LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- PXI / CompactPCI 3U Form Factor: Fully compliant with PXI and CompactPCI 3U mechanical and electrical specifications, ensuring compatibility with standard PXI chassis and controllers.
- 16-Channel Scan/Multiplexer Configuration: Provides 16 independent Form A relay channels for flexible signal routing and multiplexing operations.
- Form A Relays: Utilizes Form A (normally open, single-pole single-throw) electromechanical relays for reliable switching of analog and digital signals.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, enabling accurate signal transmission for a wide range of analog and mixed-signal applications.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 Hot Swap specification, allowing safe insertion and removal of the module without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying integration and reducing setup time.
- High Power Handling: Rated for 30 W, 125 VAC, 30 VDC, and 0.5 A maximum switching capacity per channel, suitable for moderate power signal routing.
- Compact and Robust Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring secure electrical connections and mechanical stability.
- PXI Trigger and Synchronization Support: Compatible with PXI trigger bus and timing features for synchronized operation with other PXI modules.
- Industrial-Grade Reliability: Designed for continuous operation in demanding test environments with long relay life and stable performance.
- 16-Channel Scan/Multiplexer Configuration: Provides 16 independent Form A relay channels for flexible signal routing and multiplexing operations.
- Form A Relays: Utilizes Form A (normally open, single-pole single-throw) electromechanical relays for reliable switching of analog and digital signals.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, enabling accurate signal transmission for a wide range of analog and mixed-signal applications.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 Hot Swap specification, allowing safe insertion and removal of the module without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying integration and reducing setup time.
- High Power Handling: Rated for 30 W, 125 VAC, 30 VDC, and 0.5 A maximum switching capacity per channel, suitable for moderate power signal routing.
- Compact and Robust Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring secure electrical connections and mechanical stability.
- PXI Trigger and Synchronization Support: Compatible with PXI trigger bus and timing features for synchronized operation with other PXI modules.
- Industrial-Grade Reliability: Designed for continuous operation in demanding test environments with long relay life and stable performance.
1. Product Overview
Product Name: PXI-7613
Model Number: PXI-7613
Series: PXI / CompactPCI (cPCI) 3U Switching and Multiplexing Series
Article Number: PXI-7613
Manufacturer: ADLINK Technology Inc.
The ADLINK PXI-7613 is a high-performance PXI/cPCI 3U 16-channel Scan/Multiplexer (Scan/MUX) Form A Relay Card designed for automated test and measurement systems requiring flexible signal routing, high reliability, and compliance with PXI and CompactPCI standards. It integrates seamlessly into PXI-based modular instrumentation platforms, providing a robust and scalable switching solution for signal scanning, multiplexing, and routing applications.
2. Key Features
- PXI / CompactPCI 3U Form Factor: Fully compliant with PXI and CompactPCI 3U mechanical and electrical specifications, ensuring compatibility with standard PXI chassis and controllers.
- 16-Channel Scan/Multiplexer Configuration: Provides 16 independent Form A relay channels for flexible signal routing and multiplexing operations.
- Form A Relays: Utilizes Form A (normally open, single-pole single-throw) electromechanical relays for reliable switching of analog and digital signals.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, enabling accurate signal transmission for a wide range of analog and mixed-signal applications.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 Hot Swap specification, allowing safe insertion and removal of the module without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying integration and reducing setup time.
- High Power Handling: Rated for 30 W, 125 VAC, 30 VDC, and 0.5 A maximum switching capacity per channel, suitable for moderate power signal routing.
- Compact and Robust Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring secure electrical connections and mechanical stability.
- PXI Trigger and Synchronization Support: Compatible with PXI trigger bus and timing features for synchronized operation with other PXI modules.
- Industrial-Grade Reliability: Designed for continuous operation in demanding test environments with long relay life and stable performance.
