Filter
Unsere Produkte
Seite: 45
1.7.9.2 | INJ-102GT-24V | PoE Power Injector 2*1000TX 2*port@30W IP30 12..36VDCin slim |
145,00 € (ohne MwSt) |
|
1.7.9.2 | INJ-102GT++ | PoE Power Injector 2*1000TX @90W 50VDCin IP30 slim |
160,00 € (ohne MwSt) |
|
1.7.9.2 | INJ-101GT++-60W-24V | PoE Power Injector 1*1000TX @60W IP30 24V |
190,00 € (ohne MwSt) |
|
1.7.9.2 | INJ-101GT++-60W | PoE Power Injector 1*1000TX @60W IP30 |
150,00 € (ohne MwSt) |
|
1.7.9.2 | INJ-102GT++-24V | PoE Power Injector 2*1000TX @90W IP30 24..50VDCin |
225,00 € (ohne MwSt) |
|
4.2.1.3 | TRGPS-9084GT-M12X-BP2-MV | Managed Switch 8*1000TX 8*PoE 4*1000TX M12 PSE M12 EN50155 |
1.712,50 € (ohne MwSt) |
|
4.2.1.3 | TPS-3162GT-M12-BP1-24V | Managed Switch 16*100TX PoE PSE 24V M12 2*GbE Bypass EN50155 | Request a quote | |
4.2.1.3 | TPS-3162GT-M12-BP1 | Managed Switch 16*100TX PoE PSE 50V M12 2*GbE Bypass EN50155 | Request a quote | |
4.2.1.3 | TPS-9168GT-M12 | Managed Switch 8*100TX 8*PoE PSE 50V M12 2*GbE EN50155 | Request a quote | |
4.2.1.3 | TPS-3082GF-MM-M12-QODC | Managed Switch 8*100TX 2x1000-SX 8*PoE PSE M12 48VDC EN50155 | Request a quote | |
4.2.1.3 | TPS-3082GT-M12-BP1-24V | Managed Switch 8*100TX PoE PSE 24V M12 2*GbE Bypass EN50155 | Request a quote | |
4.2.1.3 | TPS-3082GT-M12-BP1 | Managed Switch 8*100TX *PoE PSE 50V M12 2*GbE Bypass EN50155 | Request a quote | |
4.2.1.3 | V2406 Series | Intel® 7th Gen Core™ CPU railway computer | Request a quote | |
4.2.1.3 | TGPS-9164GT-M12X-BP2-MV | EN50155 20-port managed Gigabit PoE Ethernet switch | Request a quote | |
4.2.1.3 | TRGPS-9084GT-M12X-BP2-MV-double | Managed Switch 8*1000TX 8*PoE 4*10000TX M12 PSE M12 EN50155 | Request a quote | |
4.2.1.3 | TGPS-9084GT-M12X-BP2-MV | EN50155 12-port managed Gigabit PoE Ethernet switch | Request a quote | |
4.2.1.3 | TPS-3882GT-M12-BP1-24V | Man.Switch 16*100TX 8*PoE PSE 24V M12 2*GbE Bypass EN50155 | Request a quote | |
4.2.1.3 | TPS-3882GT-M12-BP1 | Man.Switch 16*100TX 8*PoE PSE 50V M12 2*GbE Bypass EN50155 | Request a quote | |
4.2.1.3 | TPS-3044TX-M12 | Managed Switch 8*100TX 4*PoE PSE M12 2*GbE Connector EN50155 | Request a quote | |
4.2.1.3 | TPS-3082GT-M12X-BP1 | Managed Switch 8*100TX 8*PoE M12 2*GbE Bypass EN50155 | Request a quote | |
4.5.3.3 | EDAM-9466 | Ethernet Isolated 6*DI 6*Relay 5A PoE Modbus Module |
216,00 € (ohne MwSt) |
|
4.5.3.3 | EDAM-9066A | Ethernet Isolated 6*DI 6*Relay 5A Modbus Module |
193,00 € (ohne MwSt) |
|
4.5.3.3 | EDAM-9461 | Ethernet Isolated 6*DI 6*Relay PoE Modbus Module |
215,00 € (ohne MwSt) |
|
1.7.9.1 | SPL-101GT++-12V | PoE Splitter 1-Port 60W @12V IP30 Slim Case |
