LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

ILOG110

IP TX to 1*RS232 Isolated 1*RS232 Monitor Data Logger
115,00 EUR

including VAT 136.85 EUR

  • Manufacturer Rayon
  • Category: Serial Data Logger
  • The RAYON iLOG110 is an intelligent IP-to-serial interface converter and data logger designed to provide RS232-to-ground-isolated RS232 communication with real-time monitoring and logging capabilities over Ethernet. It integrates a 10/100 Mbps LAN interface with dual RS232 ports—one standard and one galvanically isolated—to ensure safe, interference-free serial communication in industrial or electrically noisy environments.
- Dual RS232 Ports: One standard RS232 port and one ground-isolated RS232 port (DB9 male connectors).
- Ethernet Connectivity: Auto-detecting 10/100 Mbps RJ45 interface supporting 100Base-T Ethernet.
- Isolation Function: Provides galvanic isolation between two RS232 devices to eliminate ground loops and protect against potential differences.
- Monitoring Capability: Two virtual COM ports allow simultaneous monitoring of bidirectional serial data transmission over IP.
- Data Logging: Acts as a serial data logger, capturing and recording communication sequences for analysis.
- High-Speed Serial Communication: Supports baud rates up to 230,400 bps.
- Embedded Processor: 32-bit 100 MHz MIPS RISC CPU for efficient data handling.
- Memory Resources: 16 MB Flash ROM and 16 MB SDRAM for firmware and buffer storage.
- Cross-Platform Driver Support:
- Windows NT/2000/XP/Vista/7 virtual COM drivers
- Linux raw TTY driver
- SCO UNIX real TTY driver
- Flexible Network Modes: Supports TCP Server/Client and UDP Send/Receive modes.
- Web and Telnet Configuration: Built-in web server and Telnet interface for remote setup and management.
- Low Power Consumption: Operates at 5 VDC, 1200 mA.
- Compact Design: Rugged enclosure suitable for industrial environments.
- Operating Environment: Designed for 5–40°C operation and up to 90% relative humidity.
- Applications: Ideal for industrial automation, SCADA systems, PLC monitoring, serial device debugging, and remote diagnostics.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8517 6200 900

1. Product Overview

Product Name: iLOG110
Model: ILOG110
Series: IP Monitored Interface Isolator / Ethernet-to-Serial Converter
Article Number: ILOG110
Manufacturer: RAYON Technology Co., Ltd.
Manufacturer Address: 2F, No. 177, Chung-Shan 2 Rd., Lu-Chou City, Taipei Hsien, Taiwan
Contact: Tel: +886-2-82858362 | Fax: +886-2-82857065
Email: rayon@ms1.hinet.net
Websites: [www.rayontech.com](http://www.rayontech.com), [www.computex.com.tw/rayon](http://www.computex.com.tw/rayon)

The RAYON iLOG110 is an intelligent IP-to-serial interface converter and data logger designed to provide RS232-to-ground-isolated RS232 communication with real-time monitoring and logging capabilities over Ethernet. It integrates a 10/100 Mbps LAN interface with dual RS232 ports—one standard and one galvanically isolated—to ensure safe, interference-free serial communication in industrial or electrically noisy environments. The device functions as both a serial isolator and a network-enabled data monitor, allowing users to observe, record, and simulate serial communication remotely via TCP/IP or UDP/IP networks.




2. Key Features

- Dual RS232 Ports: One standard RS232 port and one ground-isolated RS232 port (DB9 male connectors).
- Ethernet Connectivity: Auto-detecting 10/100 Mbps RJ45 interface supporting 100Base-T Ethernet.
- Isolation Function: Provides galvanic isolation between two RS232 devices to eliminate ground loops and protect against potential differences.
- Monitoring Capability: Two virtual COM ports allow simultaneous monitoring of bidirectional serial data transmission over IP.
- Data Logging: Acts as a serial data logger, capturing and recording communication sequences for analysis.
- High-Speed Serial Communication: Supports baud rates up to 230,400 bps.
- Embedded Processor: 32-bit 100 MHz MIPS RISC CPU for efficient data handling.
- Memory Resources: 16 MB Flash ROM and 16 MB SDRAM for firmware and buffer storage.
- Cross-Platform Driver Support:
- Windows NT/2000/XP/Vista/7 virtual COM drivers
- Linux raw TTY driver
- SCO UNIX real TTY driver
- Flexible Network Modes: Supports TCP Server/Client and UDP Send/Receive modes.
- Web and Telnet Configuration: Built-in web server and Telnet interface for remote setup and management.
- Low Power Consumption: Operates at 5 VDC, 1200 mA.
- Compact Design: Rugged enclosure suitable for industrial environments.
- Operating Environment: Designed for 5–40°C operation and up to 90% relative humidity.
- Applications: Ideal for industrial automation, SCADA systems, PLC monitoring, serial device debugging, and remote diagnostics.