3. Technical Specifications
- Bus Interface: PXI / CompactPCI 3U
- Form Factor: 3U (100 mm x 160 mm)
- Connector Type: 160-pin, 2 mm pitch CompactPCI connector
- Relay Type: Form A (SPST-NO) electromechanical relays
- Number of Channels: 16 independent channels
- Switch Configuration: 16-channel Scan/Multiplexer (Scan/MUX)
- Bandwidth: 10 MHz (-3 dB point)
- Maximum Switching Power: 30 W
- Maximum Switching Voltage: 125 VAC / 30 VDC
- Maximum Switching Current: 0.5 A
- Isolation: Channel-to-channel and channel-to-ground isolation provided by mechanical relays
- Compliance: PICMG 2.1 R1.0 Hot Swap compliant
- Dimensions: 100 mm (height) x 160 mm (depth)
- Weight: Approximately 300–400 g (typical for 3U PXI cards; exact weight may vary)
- Operating Temperature Range: Typically 0°C to +55°C (standard PXI operating range)
- Storage Temperature Range: -20°C to +70°C
- Humidity: 10% to 90% non-condensing
- Cooling Requirements: Convection cooling via PXI chassis airflow
- Power Requirements: Supplied through PXI backplane (typical +5 V and +12 V rails)
4. Functionality
The PXI-7613 functions as a 16-channel scanning and multiplexing relay card, enabling users to connect multiple input signals to a single measurement device or route signals between instruments and units under test (UUTs). Each channel is controlled independently, allowing flexible configuration for scanning, multiplexing, or switching operations.
Operating Principle:
- Each of the 16 Form A relays can connect or disconnect a signal path under software control.
- The relays are actuated via PXI control commands, enabling automated switching sequences.
- The card supports both single-ended and differential signal routing, depending on system configuration.
- The 10 MHz bandwidth ensures minimal signal degradation for analog signals within the specified frequency range.
Use Cases and Applications:
- Automated Test Equipment (ATE) systems
- Signal routing and multiplexing in measurement setups
- Functional testing of electronic components and assemblies
- Data acquisition systems requiring channel scanning
- Switching of analog or low-frequency digital signals
- Laboratory instrumentation and R&D environments
- Integration with PXI-based DAQ, DMM, or oscilloscope modules
Compatibility:
- Compatible with PXI and CompactPCI 3U chassis from ADLINK and other vendors
- Works with PXI controllers and software environments supporting VISA, IVI, or proprietary ADLINK drivers
- Integrates with LabVIEW™, MATLAB®, and other test automation frameworks
5. Components & Accessories
Included Items:
- PXI-7613 16-Channel Scan/MUX Form A Relay Card
- User documentation and quick start guide
- Software drivers and configuration utilities (downloadable from ADLINK support site)
Optional Accessories:
- Shielded cable assemblies for signal connection
- Terminal blocks or breakout modules for easy wiring
- PXI chassis and controller (sold separately)
- Relay replacement kits (for maintenance)
Connectors:
- Front Panel Connector: 160-pin 2 mm CompactPCI connector for signal I/O
- Backplane Interface: PXI bus connector for power, control, and communication
6. Installation & Setup
Requirements:
- PXI or CompactPCI 3U chassis with available slot
- Compatible PXI controller or embedded PC
- Supported operating system (Windows or Linux) with ADLINK driver package
Installation Steps:
