AD12-64(PCI)

PCI AD card 100kS/s 12 Bit 64 channels + 4*DI + 4*DO
490,00 EUR

including VAT 583.10 EUR

  • Manufacturer Contec
  • Category: A/D General Purpose PCI
  • The CONTEC AD12‑64(PCI) is a high‑performance PCI‑compliant analog input interface board designed for multi‑channel data acquisition applications. It provides up to 64 single‑ended or 32 differential analog input channels with 12‑bit resolution and a maximum sampling rate of 100 kS/s per channel. The board also includes four digital input and four digital output channels, a programmable timer, and external trigger and sampling clock inputs. It is compatible with both Windows and Linux environments and supports LabVIEW integration through the VI‑DAQ library.
- High‑Density Multi‑Channel Analog Input:
Supports 64 single‑ended or 32 differential analog input channels. Channel configuration (single‑ended/differential) is software‑selectable.

- Flexible Input Range Configuration:
Each channel’s input range can be independently set via software to one of eight ranges:
±10 V, ±5 V, ±2.5 V, ±1.25 V, 0–10 V, 0–5 V, 0–2.5 V, or 0–1.25 V.

- High‑Speed 12‑Bit A/D Conversion:
Conversion speed up to 10 µs per channel (100 kS/s) with 12‑bit resolution.

- Programmable Sampling Control:
Sampling can be triggered by software, internal clock, or external TTL‑level clock input. Supports both periodic and event‑driven sampling.

- Integrated Digital I/O:
Four TTL‑level digital input and four TTL‑level digital output channels for external device control and monitoring.

- Programmable Timer Function:
Timer period configurable from 500 ns to 1,073,741,824,000 ns in 250 ns increments. Provides TTL‑level output pulses for synchronization.

- External Trigger and Clock Inputs:
One non‑isolated TTL‑level external trigger input (falling edge) and one external sampling clock input for precise timing control.

- Software Support:
Includes driver libraries for Windows (API‑AIO(WDM), API‑AIO(98/PC)) and Linux (API‑AIO(LNX)), plus LabVIEW VI‑DAQ library for graphical programming.

- PCI Bus Compatibility:
32‑bit, 33 MHz PCI interface with universal keying (supports both 3.3 V and 5 V slots).

- Compact and Lightweight Design:
Dimensions 176.41 mm (L) × 105.68 mm (H); weight approximately 150 g.

- Regulatory Compliance:
Certified for VCCI Class A and CE Marking (EMC Directive Class A).

Country of origin: Japan

Customs tariff number: 8473 3020 000

Comprehensive Product Summary – AD12‑64(PCI) PCI Analog‑to‑Digital Input Board




### 1. Product Overview

Product Name: Multi‑Channel Analog Input Board
Model: AD12‑64(PCI)
Series: PCI Analog‑to‑Digital (A/D) Conversion Interface Boards
Article Number: AD12‑64(PCI)
Manufacturer: CONTEC CO., LTD. (Osaka, Japan)
Product Type: PCI Bus Analog Input (A/D) Board
Version: Ver. 3.14

The CONTEC AD12‑64(PCI) is a high‑performance PCI‑compliant analog input interface board designed for multi‑channel data acquisition applications. It provides up to 64 single‑ended or 32 differential analog input channels with 12‑bit resolution and a maximum sampling rate of 100 kS/s per channel. The board also includes four digital input and four digital output channels, a programmable timer, and external trigger and sampling clock inputs. It is compatible with both Windows and Linux environments and supports LabVIEW integration through the VI‑DAQ library.




### 2. Key Features

- High‑Density Multi‑Channel Analog Input:
Supports 64 single‑ended or 32 differential analog input channels. Channel configuration (single‑ended/differential) is software‑selectable.

- Flexible Input Range Configuration:
Each channel’s input range can be independently set via software to one of eight ranges:
±10 V, ±5 V, ±2.5 V, ±1.25 V, 0–10 V, 0–5 V, 0–2.5 V, or 0–1.25 V.

- High‑Speed 12‑Bit A/D Conversion:
Conversion speed up to 10 µs per channel (100 kS/s) with 12‑bit resolution.

