- Three Independent RTD Input Channels: Supports simultaneous measurement from up to three RTD sensors, enabling multi-point temperature monitoring.
- CAN-Bus Communication Interface: Fully compliant with the CAN 2.0A/B standard, allowing integration into existing CAN-based control systems.
- High Accuracy and Stability: Designed for precise temperature measurement with low drift and high linearity across a wide temperature range.
- Wide RTD Compatibility: Supports standard RTD types such as Pt100, Pt200, Pt500, and Pt1000, with configurable wiring options (2-, 3-, or 4-wire connections).
- Industrial-Grade Design: Rugged enclosure and wide operating temperature range suitable for harsh industrial environments.
- Isolation Protection: Channel-to-channel and channel-to-system isolation to prevent ground loops and electrical interference.
- Configurable Sampling Rate: Adjustable data acquisition rate to balance between response time and measurement resolution.
- Plug-and-Play Integration: Compatible with ADLINK’s NuDAM configuration tools and CANopen protocol for easy setup and network management.
- LED Indicators: Status LEDs for power, communication, and channel activity monitoring.
- DIN-Rail Mountable: Compact form factor with DIN-rail mounting for easy installation in control cabinets.
- CAN-Bus Communication Interface: Fully compliant with the CAN 2.0A/B standard, allowing integration into existing CAN-based control systems.
- High Accuracy and Stability: Designed for precise temperature measurement with low drift and high linearity across a wide temperature range.
- Wide RTD Compatibility: Supports standard RTD types such as Pt100, Pt200, Pt500, and Pt1000, with configurable wiring options (2-, 3-, or 4-wire connections).
- Industrial-Grade Design: Rugged enclosure and wide operating temperature range suitable for harsh industrial environments.
- Isolation Protection: Channel-to-channel and channel-to-system isolation to prevent ground loops and electrical interference.
- Configurable Sampling Rate: Adjustable data acquisition rate to balance between response time and measurement resolution.
- Plug-and-Play Integration: Compatible with ADLINK’s NuDAM configuration tools and CANopen protocol for easy setup and network management.
- LED Indicators: Status LEDs for power, communication, and channel activity monitoring.
- DIN-Rail Mountable: Compact form factor with DIN-rail mounting for easy installation in control cabinets.
1. Product Overview
Product Name: NuDAM CAN-Bus 3-Channel RTD Input Module
Model Number: ND-7013
Article Number: ND-7013
Series: NuDAM Distributed Data Acquisition and Control Modules
Manufacturer: ADLINK Technology Inc.
The ADLINK NuDAM ND-7013 is a high-performance, industrial-grade CAN-Bus-based remote data acquisition module designed for precise temperature measurement using RTD (Resistance Temperature Detector) sensors. As part of ADLINK’s NuDAM series, the ND-7013 provides reliable, distributed temperature monitoring and control capabilities for industrial automation, process control, and environmental monitoring systems. It integrates seamlessly into CAN-Bus networks, offering robust communication, high accuracy, and flexible configuration options for multi-channel RTD input applications.
2. Key Features
- Three Independent RTD Input Channels: Supports simultaneous measurement from up to three RTD sensors, enabling multi-point temperature monitoring.
- CAN-Bus Communication Interface: Fully compliant with the CAN 2.0A/B standard, allowing integration into existing CAN-based control systems.
- High Accuracy and Stability: Designed for precise temperature measurement with low drift and high linearity across a wide temperature range.
- Wide RTD Compatibility: Supports standard RTD types such as Pt100, Pt200, Pt500, and Pt1000, with configurable wiring options (2-, 3-, or 4-wire connections).
- Industrial-Grade Design: Rugged enclosure and wide operating temperature range suitable for harsh industrial environments.
- Isolation Protection: Channel-to-channel and channel-to-system isolation to prevent ground loops and electrical interference.
- Configurable Sampling Rate: Adjustable data acquisition rate to balance between response time and measurement resolution.
- Plug-and-Play Integration: Compatible with ADLINK’s NuDAM configuration tools and CANopen protocol for easy setup and network management.
- LED Indicators: Status LEDs for power, communication, and channel activity monitoring.
