulated DC outputs for mission‑critical embedded systems and supports parallel current sharing for redundant configurations. The unit is engineered for continuous operation in demanding environments, offering robust protection, compliance with international safety and EMC standards, and compatibility with ADLINK’s cPCIS‑1000 and cPCIS‑2000 chassis families.
- Redundant Hot‑Swappable Design: Enables uninterrupted system operation during PSU replacement or failure.
- Universal AC Input: Accepts 90 – 264 VAC, 45 – 440 Hz single‑phase input, supporting global deployment.
- High Power Density: 175 W maximum output in a compact 3U form factor.
- Multiple DC Outputs: Provides +5 V, +3.3 V, +12 V, and −12 V regulated outputs.
- Parallel Current Sharing: Supports load sharing within ±10 % on +5 V output when multiple units operate in parallel.
- Comprehensive Protection: Over‑current, over‑voltage, under‑voltage, short‑circuit, surge, and over‑temperature protection with automatic recovery.
- Status Indicators: Front‑panel LEDs for “Power OK” (green) and “Fail” (red) status.
- High Efficiency and Power Factor: Typical efficiency 73 %, power factor 0.99.
- Wide Frequency Range: Operates from 45 Hz to 440 Hz, suitable for both commercial and military power systems.
- Industrial Reliability: MTBF ≥ 50,000 hours (MIL‑HDBK‑217E), MTTR ≈ 5 minutes.
- Standards Compliance: Meets UL 1950, CSA C22.2 No. 950, EN 60950/TÜV, CE, FCC Class A, and VDE Class A requirements.
- Environmental Robustness: Operates 0 – 70 °C (full power to 40 °C with 15 CFM airflow), storage −40 – 85 °C, 95 % RH non‑condensing.
- CompactPCI Integration: Fully compliant with PICMG 2.11 power interface standard using 31‑pin DIN 41612 connector.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8504 4030 900

Comprehensive Product Summary: ADLINK cPS‑150R CompactPCI Redundant Power Supply




### 1. Product Overview

Product Name: cPS‑150R
Model: cPS‑150R
Series: cPCIS‑1000/2000 Series Components
Article Number: cPS‑150R
Manufacturer: ADLINK Technology Inc.
Product Type: 3U CompactPCI Redundant Power Supply Unit (PSU)
Connector Standard: DIN 41612, 31‑pin AC‑in/DC‑out interface
Power Rating: 175 W
Input Range: 85 – 265 VAC, 45 – 440 Hz
Intended Platform: 3U CompactPCI industrial computer systems compliant with PICMG 2.11

The ADLINK cPS‑150R is a high‑reliability, hot‑swappable redundant power supply designed for CompactPCI industrial computing platforms. It provides stable, regulated DC outputs for mission‑critical embedded systems and supports parallel current sharing for redundant configurations. The unit is engineered for continuous operation in demanding environments, offering robust protection, compliance with international safety and EMC standards, and compatibility with ADLINK’s cPCIS‑1000 and cPCIS‑2000 chassis families.




### 2. Key Features

- Redundant Hot‑Swappable Design: Enables uninterrupted system operation during PSU replacement or failure.
- Universal AC Input: Accepts 90 – 264 VAC, 45 – 440 Hz single‑phase input, supporting global deployment.
- High Power Density: 175 W maximum output in a compact 3U form factor.
- Multiple DC Outputs: Provides +5 V, +3.3 V, +12 V, and −12 V regulated outputs.
- Parallel Current Sharing: Supports load sharing within ±10 % on +5 V output when multiple units operate in parallel.
- Comprehensive Protection: Over‑current, over‑voltage, under‑voltage, short‑circuit, surge, and over‑temperature protection with automatic recovery.
- Status Indicators: Front‑panel LEDs for “Power OK” (green) and “Fail” (red) status.
- High Efficiency and Power Factor: Typical efficiency 73 %, power factor 0.99.
- Wide Frequency Range: Operates from 45 Hz to 440 Hz, suitable for both commercial and military power systems.
- Industrial Reliability: MTBF ≥ 50,000 hours (MIL‑HDBK‑217E), MTTR ≈ 5 minutes.
- Standards Compliance: Meets UL 1950, CSA C22.2 No. 950, EN 60950/TÜV, CE, FCC Class A, and VDE Class A requirements.
- Environmental Robustness: Operates 0 – 70 °C (full power to 40 °C with 15 CFM airflow), storage −40 – 85 °C, 95 % RH non‑condensing.
- CompactPCI Integration: Fully compliant with PICMG 2.11 power interface standard using 31‑pin DIN 41612 connector.




