LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- Industrial-grade design: Fully compliant with IEC 61850-3 and IEEE 1613 for substation and railway applications.
- EN50155 compliance: Suitable for rolling stock and railway communication systems.
- Rugged M12 connectors: Ensures vibration-resistant and shockproof Ethernet connections.
- Wide operating temperature: -40°C to +85°C for extreme environmental conditions.
- Dual redundant power inputs: 12–48 VDC on terminal block plus 12–45 VDC on power jack for high reliability.
- Link Fault Pass-through (LFP): Provides immediate link failure detection and system response.
- Auto MDI/MDI-X and auto-negotiation: Simplifies network setup and cabling.
- Store-and-forward switching: Guarantees reliable data transmission with error checking.
- Relay output for power failure alarm: Enables external alerting systems for power loss events.
- Configurable DIP-switches: Allows manual control of LFP, speed, duplex, and alarm settings.
- IP-30 metal enclosure: Provides mechanical protection and EMI shielding.
- DIN-rail and wall-mount options: Flexible installation for industrial cabinets or control panels.
- LED indicators: Comprehensive status display for power, link, duplex, and fault conditions.
- High reliability: Designed for continuous operation in mission-critical environments.
- EN50155 compliance: Suitable for rolling stock and railway communication systems.
- Rugged M12 connectors: Ensures vibration-resistant and shockproof Ethernet connections.
- Wide operating temperature: -40°C to +85°C for extreme environmental conditions.
- Dual redundant power inputs: 12–48 VDC on terminal block plus 12–45 VDC on power jack for high reliability.
- Link Fault Pass-through (LFP): Provides immediate link failure detection and system response.
- Auto MDI/MDI-X and auto-negotiation: Simplifies network setup and cabling.
- Store-and-forward switching: Guarantees reliable data transmission with error checking.
- Relay output for power failure alarm: Enables external alerting systems for power loss events.
- Configurable DIP-switches: Allows manual control of LFP, speed, duplex, and alarm settings.
- IP-30 metal enclosure: Provides mechanical protection and EMI shielding.
- DIN-rail and wall-mount options: Flexible installation for industrial cabinets or control panels.
- LED indicators: Comprehensive status display for power, link, duplex, and fault conditions.
- High reliability: Designed for continuous operation in mission-critical environments.
Comprehensive Product Summary – IMC-P111FX-SS-SC-M12-LV Industrial Media Converter
### 1. Product Overview
Product Name: Industrial Media Converter IEC-61850 1×100TX to 100FX SS SC M12 24V
Model: IMC-P111FX-SS-SC-M12-LV
Series: IMC-P111FX / IMC-P111P M12 Series
Article Number: IMC-P111FX-SS-SC-M12-LV
Manufacturer: ORing Industrial Networking Corp.
Version: 1.0
The IMC-P111FX-SS-SC-M12-LV is a rugged, industrial-grade Ethernet-to-fiber media converter designed for mission-critical applications in power substations, railway systems, and other harsh industrial environments. Fully compliant with IEC 61850-3 and IEEE 1613 standards, it ensures reliable data transmission under extreme temperature, vibration, and electromagnetic conditions. The unit converts one 10/100Base-T(X) Ethernet port (M12 D-coded connector) to one 100Base-FX single-mode fiber port (SC connector), supporting up to 30 km transmission distance at 1310 nm wavelength.
### 2. Key Features
- Industrial-grade design: Fully compliant with IEC 61850-3 and IEEE 1613 for substation and railway applications.
- EN50155 compliance: Suitable for rolling stock and railway communication systems.
- Rugged M12 connectors: Ensures vibration-resistant and shockproof Ethernet connections.
- Wide operating temperature: -40°C to +85°C for extreme environmental conditions.
- Dual redundant power inputs: 12–48 VDC on terminal block plus 12–45 VDC on power jack for high reliability.
- Link Fault Pass-through (LFP): Provides immediate link failure detection and system response.
- Auto MDI/MDI-X and auto-negotiation: Simplifies network setup and cabling.
- Store-and-forward switching: Guarantees reliable data transmission with error checking.
- Relay output for power failure alarm: Enables external alerting systems for power loss events.