- DIN-Rail Mountable: Compact form factor with DIN-rail mounting for easy installation in control cabinets.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | ND-7013 |
| Input Channels | 3 RTD input channels |
| Supported RTD Types | Pt100, Pt200, Pt500, Pt1000 |
| Wiring Configuration | 2-wire, 3-wire, or 4-wire |
| Input Range | -200°C to +850°C (depending on RTD type) |
| Resolution | 16-bit A/D conversion |
| Accuracy | ±0.1% of full scale typical |
| Sampling Rate | Up to 10 samples per second per channel (configurable) |
| Input Impedance | >1 MΩ |
| Isolation Voltage | 3000 VDC channel-to-system isolation |
| Communication Interface | CAN-Bus (CAN 2.0A/B compatible) |
| Baud Rate | 10 kbps to 1 Mbps (software selectable) |
| Protocol Support | CANopen, NuDAM proprietary protocol |
| Power Supply | 10–30 VDC |
| Power Consumption | < 2 W typical |
| Operating Temperature | -25°C to +75°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 10–90% RH, non-condensing |
| Dimensions (W × H × D) | Approx. 72 mm × 118 mm × 42 mm |
| Weight | Approx. 250 g |
| Enclosure Material | Industrial-grade ABS with metal shielding |
| Mounting | DIN-rail or wall mount |
| LED Indicators | Power, CAN status, channel activity |
4. Functionality
The ND-7013 functions as a remote temperature measurement module that interfaces directly with RTD sensors and transmits temperature data over a CAN-Bus network. Each of its three input channels can independently measure temperature from a connected RTD sensor. The module converts the analog resistance signal from the RTD into a digital temperature value using a high-resolution 16-bit A/D converter.
The digital data is then transmitted via the CAN-Bus interface to a host controller, PLC, or SCADA system. The ND-7013 supports both CANopen and NuDAM proprietary communication protocols, allowing flexible integration into various industrial control architectures.
Use Cases and Applications:
- Industrial process temperature monitoring and control
- Factory automation and machine temperature supervision
- Environmental and laboratory temperature data logging
- HVAC and building management systems
- Energy management and power plant monitoring
- Food and pharmaceutical process validation
Compatibility:
The ND-7013 is compatible with ADLINK’s NuDAM configuration software, CANopen master devices, and third-party CAN-Bus controllers. It can be integrated into distributed control systems (DCS), programmable logic controllers (PLCs), or PC-based data acquisition systems.
5. Components & Accessories
Included Items:
- ND-7013 CAN-Bus 3-Channel RTD Input Module
- Quick Start Guide / User Manual
- Terminal block connectors for RTD input and power supply
- DIN-rail mounting clip
Optional Accessories:
- CAN-Bus communication cables (shielded twisted pair)
- CAN-Bus terminators (120 Ω)
- External power supply (24 VDC recommended)
- Configuration software (NuDAM Utility or CANopen configuration tool)
- Protective enclosure or panel mounting kit
Connectors:
- RTD Input Terminals: Screw-type removable terminal blocks for secure sensor wiring
- Power Connector: 2-pin terminal block (10–30 VDC input)
- CAN-Bus Connector: 3-pin terminal block (CAN_H, CAN_L, GND)
6. Installation & Setup
Requirements:
- Power supply: 10–30 VDC regulated
- CAN-Bus network with proper termination (120 Ω at both ends)
- Compatible RTD sensors (Pt100, Pt200, Pt500, Pt1000)
- Host controller or PC with CAN interface
Mounting Options:
- DIN-Rail Mounting: Standard 35 mm DIN-rail clip for quick installation in control panels.
- Wall Mounting: Optional brackets for fixed installation on flat surfaces.
Configuration Steps:
1. Hardware Connection: Connect RTD sensors to the input terminals according to the wiring diagram (2-, 3-, or 4-wire).
2. Power Connection: Supply 10–30 VDC to the power terminals.
3. CAN-Bus Connection: Connect CAN_H, CAN_L, and GND to the network bus.
4. Network Configuration: Set the CAN node ID and baud rate using DIP switches or configuration software.
5. Software Setup: Use ADLINK’s NuDAM Utility or a CANopen configuration tool to define channel parameters, scaling, and data acquisition settings.
6. Verification: Check LED indicators for power and communication status; verify data acquisition through the host system.
Safety Considerations:
- Ensure proper grounding and shielding to minimize noise.
- Avoid wiring changes while the module is powered.
- Maintain correct polarity for power and signal connections.