- Programmable Sampling Control:
Sampling can be triggered by software, internal clock, or external TTL‑level clock input. Supports both periodic and event‑driven sampling.

- Integrated Digital I/O:
Four TTL‑level digital input and four TTL‑level digital output channels for external device control and monitoring.

- Programmable Timer Function:
Timer period configurable from 500 ns to 1,073,741,824,000 ns in 250 ns increments. Provides TTL‑level output pulses for synchronization.

- External Trigger and Clock Inputs:
One non‑isolated TTL‑level external trigger input (falling edge) and one external sampling clock input for precise timing control.

- Software Support:
Includes driver libraries for Windows (API‑AIO(WDM), API‑AIO(98/PC)) and Linux (API‑AIO(LNX)), plus LabVIEW VI‑DAQ library for graphical programming.

- PCI Bus Compatibility:
32‑bit, 33 MHz PCI interface with universal keying (supports both 3.3 V and 5 V slots).

- Compact and Lightweight Design:
Dimensions 176.41 mm (L) × 105.68 mm (H); weight approximately 150 g.

- Regulatory Compliance:
Certified for VCCI Class A and CE Marking (EMC Directive Class A).




### 3. Technical Specifications

| Parameter | Specification |
|----------------|------------------|
| Analog Input Type | Single‑ended or differential (software‑selectable) |
| Number of Channels | 64 (SE) / 32 (Diff) |
| Input Range (software‑selectable) | Bipolar: ±10 V, ±5 V, ±2.5 V, ±1.25 V; Unipolar: 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V |
| Absolute Maximum Input Voltage | ±15 V |
| Input Impedance | ≥ 1 MΩ |
| Resolution | 12 bits (4096 quantization levels) |
| Non‑Linearity Error | ±2 LSB (±10 V, ±5 V, 0–10 V, 0–5 V); ±4 LSB (±2.5 V, ±1.25 V, 0–2.5 V); ±8 LSB (0–1.25 V) |
| Conversion Speed | 10 µs per channel (100 kS/s max) |
| Sampling Clock | Internal: 10,000 – 1,073,741,824,000 ns (settable in 250 ns steps); External: TTL‑level falling edge |
| Digital I/O | 4 × TTL inputs, 4 × TTL outputs |
| Timer Output | TTL‑level 250 ns low pulse; IOL = 24 mA |
| External Trigger Input | 1 × TTL‑level (falling edge) |
| Operating Temperature | 0 – 50 °C |
| Operating Humidity | 10 – 90 % RH (non‑condensing) |
| Power Consumption | +5 V DC 700 mA (max) |
| Bus Interface | PCI 32‑bit, 33 MHz, Universal keying |
| Connector | 96‑pin half‑pitch male (PCR‑E96LMD+ or equivalent) |
| Dimensions | 176.41 mm (L) × 105.68 mm (H) |
| Weight | Approx. 150 g |
| Compliance | VCCI Class A, CE Marking (EMC Directive Class A) |

*Note:* Linearity error may increase (~0.1 % FS) at 0 °C or 50 °C; calibration under actual conditions is recommended.




### 4. Functionality

Analog Input Operation:
The AD12‑64(PCI) performs analog‑to‑digital conversion of voltage signals into 12‑bit digital data. Each channel’s range and mode (single‑ended/differential) are software‑configurable. Sampling can be continuous or event‑triggered, with data stored in FIFO or ring buffer memory structures.

Sampling Control:
- Internal Clock Mode: Uses onboard clock generator for periodic sampling.
- External Clock Mode: Synchronizes sampling to an external TTL‑level clock input.
- Software Control: Allows manual or programmatic sampling initiation.

Triggering:
Sampling can start via software command, external trigger input, or analog level comparison. Stop conditions include sample count completion, external trigger, or software abort.

Digital I/O:
Four TTL‑level inputs and four TTL‑level outputs enable external device control, status monitoring, or synchronization with other systems.

Timer Function:
Programmable timer generates periodic TTL pulses for timing or synchronization tasks. Period adjustable from 500 ns to over 1 s in 250 ns increments.