- Configurable DIP-switches: Allows manual control of LFP, speed, duplex, and alarm settings.
- IP-30 metal enclosure: Provides mechanical protection and EMI shielding.
- DIN-rail and wall-mount options: Flexible installation for industrial cabinets or control panels.
- LED indicators: Comprehensive status display for power, link, duplex, and fault conditions.
- High reliability: Designed for continuous operation in mission-critical environments.
### 3. Technical Specifications
Physical Characteristics
- Enclosure: IP-30 rated metal housing
- Dimensions (W × D × H): 54.2 × 106.1 × 145.4 mm (2.05 × 4.18 × 5.68 in)
- Weight: 691 g (LV model)
- Mounting: DIN-rail and wall-mount compatible
Ethernet Interface
- Port: 1 × 10/100Base-T(X) M12 D-coded connector (Auto MDI/MDI-X)
- Standards: IEEE 802.3 (10Base-T), IEEE 802.3u (100Base-TX/FX), IEEE 802.3x (Flow Control)
- Processing: Store-and-forward switching
Fiber Interface
- Port: 1 × 100Base-FX single-mode SC connector
- Fiber Type: 9/125 µm single-mode
- Wavelength: 1310 nm
- Transmission Distance: Up to 30 km
- Optical Power:
- Max Output: -8 dBm
- Min Output: -15 dBm
- Max Input (Saturation): 0 dBm
- Min Input (Sensitivity): -34 dBm
- Link Budget: 19 dB
Power Supply
- Input Voltage: Dual 12–48 VDC (7-pin terminal block) + 12–45 VDC (power jack)
- Power Consumption: 12 W (typical)
- Protection: Overload current and reverse polarity protection
- Relay Output: Power failure alarm relay contact
Environmental Conditions
- Operating Temperature: -40°C to +85°C (-40°F to +185°F)
- Storage Temperature: -40°C to +85°C (-40°F to +185°F)
- Humidity: 5%–95% non-condensing
### 4. Functionality
The IMC-P111FX-SS-SC-M12-LV functions as a media converter bridging copper Ethernet and fiber optic networks. It converts electrical Ethernet signals (10/100Base-TX) to optical signals (100Base-FX), enabling long-distance data transmission up to 30 km over single-mode fiber.
Operational Features:
- Auto-negotiation: Automatically detects link speed (10/100 Mbps) and duplex mode.
- Auto MDI/MDI-X: Eliminates the need for crossover cables.
- LFP (Link Fault Pass-through): When one link fails, the converter disables the corresponding link on the opposite side, allowing network management systems to detect and respond to failures immediately.
- Full/Half Duplex Support: Configurable via DIP-switch for both Ethernet and fiber ports.
- Relay Alarm Output: Provides external signaling for power failure or link fault events.
Use Cases:
- Power substations and smart grid communication (IEC 61850-3 environments)
- Railway and rolling stock Ethernet backbone (EN50155 compliance)
- Industrial automation and process control networks
- Remote monitoring and SCADA systems
- Long-distance Ethernet extension over fiber
Compatibility:
- Compatible with standard Ethernet devices (switches, PLCs, RTUs, routers)
- Supports both multi-mode and single-mode fiber configurations (depending on model variant)
### 5. Components & Accessories
Included in Package:
- IMC-P111FX-SS-SC-M12-LV unit × 1
- DIN-rail mounting kit × 1
- Wall-mount kit × 1
- Quick Installation Guide × 1
Optional Accessories:
- SFP100 Series: 100 Mbps SFP optical transceivers (for IMC-P111P models)
- DR-45 Series: 45 W industrial power supply
- DR-75 Series: 75 W industrial power supply
- DR-120 Series: 120 W industrial power supply
Connectors:
- Ethernet: 4-pin female M12 D-coded connector
- Fiber: SC single-mode connector
- Power: 7-pin terminal block + DC power jack
- Relay Output: Terminal block contacts for alarm signaling
### 6. Installation & Setup
Mounting Options:
- DIN-Rail Installation:
1. Attach the DIN-rail kit to the back panel using provided screws.
2. Slide the converter onto the DIN-rail until it clicks securely.
- Wall-Mount Installation:
1. Attach wall-mount plates using six screws.
2. Mark and drill holes on the wall according to the plate layout.
3. Hang the unit using keyhole slots and tighten screws for stability.
Power Wiring (LV Model):
- Connect dual DC inputs (12–48 VDC) to the terminal block labeled V1+/V1– and V2+/V2–.