7. Performance & Capabilities
The ND-7013 delivers high-precision temperature measurement with excellent linearity and stability. Its 16-bit resolution ensures fine temperature granularity, while the isolated input design minimizes interference and cross-talk between channels.
Speed and Capacity:
- Up to 10 samples per second per channel, suitable for real-time monitoring.
- Three simultaneous measurement channels for multi-point sensing.
Efficiency:
- Low power consumption (<2 W) allows for energy-efficient operation in distributed systems.
- CAN-Bus communication ensures deterministic data transfer with minimal latency.
Limitations:
- Designed specifically for RTD sensors; not compatible with thermocouples or voltage/current inputs.
- Sampling rate may be reduced when all channels are active simultaneously.
- Requires proper CAN-Bus termination and configuration for optimal performance.
Reliability:
- Industrial-grade components ensure long-term stability and minimal drift.
- Isolation and surge protection enhance durability in electrically noisy environments.
8. Standards & Compliance
The ND-7013 complies with major industrial and communication standards to ensure interoperability and safety:
- CAN-Bus Standard: ISO 11898-2 compliant (CAN 2.0A/B)
- Protocol Support: CANopen DS-301 and NuDAM proprietary protocol
- Electrical Safety: CE certified for electromagnetic compatibility and low-voltage directives
- RoHS Compliance: Conforms to Restriction of Hazardous Substances Directive
- EMC Immunity: Designed to meet EN 61000-6-2 (industrial immunity) and EN 61000-6-4 (industrial emissions)
- Isolation Protection: 3000 VDC isolation between channels and system
- Environmental Compliance: Meets industrial temperature and humidity standards
These certifications ensure that the ND-7013 can be deployed in regulated industrial environments and integrated into systems requiring compliance with international safety and communication standards.
9. Additional Information
Warranty:
ADLINK provides a 2-year limited warranty covering defects in materials and workmanship under normal operating conditions.
Technical Support:
Comprehensive technical support is available through ADLINK’s global service network, including online documentation, configuration utilities, and firmware updates.
Maintenance:
- Periodic inspection of wiring and connectors is recommended.
- Keep the module free from dust and moisture.
- Firmware updates can be applied via CAN-Bus using ADLINK’s configuration tools.
Software & Firmware Updates:
- Firmware upgrades available through ADLINK’s support portal.
- Configuration software supports Windows-based systems for parameter setup and diagnostics.
Service & Replacement:
- Field-replaceable terminal blocks and mounting accessories.
- RMA (Return Merchandise Authorization) process available for defective units.
Lifecycle & Availability:
- Long-term product availability guaranteed under ADLINK’s industrial product lifecycle policy.
- Backward compatibility with previous NuDAM series modules ensures easy system expansion.
### Summary
The ADLINK NuDAM ND-7013 CAN-Bus 3-Channel RTD Input Module is a robust, high-accuracy data acquisition device engineered for distributed temperature measurement in industrial environments. With support for multiple RTD types, isolated inputs, and flexible CAN-Bus communication, it provides a reliable solution for temperature monitoring and control applications. Its compact, DIN-rail mountable design, wide operating temperature range, and compliance with industrial standards make it ideal for integration into automation systems, process control networks, and environmental monitoring setups.
The ND-7013 exemplifies ADLINK’s commitment to precision, reliability, and interoperability in industrial data acquisition technology.
Product Name: NuDAM CAN-Bus 3-Channel RTD Input Module
Model Number: ND-7013
Article Number: ND-7013
Series: NuDAM Distributed Data Acquisition and Control Modules
Manufacturer: ADLINK Technology Inc.
The ADLINK NuDAM ND-7013 is a high-performance, industrial-grade CAN-Bus-based remote data acquisition module designed for precise temperature measurement using RTD (Resistance Temperature Detector) sensors. As part of ADLINK’s NuDAM series, the ND-7013 provides reliable, distributed temperature monitoring and control capabilities for industrial automation, process control, and environmental monitoring systems. It integrates seamlessly into CAN-Bus networks, offering robust communication, high accuracy, and flexible configuration options for multi-channel RTD input applications.
2. Key Features
- Three Independent RTD Input Channels: Supports simultaneous measurement from up to three RTD sensors, enabling multi-point temperature monitoring.
- CAN-Bus Communication Interface: Fully compliant with the CAN 2.0A/B standard, allowing integration into existing CAN-based control systems.
