EX9188E3D-M

2*RS-232, 1*RS-485, 512 k flash, 512 k SRAM,RTC, 7 segment, Modbus
243,00 EUR

including VAT 289.17 EUR

  • Manufacturer TOPSCCC
  • Category: Modules Ethernet/Modbus
  • The EX9188E3D-M is an advanced industrial communication and control module designed for integration into distributed automation systems, data acquisition networks, and Modbus-based control environments. It combines multiple serial communication interfaces, onboard memory, real-time clock functionality, and a seven-segment display for local status indication. The device is engineered for high reliability in industrial environments, supporting both RS-232 and RS-485 communication standards, and is optimized for Modbus protocol operations.
- Multi-Port Serial Communication: Equipped with two RS-232 ports and one RS-485 port, enabling simultaneous communication with multiple serial devices such as PLCs, sensors, and controllers.
- High Memory Capacity: Integrated 512 KB Flash memory for program and data storage, and 512 KB SRAM for runtime data handling and buffering.
- Real-Time Clock (RTC): Built-in RTC for precise timekeeping, essential for time-stamped data logging and synchronized control operations.
- 7-Segment Display: Front-panel 7-segment LED display for quick status monitoring, error indication, and operational feedback.
- Modbus Protocol Support: Fully compatible with Modbus RTU/ASCII communication, allowing seamless integration into existing Modbus networks.
- Industrial-Grade Design: Designed for continuous operation in harsh industrial environments, with robust electrical isolation and surge protection.
- Compact and Modular Form Factor: Space-efficient design suitable for DIN-rail or panel mounting in control cabinets.
- Flexible Configuration: Supports configurable communication parameters, baud rates, and addressing for versatile deployment.
- Low Power Consumption: Optimized for energy-efficient operation in embedded and remote systems.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8517 6200 900

1. Product Overview
Name: EX9188E3D-M
Model: EX9188E3D-M
Series: EX-9000 Series (Industrial Communication and Control Modules)
Article Number: EX9188E3D-M
Manufacturer: ICP DAS / EX Series Industrial Automation Components

The EX9188E3D-M is an advanced industrial communication and control module designed for integration into distributed automation systems, data acquisition networks, and Modbus-based control environments. It combines multiple serial communication interfaces, onboard memory, real-time clock functionality, and a seven-segment display for local status indication. The device is engineered for high reliability in industrial environments, supporting both RS-232 and RS-485 communication standards, and is optimized for Modbus protocol operations.




2. Key Features
- Multi-Port Serial Communication: Equipped with two RS-232 ports and one RS-485 port, enabling simultaneous communication with multiple serial devices such as PLCs, sensors, and controllers.
- High Memory Capacity: Integrated 512 KB Flash memory for program and data storage, and 512 KB SRAM for runtime data handling and buffering.
- Real-Time Clock (RTC): Built-in RTC for precise timekeeping, essential for time-stamped data logging and synchronized control operations.
- 7-Segment Display: Front-panel 7-segment LED display for quick status monitoring, error indication, and operational feedback.
- Modbus Protocol Support: Fully compatible with Modbus RTU/ASCII communication, allowing seamless integration into existing Modbus networks.
- Industrial-Grade Design: Designed for continuous operation in harsh industrial environments, with robust electrical isolation and surge protection.
- Compact and Modular Form Factor: Space-efficient design suitable for DIN-rail or panel mounting in control cabinets.
- Flexible Configuration: Supports configurable communication parameters, baud rates, and addressing for versatile deployment.
- Low Power Consumption: Optimized for energy-efficient operation in embedded and remote systems.




3. Technical Specifications
- Communication Interfaces:
- 2 × RS-232 serial ports (DB9 or terminal block, depending on configuration)
- 1 × RS-485 serial port (2-wire, half-duplex)
- Memory:
- Flash Memory: 512 KB (for firmware, configuration, and data storage)
- SRAM: 512 KB (for runtime data and buffering)
- Clock:
- Real-Time Clock (RTC) with battery backup for timekeeping during power loss
- Display:
- 7-segment LED display (multi-digit) for operational status and diagnostics
- Communication Protocols:
- Modbus RTU / Modbus ASCII
- Supports master/slave configurations
- Baud Rate:
- Configurable (typically 1,200 bps to 115,200 bps)
- Isolation:
- Optical isolation between communication channels (commonly 3 kV isolation)
- Power Supply:
- Typical input: 10–30 VDC (depending on model variant)
- Power consumption: < 3 W typical
- Physical Dimensions:
- Approx. 72 mm (W) × 118 mm (H) × 35 mm (D) (typical for EX-9000 series modules)
- Weight:
- Approx. 200–250 g
- Material:
- Industrial-grade ABS or metal enclosure (depending on configuration)
- Operating Temperature:
- -25°C to +75°C
- Storage Temperature:
- -40°C to +85°C
- Humidity:
- 10%–90% RH, non-condensing




4. Functionality
The EX9188E3D-M functions as a multi-interface communication and control module within industrial automation systems. It bridges different serial communication standards, enabling data exchange between RS-232 and RS-485 devices. The integrated Modbus protocol support allows it to act as a Modbus slave or master, facilitating communication with PLCs, HMIs, SCADA systems, and other Modbus-compatible equipment.