3. Technical Specifications

| Parameter | Specification |
|----------------|-------------------|
| CPU | 32-bit MIPS RISC, 100 MHz |
| Flash ROM | 16 MB |
| SDRAM | 16 MB |
| Ethernet Interface | 10/100 Mbps, 100Base-T, RJ45 connector |
| Serial Ports | 2 × RS232 (DB9 male) |
| Isolation | One port ground-isolated |
| Baud Rate | Up to 230,400 bps |
| Power Supply | 5 VDC @ 1200 mA |
| Dimensions | 92 × 118 × 27 mm |
| Material | Industrial-grade enclosure (Rayon standard) |
| Operating Temperature | 5–40°C |
| Storage Temperature | 0–65°C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Storage Humidity | 5–90% RH |
| Weight | Approx. 0.3 kg (typical) |
| Network Protocols | TCP/IP, UDP/IP |
| Configuration Interfaces | Web browser, Telnet, Console terminal |
| Driver Support | Windows, Linux, UNIX |
| Isolation Voltage | Ground isolation between serial ports (typical 1 kV DC isolation) |




4. Functionality

The iLOG110 serves as both an RS232 isolator and an Ethernet-based serial monitor/logger. It connects two RS232 devices—such as a PLC and a motor controller—while isolating their ground references to prevent electrical interference or damage caused by potential differences.

Operational Logic:
- Data received on Serial Port 1 is retransmitted to Serial Port 2 and simultaneously sent to Virtual COM Port 1 over the IP network.
- Data received on Serial Port 2 is retransmitted to Serial Port 1 and sent to Virtual COM Port 2.
- Data sent from Virtual COM Port 1 or Virtual COM Port 2 is transmitted to the corresponding physical serial port, enabling remote simulation or testing.

Use Cases:
- Industrial Control Systems: Monitor communication between PLCs, sensors, and actuators.
- SCADA and Automation: Capture and analyze serial data exchanges in distributed control networks.
- Device Debugging: Identify communication errors between serial devices without interrupting operation.
- Remote Diagnostics: Access and log serial data from distant equipment via LAN.
- Data Simulation: Emulate serial devices for testing and troubleshooting.

Compatibility:
- Works with Windows (NT through 7), Linux, and UNIX systems.
- Supports both TCP and UDP communication modes for flexible integration with existing network architectures.
- Compatible with RAYON’s RAYREAL monitoring software for real-time data visualization and analysis.




5. Components & Accessories

Included Items:
- iLOG110 main unit
- User manual and software CD (includes drivers and RAYREAL utility)
- Power adapter (5 VDC)
- Ethernet cable (optional, depending on package)

Connectors:
- LAN Port: RJ45, 10/100 Mbps auto-sensing
- Serial Ports: Two DB9 male connectors
- Port 1: Standard RS232
- Port 2: Ground-isolated RS232
- Console Port: Shared with Serial Port 1 for configuration

Optional Accessories:
- UP110/UP220 5VDC power adapters
- RS232 null modem cables
- DIN-rail mounting kit
- Additional RAYON monitoring utilities (RAYREAL software suite)




6. Installation & Setup

Requirements:
- 5 VDC regulated power supply (use only RAYON-approved adapters)
- Ethernet connection to LAN or switch
- PC with Windows, Linux, or UNIX OS for configuration and monitoring

Installation Steps:
1. Connect the iLOG110 to the LAN using an RJ45 cable.
2. Connect RS232 devices to the DB9 ports (Port 1 and Port 2).
3. Power on the device using the supplied 5V adapter.
4. Configure network parameters via Web, Telnet, or console interface.
5. Install the appropriate virtual COM or TTY driver on the host PC.
6. Assign IP address, subnet mask, and gateway (static IP recommended).
7. Verify connectivity using ping or RAYON’s search utility.
8. Launch RAYREAL or terminal software to monitor and log serial data.