### 3. Technical Specifications

Electrical Input
- Voltage Range: 90 – 264 VAC, single‑phase
- Input Current: ≤ 3.1 A max
- Inrush Current: < 40 A @ 240 VAC
- Frequency: 45 – 440 Hz
- Power Factor: 0.99 typical
- Efficiency: 73 % typical
- Protection: Over‑current, over‑voltage, under‑voltage, surge suppression

DC Output Ratings
| Output | Voltage | Current (Max) | Regulation | Ripple (p‑p) |
|---------|----------|---------------|-------------|---------------|
| +5 V | 5 V ± 3 % | 20 A (max), 2 A min | ±3 % | 1.0 % |
| +3.3 V | 3.3 V ± 5 % | 12 A | ±5 % | 1.5 % |
| +12 V | 12 V ± 5 % | 2 A | ±5 % | 1.0 % |
| −12 V | −12 V ± 5 % | 1 A | ±5 % | 1.0 % |

- Total Output Power: 175 W max
- Hold‑Up Time: > 6 ms
- Rise Time: < 200 ms
- Temperature Coefficient: 0.05 % / °C
- Load Regulation: ±3 % (+5 V) from 10 % – 100 % load
- Line Regulation: ±0.1 % (+5 V) from 90 – 260 VAC

Mechanical and Physical
- Form Factor: 3U CompactPCI module
- Connector: 31‑pin DIN 41612 (IEC 603‑2 / IEC 1076)
- Dimensions: 3U height, standard CompactPCI depth (approx. 128.5 × 40 × 172 mm)
- Weight: ≈ 0.85 kg
- Cooling: Requires 15 CFM forced air for full‑load operation up to 40 °C

Environmental
- Operating Temperature: 0 – 70 °C (derated above 40 °C)
- Storage Temperature: −40 – 85 °C
- Relative Humidity: < 95 % @ 40 °C, non‑condensing
- Altitude: Up to 6,400 m
- Vibration: 5 – 55 Hz, 0.38 mm displacement, 2 cycles/axis (X, Y, Z)
- Shock: Non‑operating, per IEC 68‑2‑6 equivalent

Insulation Strength
- Primary – Secondary: 4242 Vrms
- Primary – Chassis Ground: 3050 Vrms
- Secondary – Chassis Ground: 500 Vrms
- All outputs and control signals are SELV‑rated and floating relative to chassis ground.




### 4. Functionality

The cPS‑150R converts universal AC mains input into multiple regulated DC outputs required by CompactPCI backplanes and modules. It integrates active power‑factor correction and switching regulation at 100 kHz to achieve high efficiency and low noise.

Operation:
- When inserted into a CompactPCI chassis equipped with a compliant backplane (e.g., cBP‑3051 / 3052), the PSU automatically engages via its 31‑pin DIN 41612 connector.
- The INH# and EN# control signals manage output enable/disable sequencing.
- Current Share (ISH) allows multiple units to operate in parallel for redundancy.
- Sense Lines (5S+, 5S−) compensate for voltage drops across the backplane.
- LED Indicators:
- POWER (Green): AC input present and outputs within regulation.
- FAIL (Red): Indicates fault—over‑voltage, over‑temperature, short‑circuit, or input anomaly.

Use Cases:
- Industrial automation controllers
- Telecommunications CompactPCI systems
- Embedded computing platforms requiring high availability
- Redundant power configurations in 3U/6U CompactPCI chassis

Compatibility:
- Fully compatible with ADLINK cPCIS‑1000 and cPCIS‑2000 chassis families
- Interfaces with backplanes such as cBP‑3051 (single PSU) or cBP‑3052 (dual redundant PSU)
- Mating connectors: ERNI #914374, AMP #148370‑1 / #97‑7200




### 5. Components & Accessories

Included:
- cPS‑150R power supply module
- Integrated front‑panel LEDs and handle for hot‑swap insertion
- Internal protection circuitry

Optional / Related Components:
- Backplanes:
- cBP‑3051 – single 31‑pin PSU backplane
- cBP‑3052 – dual redundant 31‑pin PSU backplane
- Chassis:
- cPCIS‑1000 (3U) and cPCIS‑2000 (3U/4U) enclosures
- Power Supply Frame: cPCI‑PSF for PS2‑size ATX PSU integration
- Drive Bay Frame: cPCI‑DBF for HDD/FDD/CD‑ROM mounting
- LCD Kit: cPCI‑LCD 6.4″ TFT module for system monitoring




### 6. Installation & Setup

Requirements:
- CompactPCI chassis with PICMG 2.11‑compliant 31‑pin power connector (ERNI #914374 / AMP #148370‑1 / #97‑7200).
- Adequate forced‑air cooling (≥ 15 CFM).
- Proper grounding of chassis and backplane.