1. Power off the PXI chassis (if not using hot-swap).
2. Insert the PXI-7613 module into an available 3U slot, aligning the 160-pin connector with the backplane.
3. Secure the module using the front panel screws.
4. Power on the chassis; the module will be automatically detected (Plug and Play).
5. Install the ADLINK driver and software utilities.
6. Configure the relay channels using the provided software or through PXI control commands.
Mounting Options:
- Standard PXI 3U slot mounting
- Hot-swap insertion/removal supported per PICMG 2.1 R1.0
Configuration:
- Software-controlled relay activation
- Channel grouping and scanning sequences programmable via API
- Integration with test scripts or automation software
7. Performance & Capabilities
Switching Speed:
- Typical relay operate time: 5–10 ms (depending on relay type)
- Release time: 3–5 ms
Signal Integrity:
- 10 MHz (-3 dB) bandwidth ensures low insertion loss and minimal crosstalk for analog signals
- Mechanical relays provide excellent isolation and low leakage currents
Capacity and Efficiency:
- 16 channels allow simultaneous or sequential scanning of multiple signals
- Efficient use of PXI slot space with high channel density
- Low power consumption due to electromechanical relay design
Limitations:
- Not suitable for high-frequency RF switching beyond 10 MHz
- Limited to 0.5 A per channel; not intended for high-current power switching
- Relay lifetime subject to mechanical wear (typically >10⁶ operations)
Reliability:
- Industrial-grade relays ensure long operational life
- Designed for continuous operation in automated test environments
8. Standards & Compliance
- PXI Standard Compliance: Fully compliant with PXI specifications for mechanical, electrical, and software interfaces
- CompactPCI Compliance: Conforms to CompactPCI 3U form factor and electrical standards
- Hot Swap Compliance: PICMG 2.1 R1.0 compliant for safe insertion/removal under power
- Safety and EMC: Designed to meet applicable CE and FCC requirements (EN 61326, EN 61010-1)
- RoHS Compliance: Manufactured in accordance with RoHS directives for hazardous substance reduction
- Quality Assurance: Produced under ISO 9001-certified manufacturing processes
9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 1–3 years, depending on region and distributor)
- Covers defects in materials and workmanship under normal operating conditions
Support:
- Technical support available through ADLINK’s global service network
- Online resources including manuals, driver downloads, and FAQs
- Firmware and driver updates provided via ADLINK support portal
Maintenance:
- Periodic relay inspection recommended for high-duty-cycle applications
- Replacement relays available as service parts
- No user-serviceable internal components beyond relay replacement
Software & Updates:
- Compatible with ADLINK’s PXI driver suite and software development kits (SDKs)
- Supports major test automation environments (LabVIEW™, LabWindows™/CVI, MATLAB®, C/C++, Python)
- Regular driver and firmware updates ensure compatibility with new PXI controllers and OS versions
Lifecycle & Availability:
- Long-term availability supported for industrial and OEM customers
- Backward compatibility with existing PXI systems ensures investment protection
### Summary
The ADLINK PXI-7613 PXI/cPCI 3U 16-Channel Scan/Multiplexer Form A Relay Card is a versatile, high-reliability switching module engineered for automated test and measurement systems. With its 16 Form A relays, 10 MHz bandwidth, and compliance with PXI and CompactPCI standards, it provides a robust solution for signal routing, scanning, and multiplexing tasks. Its hot-swappable design, plug-and-play integration, and industrial-grade construction make it ideal for laboratory, production, and field test environments.
Offering a balance of performance, flexibility, and reliability, the PXI-7613 is a key component for engineers and system integrators seeking a dependable PXI switching solution that meets stringent technical and operational requirements.
Product Name: PXI-7613
Model Number: PXI-7613
Series: PXI / CompactPCI (cPCI) 3U Switching and Multiplexing Series
Article Number: PXI-7613
Manufacturer: ADLINK Technology Inc.
The ADLINK PXI-7613 is a high-performance PXI/cPCI 3U 16-channel Scan/Multiplexer (Scan/MUX) Form A Relay Card designed for automated test and measurement systems requiring flexible signal routing, high reliability, and compliance with PXI and CompactPCI standards. It integrates seamlessly into PXI-based modular instrumentation platforms, providing a robust and scalable switching solution for signal scanning, multiplexing, and routing applications.
2. Key Features
- PXI / CompactPCI 3U Form Factor: Fully compliant with PXI and CompactPCI 3U mechanical and electrical specifications, ensuring compatibility with standard PXI chassis and controllers.
- 16-Channel Scan/Multiplexer Configuration: Provides 16 independent Form A relay channels for flexible signal routing and multiplexing operations.
- Form A Relays: Utilizes Form A (normally open, single-pole single-throw) electromechanical relays for reliable switching of analog and digital signals.