- Optional third DC input (12–45 VDC) via power jack.
- Relay output terminals provide alarm signaling for power failure.
- Ensure proper grounding to minimize EMI interference.
Network Connection:
- Use CAT 5 or higher UTP cables (100 Ω) for 10/100Base-TX Ethernet connections (max 100 m).
- Connect the fiber SC port to corresponding RX/TX ports on remote devices.
- Verify link status via LED indicators.
DIP-Switch Configuration:
- Switch 1: LFP mode (ON = enable, OFF = disable)
- Switch 2: Ethernet speed (ON = 10 Mbps, OFF = auto 10/100 Mbps)
- Switch 3: Ethernet duplex (ON = half, OFF = auto full/half)
- Switch 4: Fiber duplex (ON = half, OFF = full)
- Alarm DIP-Switch 1: Power-1 failure alarm (ON = enable)
- Alarm DIP-Switch 2: Power-2 failure alarm (ON = enable)
### 7. Performance & Capabilities
Transmission Performance:
- Ethernet Speed: 10/100 Mbps auto-negotiation
- Fiber Speed: 100 Mbps full-duplex
- Distance: Up to 30 km (single-mode fiber)
- Latency: Low-latency store-and-forward switching
- Link Budget: 19 dB (single-mode)
Reliability & Redundancy:
- Dual redundant DC power inputs ensure uninterrupted operation.
- Relay alarm output provides immediate fault notification.
- LFP function enhances network fault tolerance.
Efficiency:
- Typical power consumption: 12 W
- Passive cooling design with no moving parts for silent operation.
Limitations:
- Supports Fast Ethernet (100 Mbps) only; not Gigabit-capable.
- Single fiber port; no fiber redundancy.
### 8. Standards & Compliance
Industrial & Power Automation Standards:
- IEC 61850-3 (Power Substation Communication)
- IEEE 1613 (Electric Power Substation Networking Equipment)
Railway Standards:
- EN50155 (Rolling Stock Equipment)
- EN50121-3-2, EN50121-4 (Railway EMC)
EMI/EMS Compliance:
- FCC Part 15 Class A
- CISPR (EN55022) Class A
- EN55011 Industrial, Scientific, and Medical (ISM) equipment
- EN61000-4-2 (ESD)
- EN61000-4-3 (Radiated Susceptibility)
- EN61000-4-4 (EFT/Burst)
- EN61000-4-5 (Surge)
- EN61000-4-6 (Conducted Susceptibility)
- EN61000-4-8 (Magnetic Field Immunity)
- EN61000-4-11 (Voltage Dips and Interruptions)
Mechanical & Safety Standards:
- IEC60068-2-6 (Vibration)
- IEC60068-2-27 (Shock)
- IEC60068-2-32 (Free Fall)
- EN60950-1 (Safety of IT Equipment)
Ingress Protection:
- IP-30 rated enclosure
### 9. Additional Information
Warranty: 5 years limited warranty
Support:
- Technical support via ORing Industrial Networking Corp.
- Email: support@oring-networking.com
- Website: [www.oring-networking.com](http://www.oring-networking.com)
- Tel: +886-2-2218-1066 | Fax: +886-2-2218-1014
Maintenance:
- Periodic inspection of connectors and power terminals recommended.
- Ensure fiber connectors are clean and dust-free.
- Verify LED indicators regularly for link and power status.
Firmware & Updates:
- Hardware-based device; no firmware updates required for standard operation.
- Configuration via DIP-switches only (no software interface).