235,00 € (ohne MwSt) |
|
1.7.9.1 | SPL-101GT-12V | PoE Splitter 1-Port 30W @12V IP30 Slim Case |
133,00 € (ohne MwSt) |
|
1.7.9.1 | SPL-101GT | PoE Splitter 1-Port 30W 1,25A@24V IP30 Slim Case |
118,00 € (ohne MwSt) |
|
4.2.1.2 | TGXPS-141GX-M12 | Unmanaged Switch 8*100TX M12 4*PoE PSE 24V 2*bypass EN50155 | Request a quote | |
4.2.1.2 | TPS-141TX-M12-24V | Unmanaged Switch 5*100TX M12 4*PoE PSE 24V EN50155 | EOL, call | |
4.2.1.2 | TXPS-141XT-M12 | Unmanaged Switch 5*100TX M12 4*PoE PSE 50V EN50155 IP40 | Request a quote | |
2.2.7 | PB-2500J | Supercapacitor-based Uninterruptible 2500J (Ws) Power Backup | Request a quote | |
2.2.7 | PB-9250J-SA | Supercapacitor-based Uninterruptible 9250J (Ws) Power Backup | Request a quote | |
2.2.7 | PB-4600J-SA | Supercapacitor-based Uninterruptible 4600J (Ws) Power Backup | Request a quote | |
4.3.6 | PMX-PR9000-LV | Low Voltage Modular power supply, EU type |
189,00 € (ohne MwSt) |
|
4.3.6 | DR-4524 | 45W DIN-Rail 24VDC 1.87A, 100..240VAC input |
65,00 € (ohne MwSt) |
|
4.3.6 | DRP048V480W1BN | DIN Rail Power Supply, 480W @ 48 VDC output |
239,00 € (ohne MwSt) |
|
4.3.6 | DRP024V480W1BN | DIN Rail Power Supply, 480W @ 24 VDC output |
280,00 € (ohne MwSt) |
|
4.3.6 | DRP024V240W1BN | DIN Rail Power Supply, 240W @ 24 VDC output |
190,00 € (ohne MwSt) |
|
4.3.6 | DRP048V120W1BN | DIN Rail Power Supply, 120W @ 48 VDC output |
119,00 € (ohne MwSt) |
|
4.3.6 | DRP024V120W1BN | DIN Rail Power Supply, 120W @ 24 VDC output |
120,00 € (ohne MwSt) |
|
4.3.6 | DRP048V060W1BN | DIN Rail Power Supply, 60W @ 48 VDC output |
79,00 € (ohne MwSt) |
|
4.3.6 | DRP024V060W1BN | DIN Rail Power Supply, 60W @ 24 VDC output |
78,00 € (ohne MwSt) |
|
4.3.6 | PME-PR9000-HV-EU | High Voltage Modular power supply, EU type | Request a quote | |
4.3.6 | PMA-PR9000-HV-US | High Voltage Modular power supply, US type | Request a quote | |
4.3.6 | PAE-502400-EU | 50VDC 2,4A 120W 100 to 240VAC input. EU power cord | Request a quote | |
4.3.6 | PAA-502400-US | 50VDC 2,4A 120W 100 to 240VAC input. US power cord | Request a quote | |
4.3.6 | PAX-482500 | 48VDC 2,5A 120W 100..240VAC input, no cord | Request a quote | |
4.3.6 | PAE-482500-EU | 48VDC 2,5A 120W 100..240VAC input, EU plug | Request a quote | |
4.3.6 | PAA-482500-US | 48VDC 2,5A 120W 100..240VAC input, US plug | Request a quote | |
4.3.6 | PAE-121000-EU | 12VDC 1A 12W 100..240VAC input, EU plug | Request a quote | |
4.3.6 | PAA-121000-US | 12VDC 1A 12W 100..240VAC input, US plug | Request a quote |
Hier gibt es derzeit keine Kategorien.
acceed News