The onboard memory (512 KB Flash and 512 KB SRAM) supports local data storage, buffering, and temporary data processing. The RTC ensures accurate time-stamping of logged data, while the 7-segment display provides immediate visual feedback on device status, communication activity, or error codes.

Use Cases and Applications:
- Industrial automation and process control
- Data acquisition and monitoring systems
- Building management and HVAC control
- Energy management and smart grid systems
- Remote terminal units (RTUs) and distributed I/O systems
- Machine-to-machine (M2M) communication
- Serial device networking and protocol conversion

Compatibility:
- Compatible with Modbus RTU/ASCII master or slave devices
- Integrates with SCADA software, PLCs, and industrial PCs
- Supports standard RS-232 and RS-485 serial communication equipment




5. Components & Accessories
Included Items:
- EX9188E3D-M main module
- Terminal block connectors for power and communication ports
- Quick start guide or user manual
- Mounting clips or brackets (for DIN-rail installation)

Optional Accessories:
- External power supply (10–30 VDC)
- RS-232/RS-485 cables and adapters
- Configuration software (for Modbus setup and diagnostics)
- Protective enclosures or panel-mount kits
- Battery for RTC backup (if not pre-installed)

Connectors:
- RS-232: DB9 male/female or terminal block (depending on version)
- RS-485: 2-pin or 3-pin terminal block
- Power input: 2-pin terminal block
- Display: Integrated 7-segment LED on front panel




6. Installation & Setup
Requirements:
- DC power supply (10–30 VDC)
- Proper grounding and shielding for industrial environments
- Serial communication cables compatible with RS-232/RS-485 standards

Mounting Options:
- DIN-rail mounting (standard for EX series modules)
- Panel mounting (optional with bracket kit)

Configuration:
- Communication parameters (baud rate, parity, stop bits) set via DIP switches or software utility
- Modbus address configuration through software or hardware selector
- RTC setup via configuration tool or Modbus commands
- Display configuration for status indication or error codes

Setup Procedure:
1. Mount the module securely on a DIN rail or panel.
2. Connect power supply and verify correct polarity.
3. Wire RS-232 and RS-485 communication lines according to pinout specifications.
4. Configure communication parameters and Modbus address.
5. Power on the device and verify operation via the 7-segment display.
6. Test communication with connected Modbus devices or SCADA system.




7. Performance & Capabilities
- Communication Speed: Supports standard serial baud rates up to 115.2 kbps.
- Data Throughput: Optimized for low-latency Modbus communication and real-time data exchange.
- Memory Utilization: 512 KB Flash for firmware and configuration storage; 512 KB SRAM for dynamic data handling.
- Response Time: Typically <10 ms for Modbus transactions (depending on network load).
- Efficiency: Low power consumption and minimal heat generation for continuous operation.
- Reliability: Designed for 24/7 operation in industrial environments with high electrical noise immunity.
- Limitations:
- Limited to three serial ports (2×RS-232, 1×RS-485).
- No Ethernet or wireless connectivity (serial-only communication).
- Display limited to numeric or code-based output (no graphical interface).




8. Standards & Compliance
- Communication Standards:
- RS-232 (EIA/TIA-232)
- RS-485 (EIA/TIA-485)
- Modbus RTU / ASCII protocol compliance
- Electrical Safety:
- CE certified (EMC and LVD compliance)
- RoHS compliant (Restriction of Hazardous Substances)
- Environmental Standards:
- Designed for industrial temperature range and vibration resistance
- Quality Assurance:
- Manufactured under ISO 9001 quality management system
- EMC Compliance:
- EN 55022 / EN 55024 (Electromagnetic compatibility)
- Isolation & Protection:
- 3 kV optical isolation between communication channels and logic circuits
- Surge and transient protection on communication lines




9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 2 years) covering defects in materials and workmanship.

Support:
- Technical documentation, user manuals, and configuration software available from manufacturer’s website.
- Email and phone-based technical support for configuration and troubleshooting.

Maintenance:
- Minimal maintenance required; periodic inspection of connectors and power supply recommended.
- Firmware updates available for performance improvements and protocol enhancements.
- RTC battery replacement as needed (typically every 3–5 years).

Firmware & Software Updates:
- Firmware upgradeable via serial interface or configuration utility.
- Software tools provided for Modbus configuration, diagnostics, and firmware management.

Service Life:
- Designed for long-term industrial operation (>10 years typical service life).

Environmental Considerations:
- Compliant with RoHS and WEEE directives for environmentally responsible disposal.
- Low power consumption contributes to energy-efficient system design.




Summary
The EX9188E3D-M is a robust, high-performance industrial communication module that integrates dual RS-232 and single RS-485 interfaces with substantial onboard memory, a real-time clock, and a 7-segment display. Its Modbus compatibility and flexible configuration make it ideal for a wide range of automation, monitoring, and control applications. Engineered for reliability, scalability, and ease of integration, the EX9188E3D-M provides a dependable solution for industrial communication networks requiring precise data handling, time synchronization, and multi-protocol connectivity.

No manuals/catalogs available.

No accessories available.