Ordering Information:
- IMC-P111FX-MM-SC-M12-LV: Multi-mode, 2 km, 1310 nm, SC connector, LV power
- IMC-P111FX-SS-SC-M12-LV: Single-mode, 30 km, 1310 nm, SC connector, LV power *(this model)*
- IMC-P111FX-MM/SS-SC-M12-HV_xx: High-voltage variants with regional power cords (US, UK, EU, JP)
- IMC-P111P-M12-LV/HV: SFP socket variants for flexible fiber modules
### Summary
The ORing IMC-P111FX-SS-SC-M12-LV is a high-reliability, industrial-grade Ethernet-to-fiber media converter engineered for demanding environments such as power substations and railway systems. It provides robust connectivity between copper and fiber networks, ensuring long-distance, interference-free communication. With compliance to IEC 61850-3, IEEE 1613, and EN50155 standards, it guarantees performance under extreme conditions.
Its rugged IP-30 enclosure, M12 connectors, wide temperature tolerance, and redundant power inputs make it ideal for mission-critical applications requiring continuous uptime. The integrated LFP function, configurable DIP-switches, and relay alarm output enhance operational reliability and simplify maintenance.
This model’s single-mode SC fiber port supports up to 30 km transmission, making it suitable for extended network backbones in industrial automation, transportation, and energy sectors. With a 5-year warranty and ORing’s proven industrial networking expertise, the IMC-P111FX-SS-SC-M12-LV delivers dependable, long-term performance in the harshest environments.
### 1. Product Overview
Product Name: Industrial Media Converter IEC-61850 1×100TX to 100FX SS SC M12 24V
Model: IMC-P111FX-SS-SC-M12-LV
Series: IMC-P111FX / IMC-P111P M12 Series
Article Number: IMC-P111FX-SS-SC-M12-LV
Manufacturer: ORing Industrial Networking Corp.
Version: 1.0
The IMC-P111FX-SS-SC-M12-LV is a rugged, industrial-grade Ethernet-to-fiber media converter designed for mission-critical applications in power substations, railway systems, and other harsh industrial environments. Fully compliant with IEC 61850-3 and IEEE 1613 standards, it ensures reliable data transmission under extreme temperature, vibration, and electromagnetic conditions. The unit converts one 10/100Base-T(X) Ethernet port (M12 D-coded connector) to one 100Base-FX single-mode fiber port (SC connector), supporting up to 30 km transmission distance at 1310 nm wavelength.
### 2. Key Features
- Industrial-grade design: Fully compliant with IEC 61850-3 and IEEE 1613 for substation and railway applications.
- EN50155 compliance: Suitable for rolling stock and railway communication systems.
- Rugged M12 connectors: Ensures vibration-resistant and shockproof Ethernet connections.
- Wide operating temperature: -40°C to +85°C for extreme environmental conditions.
- Dual redundant power inputs: 12–48 VDC on terminal block plus 12–45 VDC on power jack for high reliability.
- Link Fault Pass-through (LFP): Provides immediate link failure detection and system response.
- Auto MDI/MDI-X and auto-negotiation: Simplifies network setup and cabling.
- Store-and-forward switching: Guarantees reliable data transmission with error checking.
- Relay output for power failure alarm: Enables external alerting systems for power loss events.
- Configurable DIP-switches: Allows manual control of LFP, speed, duplex, and alarm settings.
- IP-30 metal enclosure: Provides mechanical protection and EMI shielding.
- DIN-rail and wall-mount options: Flexible installation for industrial cabinets or control panels.
- LED indicators: Comprehensive status display for power, link, duplex, and fault conditions.
- High reliability: Designed for continuous operation in mission-critical environments.