Die Nuvo-11000-Serie ist Neousys’ robustes Embedded-Flaggschiff, basierend auf Intel® Core™ Ultra 200 Prozessoren mit bis zu 24 Kernen/Threads, DDR5-6400-Speicher, PCIe Gen5 und integrierter NPU für bis zu 36 TOPs KI-Leistung. Sie bietet 1,2-fache CPU-Performance bei besserer Energieeffizienz und eignet sich für anspruchsvolle Industrieanwendungen. Zur Ausstattung gehören fünf 2,5GbE- und ein 1GbE-Port (optional PoE+), ein optionaler 10GbE-Port, acht USB 3.2 Gen2-Ports sowie ein M.2 Gen5x4-Slot mit SSD-Transferraten über 11.000 MB/s. Erweiterungen über Cassette, MezIO® und Mini-PCIe sowie isolierte DI/DO sorgen für flexible Anpassungen, hohe Konnektivität und zuverlässigen Betrieb in rauen Umgebungen.

Die multifunktionalen DAQ-Karten PCIe-9146 und PCIe-9147 sind leistungsstarke Neuentwicklungen, die eine präzise und hochflexible Datenerfassung in anspruchsvollen Anwendungen ermöglichen. Diese PCIe-Karten kombinieren simultane Datenerfassung auf mehreren Kanälen mit Geschwindigkeit und Präzision. Damit sind sie für den allgemeinen Einsatz in der professionellen Messtechnik ebenso geeignet wie für Aufgaben in der industriellen Automatisierung oder in der Forschung und Entwicklung. Dank ihrer Fähigkeit, mehrere Signale gleichzeitig zu erfassen, bieten sie eine optimale Lösung für Anwendungen, bei denen Synchronität und hohe Auflösung von entscheidender Bedeutung sind, zum Beispiel bei der Schwingungserfassung.

Edge-KI-Anwendungen bedeuten für die eingesetzte Hardware oft eine Unterbringung in knapp bemessenen Gehäusen, Kanälen oder engen Boxen. Zum Schutz vor Umwelteinflüssen sind Einhausungen unvermeidlich, aber ebenso unvermeidlich leidet die Luftzirkulation und damit die Kühlung. Mit einem neuen lüfterlosen Chassis-Design für die Installation in engen Räumen mit reduziertem Luftstrom bei gleichzeitigem Betrieb mit hohem Umgebungstemperaturen punktet jetzt der KI-Controller NRU-156U3-FT von Acceed. Der vollflächig aufliegende, flache Kühlkörper maximiert die Kühleffizienz über die gesamte Gehäuseoberseite und ermöglicht so eine effiziente Wärmeableitung auch bei reduzierter Luftzirkulation. Der robuste Embedded-PC besitzt sechs USB-Schnittstellen (3.2) und ist für den Betrieb bei Umgebungstemperaturen von -25 bis +60 °C vorgesehen.

Gute Kühlung, oder präziser ausgedrückt effektive Wärmeableitung, ist ein nicht unwesentlicher Faktor, wenn es um Betriebssicherheit und Leistung bei eingebauten Computern, den für industrielle Anwendungen gefragten Embedded-Controllern geht. Traditionell setzt man hier auf ausladende Rippenkühlkörper, die auf das eigentliche Gehäuse montiert sind. Einen anderen Weg beschreitet der erfahrene Hersteller Neousys mit seiner neuen Modellserie Nuvo-9531-FT, die bei Acceed erhältlich ist.

Die erfolgreiche NRU-Serie für Edge-KI-Anwendungen beim deutschen Distributor Acceed erhält Zuwachs der besonderen Art. Das auch bisher schon lüfterlose Chassis-Design für den Betrieb bei hohen Temperaturen wurde durch eine außergewöhnliche Neugestaltung noch einmal optimiert. Der jetzt vollflächig aufliegende, flache Kühlkörper maximiert die Kühleffizienz über die gesamte Gehäuseoberseite und ermöglicht so den Einsatz des Controllers in geschlossenen Gehäusen oder engen Räumen mit reduziertem Luftstrom. Der robuste NRU-154PoE-FT besitzt vier GbE-Schnittstellen (2,5 Gb) mit PoE und ist für den Betrieb bei Umgebungstemperaturen von -25 bis +60 °C vorgesehen.