- High Accuracy and Stability: Designed for precise temperature measurement with low drift and high linearity across a wide temperature range.
- Wide RTD Compatibility: Supports standard RTD types such as Pt100, Pt200, Pt500, and Pt1000, with configurable wiring options (2-, 3-, or 4-wire connections).
- Industrial-Grade Design: Rugged enclosure and wide operating temperature range suitable for harsh industrial environments.
- Isolation Protection: Channel-to-channel and channel-to-system isolation to prevent ground loops and electrical interference.
- Configurable Sampling Rate: Adjustable data acquisition rate to balance between response time and measurement resolution.
- Plug-and-Play Integration: Compatible with ADLINK’s NuDAM configuration tools and CANopen protocol for easy setup and network management.
- LED Indicators: Status LEDs for power, communication, and channel activity monitoring.
- DIN-Rail Mountable: Compact form factor with DIN-rail mounting for easy installation in control cabinets.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | ND-7013 |
| Input Channels | 3 RTD input channels |
| Supported RTD Types | Pt100, Pt200, Pt500, Pt1000 |
| Wiring Configuration | 2-wire, 3-wire, or 4-wire |
| Input Range | -200°C to +850°C (depending on RTD type) |
| Resolution | 16-bit A/D conversion |
| Accuracy | ±0.1% of full scale typical |
| Sampling Rate | Up to 10 samples per second per channel (configurable) |
| Input Impedance | >1 MΩ |
| Isolation Voltage | 3000 VDC channel-to-system isolation |
| Communication Interface | CAN-Bus (CAN 2.0A/B compatible) |
| Baud Rate | 10 kbps to 1 Mbps (software selectable) |
| Protocol Support | CANopen, NuDAM proprietary protocol |
| Power Supply | 10–30 VDC |
| Power Consumption | < 2 W typical |
| Operating Temperature | -25°C to +75°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 10–90% RH, non-condensing |
| Dimensions (W × H × D) | Approx. 72 mm × 118 mm × 42 mm |
| Weight | Approx. 250 g |
| Enclosure Material | Industrial-grade ABS with metal shielding |
| Mounting | DIN-rail or wall mount |
| LED Indicators | Power, CAN status, channel activity |
4. Functionality
The ND-7013 functions as a remote temperature measurement module that interfaces directly with RTD sensors and transmits temperature data over a CAN-Bus network. Each of its three input channels can independently measure temperature from a connected RTD sensor. The module converts the analog resistance signal from the RTD into a digital temperature value using a high-resolution 16-bit A/D converter.
The digital data is then transmitted via the CAN-Bus interface to a host controller, PLC, or SCADA system. The ND-7013 supports both CANopen and NuDAM proprietary communication protocols, allowing flexible integration into various industrial control architectures.
Use Cases and Applications:
- Industrial process temperature monitoring and control
- Factory automation and machine temperature supervision
- Environmental and laboratory temperature data logging
- HVAC and building management systems
- Energy management and power plant monitoring
- Food and pharmaceutical process validation
Compatibility:
The ND-7013 is compatible with ADLINK’s NuDAM configuration software, CANopen master devices, and third-party CAN-Bus controllers. It can be integrated into distributed control systems (DCS), programmable logic controllers (PLCs), or PC-based data acquisition systems.
5. Components & Accessories
Included Items:
- ND-7013 CAN-Bus 3-Channel RTD Input Module
- Quick Start Guide / User Manual
- Terminal block connectors for RTD input and power supply
- DIN-rail mounting clip
Optional Accessories:
- CAN-Bus communication cables (shielded twisted pair)
- CAN-Bus terminators (120 Ω)
- External power supply (24 VDC recommended)
- Configuration software (NuDAM Utility or CANopen configuration tool)
- Protective enclosure or panel mounting kit
Connectors:
- RTD Input Terminals: Screw-type removable terminal blocks for secure sensor wiring
- Power Connector: 2-pin terminal block (10–30 VDC input)
- CAN-Bus Connector: 3-pin terminal block (CAN_H, CAN_L, GND)
6. Installation & Setup
Requirements:
- Power supply: 10–30 VDC regulated
- CAN-Bus network with proper termination (120 Ω at both ends)
- Compatible RTD sensors (Pt100, Pt200, Pt500, Pt1000)
- Host controller or PC with CAN interface
Mounting Options:
- DIN-Rail Mounting: Standard 35 mm DIN-rail clip for quick installation in control panels.