### 3. Technical Specifications
Physical Characteristics
- Enclosure: IP-30 rated metal housing
- Dimensions (W × D × H): 54.2 × 106.1 × 145.4 mm (2.05 × 4.18 × 5.68 in)
- Weight: 691 g (LV model)
- Mounting: DIN-rail and wall-mount compatible
Ethernet Interface
- Port: 1 × 10/100Base-T(X) M12 D-coded connector (Auto MDI/MDI-X)
- Standards: IEEE 802.3 (10Base-T), IEEE 802.3u (100Base-TX/FX), IEEE 802.3x (Flow Control)
- Processing: Store-and-forward switching
Fiber Interface
- Port: 1 × 100Base-FX single-mode SC connector
- Fiber Type: 9/125 µm single-mode
- Wavelength: 1310 nm
- Transmission Distance: Up to 30 km
- Optical Power:
- Max Output: -8 dBm
- Min Output: -15 dBm
- Max Input (Saturation): 0 dBm
- Min Input (Sensitivity): -34 dBm
- Link Budget: 19 dB
Power Supply
- Input Voltage: Dual 12–48 VDC (7-pin terminal block) + 12–45 VDC (power jack)
- Power Consumption: 12 W (typical)
- Protection: Overload current and reverse polarity protection
- Relay Output: Power failure alarm relay contact
Environmental Conditions
- Operating Temperature: -40°C to +85°C (-40°F to +185°F)
- Storage Temperature: -40°C to +85°C (-40°F to +185°F)
- Humidity: 5%–95% non-condensing
### 4. Functionality
The IMC-P111FX-SS-SC-M12-LV functions as a media converter bridging copper Ethernet and fiber optic networks. It converts electrical Ethernet signals (10/100Base-TX) to optical signals (100Base-FX), enabling long-distance data transmission up to 30 km over single-mode fiber.
Operational Features:
- Auto-negotiation: Automatically detects link speed (10/100 Mbps) and duplex mode.
- Auto MDI/MDI-X: Eliminates the need for crossover cables.
- LFP (Link Fault Pass-through): When one link fails, the converter disables the corresponding link on the opposite side, allowing network management systems to detect and respond to failures immediately.
- Full/Half Duplex Support: Configurable via DIP-switch for both Ethernet and fiber ports.
- Relay Alarm Output: Provides external signaling for power failure or link fault events.
Use Cases:
- Power substations and smart grid communication (IEC 61850-3 environments)
- Railway and rolling stock Ethernet backbone (EN50155 compliance)
- Industrial automation and process control networks
- Remote monitoring and SCADA systems
- Long-distance Ethernet extension over fiber
Compatibility:
- Compatible with standard Ethernet devices (switches, PLCs, RTUs, routers)
- Supports both multi-mode and single-mode fiber configurations (depending on model variant)
### 5. Components & Accessories
Included in Package:
- IMC-P111FX-SS-SC-M12-LV unit × 1
- DIN-rail mounting kit × 1
- Wall-mount kit × 1
- Quick Installation Guide × 1
Optional Accessories:
- SFP100 Series: 100 Mbps SFP optical transceivers (for IMC-P111P models)
- DR-45 Series: 45 W industrial power supply
- DR-75 Series: 75 W industrial power supply
- DR-120 Series: 120 W industrial power supply
Connectors:
- Ethernet: 4-pin female M12 D-coded connector
- Fiber: SC single-mode connector
- Power: 7-pin terminal block + DC power jack
- Relay Output: Terminal block contacts for alarm signaling
### 6. Installation & Setup
Mounting Options:
- DIN-Rail Installation:
1. Attach the DIN-rail kit to the back panel using provided screws.
2. Slide the converter onto the DIN-rail until it clicks securely.
- Wall-Mount Installation:
1. Attach wall-mount plates using six screws.
2. Mark and drill holes on the wall according to the plate layout.
3. Hang the unit using keyhole slots and tighten screws for stability.
Power Wiring (LV Model):
- Connect dual DC inputs (12–48 VDC) to the terminal block labeled V1+/V1– and V2+/V2–.
- Optional third DC input (12–45 VDC) via power jack.
- Relay output terminals provide alarm signaling for power failure.
- Ensure proper grounding to minimize EMI interference.
Network Connection:
- Use CAT 5 or higher UTP cables (100 Ω) for 10/100Base-TX Ethernet connections (max 100 m).
- Connect the fiber SC port to corresponding RX/TX ports on remote devices.
- Verify link status via LED indicators.
DIP-Switch Configuration:
- Switch 1: LFP mode (ON = enable, OFF = disable)
- Switch 2: Ethernet speed (ON = 10 Mbps, OFF = auto 10/100 Mbps)
- Switch 3: Ethernet duplex (ON = half, OFF = auto full/half)
- Switch 4: Fiber duplex (ON = half, OFF = full)
- Alarm DIP-Switch 1: Power-1 failure alarm (ON = enable)
- Alarm DIP-Switch 2: Power-2 failure alarm (ON = enable)
### 7. Performance & Capabilities
Transmission Performance:
- Ethernet Speed: 10/100 Mbps auto-negotiation
- Fiber Speed: 100 Mbps full-duplex
- Distance: Up to 30 km (single-mode fiber)
- Latency: Low-latency store-and-forward switching
- Link Budget: 19 dB (single-mode)
Reliability & Redundancy:
- Dual redundant DC power inputs ensure uninterrupted operation.