Procedure:
1. Ensure chassis power switch is OFF.
2. Align PSU with guide rails and insert until the connector fully mates.
3. Secure module using front‑panel latch.
4. Apply AC power; verify green LED illumination.
5. For redundant configurations, insert second PSU into paired slot (e.g., cBP‑3052).

Hot‑Swap Operation:
- The unit supports insertion/removal under power when used with compliant backplanes.
- The INH# and EN# signals ensure safe sequencing.

Caution:
- Forcing insertion into a non‑compliant connector may damage both PSU and backplane.
- Verify connector part numbers before installation.




### 7. Performance & Capabilities

- Rated Power: 175 W max continuous
- Efficiency: 73 % typical at nominal load
- Power Factor: 0.99 typical
- Hold‑Up Time: > 6 ms at full load
- Rise Time: < 200 ms
- Load Sharing: ±10 % on +5 V output in parallel operation
- Thermal Protection: Shutdown at 95 °C internal heatsink temperature, auto‑recovery
- Over‑Voltage Protection: Triggers at +20 % nominal, requires power recycle to reset
- Noise & Ripple: ≤ 1 % p‑p on main outputs
- Operating Envelope: Full power 0 – 40 °C with 15 CFM airflow; derated to 70 °C

Limitations:
- Minimum load of 2 A required on +5 V output for stable regulation.
- Efficiency moderate by modern standards; external cooling mandatory for high‑temperature operation.




### 8. Standards & Compliance

Electrical & Safety:
- UL 1950
- CSA C22.2 No. 950
- EN 60950 / TÜV certified

EMC / EMI:
- FCC Part 15 Class A
- VDE Class A
- CE Marking
- EN 55022 Class A (radiated and conducted)
- EN 61000‑3‑2 (1995) / EN 61000‑3‑3 (harmonics and flicker)

Immunity (EMS):
- EN 50082‑2
- EN 61000‑4‑2 (ESD)
- EN 61000‑4‑3 (RF immunity)
- EN 61000‑4‑4 (EFT/burst)
- EN 61000‑4‑6 (conducted RF)
- EN 61000‑4‑8 (magnetic field)
- ENV 50204 (radiated field from digital radio telephones)

Mechanical & Environmental:
- Designed to meet industrial vibration and shock standards (5 – 55 Hz, 0.38 mm displacement).
- SELV output classification ensures operator safety.




### 9. Additional Information

Warranty:
- One‑year limited warranty from date of purchase against defects in materials and workmanship.
- Excludes damage from misuse, modification, or operation beyond specifications.
- Liability limited to original purchase price; consequential damages excluded.

Maintenance:
- Periodic inspection of connectors and airflow paths recommended.
- Replace failed units via hot‑swap procedure; MTTR ≈ 5 minutes.
- No user‑serviceable internal components.

Support & Service Contacts:
ADLINK Technology Inc.
9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan R.O.C.
Tel: +886‑2‑8226‑5877 Fax: +886‑2‑8226‑5717
Web: [www.adlinktech.com](http://www.adlinktech.com)
Email: service@adlink.com.tw Technical: nuipc@adlink.com.tw

Maintenance Environment:
- Keep ambient temperature within specified range.
- Ensure continuous airflow through chassis fans.
- Clean dust filters regularly in cPCIS‑2000A/B enclosures.

Software/Firmware:
- The PSU itself contains no user‑programmable firmware; system monitoring via backplane signals (FAL#, DEG#, INH#) can be integrated into supervisory software.

Lifecycle & Reliability:
- MTBF ≥ 50,000 hours (MIL‑HDBK‑217E, 25 °C).
- Designed for continuous 24/7 industrial operation.

Associated Systems:
- Commonly deployed in ADLINK cPCIS‑2102, cPCIS‑2151, cPCIS‑2152, and cPCIS‑1151 platforms.
- Compatible with redundant backplanes cBP‑3051 / 3052 for single or dual PSU configurations.




### Summary

The ADLINK cPS‑150R is a robust, industrial‑grade 3U CompactPCI redundant power supply delivering 175 W of regulated DC power from a universal AC input. Its hot‑swappable design, redundant capability, and compliance with PICMG 2.11 make it ideal for high‑availability embedded systems. With comprehensive protection, wide environmental tolerance, and adherence to international safety and EMC standards, the cPS‑150R ensures reliable operation in mission‑critical CompactPCI platforms across automation, telecommunications, and defense applications.
  • cBP-3052 - Power Backplane cPCI 3U for cPS-150R redundant
  • cBP-3052E - Power Backplane cPCI 3U Dual 31 pin
  • cBP-3051 - Power Backplane cPCI 3U Single 31 pin