- Wall Mounting: Optional brackets for fixed installation on flat surfaces.
Configuration Steps:
1. Hardware Connection: Connect RTD sensors to the input terminals according to the wiring diagram (2-, 3-, or 4-wire).
2. Power Connection: Supply 10–30 VDC to the power terminals.
3. CAN-Bus Connection: Connect CAN_H, CAN_L, and GND to the network bus.
4. Network Configuration: Set the CAN node ID and baud rate using DIP switches or configuration software.
5. Software Setup: Use ADLINK’s NuDAM Utility or a CANopen configuration tool to define channel parameters, scaling, and data acquisition settings.
6. Verification: Check LED indicators for power and communication status; verify data acquisition through the host system.
Safety Considerations:
- Ensure proper grounding and shielding to minimize noise.
- Avoid wiring changes while the module is powered.
- Maintain correct polarity for power and signal connections.
7. Performance & Capabilities
The ND-7013 delivers high-precision temperature measurement with excellent linearity and stability. Its 16-bit resolution ensures fine temperature granularity, while the isolated input design minimizes interference and cross-talk between channels.
Speed and Capacity:
- Up to 10 samples per second per channel, suitable for real-time monitoring.
- Three simultaneous measurement channels for multi-point sensing.
Efficiency:
- Low power consumption (<2 W) allows for energy-efficient operation in distributed systems.
- CAN-Bus communication ensures deterministic data transfer with minimal latency.
Limitations:
- Designed specifically for RTD sensors; not compatible with thermocouples or voltage/current inputs.
- Sampling rate may be reduced when all channels are active simultaneously.
- Requires proper CAN-Bus termination and configuration for optimal performance.
Reliability:
- Industrial-grade components ensure long-term stability and minimal drift.
- Isolation and surge protection enhance durability in electrically noisy environments.
8. Standards & Compliance
The ND-7013 complies with major industrial and communication standards to ensure interoperability and safety:
- CAN-Bus Standard: ISO 11898-2 compliant (CAN 2.0A/B)
- Protocol Support: CANopen DS-301 and NuDAM proprietary protocol
- Electrical Safety: CE certified for electromagnetic compatibility and low-voltage directives
- RoHS Compliance: Conforms to Restriction of Hazardous Substances Directive
- EMC Immunity: Designed to meet EN 61000-6-2 (industrial immunity) and EN 61000-6-4 (industrial emissions)
- Isolation Protection: 3000 VDC isolation between channels and system
- Environmental Compliance: Meets industrial temperature and humidity standards
These certifications ensure that the ND-7013 can be deployed in regulated industrial environments and integrated into systems requiring compliance with international safety and communication standards.
9. Additional Information
Warranty:
ADLINK provides a 2-year limited warranty covering defects in materials and workmanship under normal operating conditions.
Technical Support:
Comprehensive technical support is available through ADLINK’s global service network, including online documentation, configuration utilities, and firmware updates.
Maintenance:
- Periodic inspection of wiring and connectors is recommended.
- Keep the module free from dust and moisture.
- Firmware updates can be applied via CAN-Bus using ADLINK’s configuration tools.
Software & Firmware Updates:
- Firmware upgrades available through ADLINK’s support portal.
- Configuration software supports Windows-based systems for parameter setup and diagnostics.
Service & Replacement:
- Field-replaceable terminal blocks and mounting accessories.
- RMA (Return Merchandise Authorization) process available for defective units.
Lifecycle & Availability:
- Long-term product availability guaranteed under ADLINK’s industrial product lifecycle policy.
- Backward compatibility with previous NuDAM series modules ensures easy system expansion.
### Summary
The ADLINK NuDAM ND-7013 CAN-Bus 3-Channel RTD Input Module is a robust, high-accuracy data acquisition device engineered for distributed temperature measurement in industrial environments. With support for multiple RTD types, isolated inputs, and flexible CAN-Bus communication, it provides a reliable solution for temperature monitoring and control applications. Its compact, DIN-rail mountable design, wide operating temperature range, and compliance with industrial standards make it ideal for integration into automation systems, process control networks, and environmental monitoring setups.
The ND-7013 exemplifies ADLINK’s commitment to precision, reliability, and interoperability in industrial data acquisition technology.
No manuals/catalogs available.