Mounting Options:
- Desktop placement
- Optional DIN-rail or wall mounting for industrial environments

Configuration Interfaces:
- Web Interface: Accessible via browser (default IP 192.168.1.254, password 11111)
- Telnet Interface: Command-line configuration for advanced users
- Console Port: Serial terminal setup (115200 bps, 8N1)




7. Performance & Capabilities

- Data Throughput: Up to 230.4 kbps per serial channel
- Network Speed: Auto-sensing 10/100 Mbps Ethernet
- Latency: Optimized for low-delay serial-to-IP conversion
- CPU Performance: 100 MHz RISC processor ensures stable real-time operation
- Memory Utilization: 16 MB SDRAM for buffering and 16 MB Flash for firmware and logs
- Reliability: Continuous operation in industrial environments with minimal downtime
- Efficiency: Low power consumption (6 W typical)
- Limitations:
- Designed for RS232 communication only (no RS422/RS485 support)
- Requires external PC for data logging and analysis
- Isolation limited to one serial port




8. Standards & Compliance

- Ethernet Standards: IEEE 802.3 10/100Base-T
- Serial Communication: EIA/TIA RS232 standard
- Network Protocols: TCP/IP, UDP/IP, Telnet, HTTP
- Driver Standards:
- Windows Virtual COM (NT/2000/XP/Vista/7)
- Linux Raw TTY
- SCO UNIX Real TTY
- Safety & Isolation: Ground isolation between serial ports to prevent electrical damage
- Environmental Compliance: Designed for industrial-grade temperature and humidity ranges
- Firmware Upgrade: Supported via TFTP (factory IP 192.168.1.254)
- Regulatory Compliance: CE and FCC Class A (typical for RAYON industrial devices)




9. Additional Information

Warranty:
- Standard 1-year limited warranty covering defects in materials and workmanship.
- Excludes damage from misuse, electrical surges, or unauthorized servicing.
- RMA (Return Material Authorization) required for repairs.

Support & Maintenance:
- Technical support via email (rayon@ms1.hinet.net).
- Firmware updates available through RAYON’s website.
- RAYREAL software provided for monitoring and analysis, with source code for customization.
- Optional extended support and integration assistance for OEM and industrial clients.

Maintenance Recommendations:
- Use only approved 5VDC adapters.
- Avoid exposure to extreme temperatures or humidity.
- Periodically back up configuration and log data.
- Update firmware as recommended by RAYON for performance and security improvements.

Firmware Upgrade Procedure:
1. Set DIP switch bit 2 to ON for firmware upgrade mode.
2. Connect via console terminal (115200 bps, 8N1).
3. Use TFTP client to upload new firmware image to 192.168.1.254.
4. Restart device after successful transfer.

Related Products:
- iLOG101: RS232 to ground-isolated RS422/RS485 converter with IP monitoring.
- APORT200/400/800 Series: Multi-port Ethernet-to-serial converters.
- ULOG301-I / ULOG310-I: USB-based monitored interface converters with isolation.
- APLOG301-I: PCI-based monitored interface card for RS232/RS422/RS485.

Software Integration:
- RAYREAL Utility: Displays and logs data from both serial ports with time-stamped records.
- RAYMON Terminal Emulator: For ASCII/HEX data visualization.
- Driver Packages: Include APORT and TPORT virtual COM drivers for Windows and UNIX systems.

Applications Summary:
- Industrial automation and control
- SCADA and telemetry systems
- Serial communication diagnostics
- Remote equipment monitoring
- Data acquisition and logging
- Laboratory and research instrumentation




Summary

The RAYON iLOG110 IP-to-RS232 Isolated Data Logger is a robust, network-enabled serial communication tool engineered for industrial and technical environments requiring safe, isolated, and remotely monitored RS232 communication. Its dual-port design, Ethernet connectivity, and comprehensive driver support make it a versatile solution for engineers, integrators, and developers who need to monitor, log, and analyze serial data without disrupting existing systems. With its combination of hardware isolation, intelligent data routing, and cross-platform compatibility, the iLOG110 stands as a reliable “black box” for serial communication networks—enhancing diagnostic capability, system reliability, and operational safety.