- Relay alarm output provides immediate fault notification.
- LFP function enhances network fault tolerance.
Efficiency:
- Typical power consumption: 12 W
- Passive cooling design with no moving parts for silent operation.
Limitations:
- Supports Fast Ethernet (100 Mbps) only; not Gigabit-capable.
- Single fiber port; no fiber redundancy.
### 8. Standards & Compliance
Industrial & Power Automation Standards:
- IEC 61850-3 (Power Substation Communication)
- IEEE 1613 (Electric Power Substation Networking Equipment)
Railway Standards:
- EN50155 (Rolling Stock Equipment)
- EN50121-3-2, EN50121-4 (Railway EMC)
EMI/EMS Compliance:
- FCC Part 15 Class A
- CISPR (EN55022) Class A
- EN55011 Industrial, Scientific, and Medical (ISM) equipment
- EN61000-4-2 (ESD)
- EN61000-4-3 (Radiated Susceptibility)
- EN61000-4-4 (EFT/Burst)
- EN61000-4-5 (Surge)
- EN61000-4-6 (Conducted Susceptibility)
- EN61000-4-8 (Magnetic Field Immunity)
- EN61000-4-11 (Voltage Dips and Interruptions)
Mechanical & Safety Standards:
- IEC60068-2-6 (Vibration)
- IEC60068-2-27 (Shock)
- IEC60068-2-32 (Free Fall)
- EN60950-1 (Safety of IT Equipment)
Ingress Protection:
- IP-30 rated enclosure
### 9. Additional Information
Warranty: 5 years limited warranty
Support:
- Technical support via ORing Industrial Networking Corp.
- Email: support@oring-networking.com
- Website: [www.oring-networking.com](http://www.oring-networking.com)
- Tel: +886-2-2218-1066 | Fax: +886-2-2218-1014
Maintenance:
- Periodic inspection of connectors and power terminals recommended.
- Ensure fiber connectors are clean and dust-free.
- Verify LED indicators regularly for link and power status.
Firmware & Updates:
- Hardware-based device; no firmware updates required for standard operation.
- Configuration via DIP-switches only (no software interface).
Ordering Information:
- IMC-P111FX-MM-SC-M12-LV: Multi-mode, 2 km, 1310 nm, SC connector, LV power
- IMC-P111FX-SS-SC-M12-LV: Single-mode, 30 km, 1310 nm, SC connector, LV power *(this model)*
- IMC-P111FX-MM/SS-SC-M12-HV_xx: High-voltage variants with regional power cords (US, UK, EU, JP)
- IMC-P111P-M12-LV/HV: SFP socket variants for flexible fiber modules
### Summary
The ORing IMC-P111FX-SS-SC-M12-LV is a high-reliability, industrial-grade Ethernet-to-fiber media converter engineered for demanding environments such as power substations and railway systems. It provides robust connectivity between copper and fiber networks, ensuring long-distance, interference-free communication. With compliance to IEC 61850-3, IEEE 1613, and EN50155 standards, it guarantees performance under extreme conditions.
Its rugged IP-30 enclosure, M12 connectors, wide temperature tolerance, and redundant power inputs make it ideal for mission-critical applications requiring continuous uptime. The integrated LFP function, configurable DIP-switches, and relay alarm output enhance operational reliability and simplify maintenance.
This model’s single-mode SC fiber port supports up to 30 km transmission, making it suitable for extended network backbones in industrial automation, transportation, and energy sectors. With a 5-year warranty and ORing’s proven industrial networking expertise, the IMC-P111FX-SS-SC-M12-LV delivers dependable, long-term performance in the harshest environments.
-
DataSheet_IMC-P111FX_IMC-P111P-M12_Series.pdf
PDF Catalog
-
QIG_IMC-P111-M12 Series.pdf
Manual
No accessories available.