- High Bandwidth Performance: Offers a 10 MHz (-3 dB) bandwidth, enabling accurate signal transmission for a wide range of analog and mixed-signal applications.
- Hot-Swappable Design: Compliant with PICMG 2.1 R1.0 Hot Swap specification, allowing safe insertion and removal of the module without powering down the PXI chassis.
- Plug and Play Operation: Supports automatic detection and configuration within PXI systems, simplifying integration and reducing setup time.
- High Power Handling: Rated for 30 W, 125 VAC, 30 VDC, and 0.5 A maximum switching capacity per channel, suitable for moderate power signal routing.
- Compact and Robust Construction: Built on a 100 mm x 160 mm PCB with a 160-pin 2 mm connector, ensuring secure electrical connections and mechanical stability.
- PXI Trigger and Synchronization Support: Compatible with PXI trigger bus and timing features for synchronized operation with other PXI modules.
- Industrial-Grade Reliability: Designed for continuous operation in demanding test environments with long relay life and stable performance.
3. Technical Specifications
- Bus Interface: PXI / CompactPCI 3U
- Form Factor: 3U (100 mm x 160 mm)
- Connector Type: 160-pin, 2 mm pitch CompactPCI connector
- Relay Type: Form A (SPST-NO) electromechanical relays
- Number of Channels: 16 independent channels
- Switch Configuration: 16-channel Scan/Multiplexer (Scan/MUX)
- Bandwidth: 10 MHz (-3 dB point)
- Maximum Switching Power: 30 W
- Maximum Switching Voltage: 125 VAC / 30 VDC
- Maximum Switching Current: 0.5 A
- Isolation: Channel-to-channel and channel-to-ground isolation provided by mechanical relays
- Compliance: PICMG 2.1 R1.0 Hot Swap compliant
- Dimensions: 100 mm (height) x 160 mm (depth)
- Weight: Approximately 300–400 g (typical for 3U PXI cards; exact weight may vary)
- Operating Temperature Range: Typically 0°C to +55°C (standard PXI operating range)
- Storage Temperature Range: -20°C to +70°C
- Humidity: 10% to 90% non-condensing
- Cooling Requirements: Convection cooling via PXI chassis airflow
- Power Requirements: Supplied through PXI backplane (typical +5 V and +12 V rails)
4. Functionality
The PXI-7613 functions as a 16-channel scanning and multiplexing relay card, enabling users to connect multiple input signals to a single measurement device or route signals between instruments and units under test (UUTs). Each channel is controlled independently, allowing flexible configuration for scanning, multiplexing, or switching operations.
Operating Principle:
- Each of the 16 Form A relays can connect or disconnect a signal path under software control.
- The relays are actuated via PXI control commands, enabling automated switching sequences.
- The card supports both single-ended and differential signal routing, depending on system configuration.
- The 10 MHz bandwidth ensures minimal signal degradation for analog signals within the specified frequency range.
Use Cases and Applications:
- Automated Test Equipment (ATE) systems
- Signal routing and multiplexing in measurement setups
- Functional testing of electronic components and assemblies
- Data acquisition systems requiring channel scanning
- Switching of analog or low-frequency digital signals
- Laboratory instrumentation and R&D environments
- Integration with PXI-based DAQ, DMM, or oscilloscope modules
Compatibility:
- Compatible with PXI and CompactPCI 3U chassis from ADLINK and other vendors
- Works with PXI controllers and software environments supporting VISA, IVI, or proprietary ADLINK drivers
- Integrates with LabVIEW™, MATLAB®, and other test automation frameworks
5. Components & Accessories
Included Items:
- PXI-7613 16-Channel Scan/MUX Form A Relay Card
- User documentation and quick start guide
- Software drivers and configuration utilities (downloadable from ADLINK support site)
Optional Accessories:
- Shielded cable assemblies for signal connection
- Terminal blocks or breakout modules for easy wiring
- PXI chassis and controller (sold separately)
- Relay replacement kits (for maintenance)
Connectors:
- Front Panel Connector: 160-pin 2 mm CompactPCI connector for signal I/O
- Backplane Interface: PXI bus connector for power, control, and communication
6. Installation & Setup
Requirements:
- PXI or CompactPCI 3U chassis with available slot
- Compatible PXI controller or embedded PC
- Supported operating system (Windows or Linux) with ADLINK driver package
Installation Steps:
1. Power off the PXI chassis (if not using hot-swap).
2. Insert the PXI-7613 module into an available 3U slot, aligning the 160-pin connector with the backplane.
3. Secure the module using the front panel screws.
4. Power on the chassis; the module will be automatically detected (Plug and Play).
5. Install the ADLINK driver and software utilities.
6. Configure the relay channels using the provided software or through PXI control commands.
Mounting Options:
- Standard PXI 3U slot mounting
- Hot-swap insertion/removal supported per PICMG 2.1 R1.0
Configuration:
- Software-controlled relay activation
- Channel grouping and scanning sequences programmable via API
- Integration with test scripts or automation software
7. Performance & Capabilities
Switching Speed:
- Typical relay operate time: 5–10 ms (depending on relay type)
- Release time: 3–5 ms
Signal Integrity:
- 10 MHz (-3 dB) bandwidth ensures low insertion loss and minimal crosstalk for analog signals
- Mechanical relays provide excellent isolation and low leakage currents
Capacity and Efficiency:
- 16 channels allow simultaneous or sequential scanning of multiple signals
- Efficient use of PXI slot space with high channel density
- Low power consumption due to electromechanical relay design
Limitations:
- Not suitable for high-frequency RF switching beyond 10 MHz
- Limited to 0.5 A per channel; not intended for high-current power switching
- Relay lifetime subject to mechanical wear (typically >10⁶ operations)
Reliability:
- Industrial-grade relays ensure long operational life
- Designed for continuous operation in automated test environments
8. Standards & Compliance
- PXI Standard Compliance: Fully compliant with PXI specifications for mechanical, electrical, and software interfaces
- CompactPCI Compliance: Conforms to CompactPCI 3U form factor and electrical standards
- Hot Swap Compliance: PICMG 2.1 R1.0 compliant for safe insertion/removal under power
- Safety and EMC: Designed to meet applicable CE and FCC requirements (EN 61326, EN 61010-1)
- RoHS Compliance: Manufactured in accordance with RoHS directives for hazardous substance reduction
- Quality Assurance: Produced under ISO 9001-certified manufacturing processes
9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 1–3 years, depending on region and distributor)
- Covers defects in materials and workmanship under normal operating conditions
Support:
- Technical support available through ADLINK’s global service network
- Online resources including manuals, driver downloads, and FAQs
- Firmware and driver updates provided via ADLINK support portal
Maintenance:
- Periodic relay inspection recommended for high-duty-cycle applications
- Replacement relays available as service parts
- No user-serviceable internal components beyond relay replacement
Software & Updates:
- Compatible with ADLINK’s PXI driver suite and software development kits (SDKs)
- Supports major test automation environments (LabVIEW™, LabWindows™/CVI, MATLAB®, C/C++, Python)
- Regular driver and firmware updates ensure compatibility with new PXI controllers and OS versions
Lifecycle & Availability:
- Long-term availability supported for industrial and OEM customers
- Backward compatibility with existing PXI systems ensures investment protection
### Summary
The ADLINK PXI-7613 PXI/cPCI 3U 16-Channel Scan/Multiplexer Form A Relay Card is a versatile, high-reliability switching module engineered for automated test and measurement systems. With its 16 Form A relays, 10 MHz bandwidth, and compliance with PXI and CompactPCI standards, it provides a robust solution for signal routing, scanning, and multiplexing tasks. Its hot-swappable design, plug-and-play integration, and industrial-grade construction make it ideal for laboratory, production, and field test environments.
Offering a balance of performance, flexibility, and reliability, the PXI-7613 is a key component for engineers and system integrators seeking a dependable PXI switching solution that meets stringent technical and operational requirements.
No manuals/catalogs available.
No accessories available.