Use Cases & Applications:
- Industrial process monitoring and control
- Laboratory instrumentation and test automation
- Data logging and signal analysis
- Sensor array acquisition (temperature, pressure, vibration)
- Embedded system development requiring multi‑channel analog input

Compatibility:
- Operating Systems: Windows 7/8/10/11, Windows Server 2003–2019, Linux kernel 2.6+
- Software Environments: Visual C++, Visual Basic, Delphi, C++ Builder, gcc, LabVIEW
- Driver Libraries: API‑AIO(WDM), API‑AIO(98/PC), API‑AIO(LNX)
- LabVIEW Integration: VI‑DAQ library (free download from CONTEC website)




### 5. Components & Accessories

Standard Package Contents:
1. AD12‑64(PCI) board
2. First Step Guide
3. Driver Library Disk [API‑PAC(W32)]
4. Product Registration Card & Warranty Certificate
5. Serial Number Label

Optional Cables:
- Shielded Cable (both ends 96‑pin): PCB96PS‑0.5P (0.5 m), PCB96PS‑1.5P (1.5 m)
- Flat Cable (both ends 96‑pin): PCB96P‑1.5 (1.5 m)
- Shielded Cable (one end 96‑pin): PCA96PS‑0.5P (0.5 m), PCA96PS‑1.5P (1.5 m)
- Flat Cable (one end 96‑pin): PCA96P‑1.5 (1.5 m)

Optional Terminal Units:
- DTP‑64A (M3 × 96P)
- EPD‑96 (M3.5 × 96P)
- EPD‑96A (M3 × 96P, spring‑up type)

*Note:* Optional cables (PCB96P‑* or PCB96PS‑*) are required for terminal unit connection.




### 6. Installation & Setup

Hardware Installation Steps:
1. Software Installation:
Install the API‑PAC(W32) driver library before inserting the board.
2. Board Configuration:
Set the board ID (0–Fh) using rotary switch SW1 if multiple boards are installed.
3. Physical Installation:
Power off the PC, insert the board into a PCI slot (supports both 3.3 V and 5 V slots), and secure with a screw.
4. Driver Setup:
Upon reboot, Windows detects the board. Specify the INF file from the CD‑ROM (e.g., \INF\WDM\AIO).
5. Device Initialization:
Assign a device name via Device Manager (Windows) or API‑TOOL Configuration utility.
6. Verification:
Use the bundled Diagnosis Program to verify analog and digital I/O operation.

Environmental Requirements:
- Temperature: 0 – 50 °C
- Humidity: 10 – 90 % RH (non‑condensing)
- No corrosive gases or excessive dust

Mounting:
Standard PCI slot installation; ensure adequate airflow and grounding.




### 7. Performance & Capabilities

- Sampling Rate: Up to 100 kS/s per channel
- Resolution: 12 bits (0.00244 V per step at 0–10 V range)
- Input Impedance: ≥ 1 MΩ
- Accuracy: ±2 LSB typical (±10 V range)
- Timer Resolution: 250 ns
- Digital Output Drive: 24 mA sink current per channel
- External Trigger Response: TTL falling edge detection (~200 ns delay)
- Data Buffering: FIFO or ring memory modes
- Latency: < 10 µs conversion delay per channel
- Power Draw: +5 V DC 700 mA (max)

Limitations:
- Non‑isolated analog inputs (requires proper grounding)
- Operates only with +5 V PCI bus power (not 3.3 V only systems)
- Cross‑talk may occur with > 1 MHz input signals
- Input voltage must not exceed ±15 V relative to analog ground




### 8. Standards & Compliance

- Bus Interface: PCI 32‑bit, 33 MHz, Universal keying
- Electrical Safety: Non‑isolated inputs and I/O (ensure proper grounding)
- EMC Compliance: VCCI Class A, CE Marking (EMC Directive Class A)
- Environmental: RoHS compliant (manufacturer standard)
- Operating Conditions: 0–50 °C, 10–90 % RH (non‑condensing)
- Calibration: Factory‑calibrated; recalibration recommended under actual operating temperature conditions.




### 9. Additional Information

Software Support:
- Windows Drivers: API‑AIO(WDM) and API‑AIO(98/PC) with sample programs for Visual Basic, Visual C++, Delphi, and C++ Builder.
- Linux Drivers: API‑AIO(LNX) (shared library and kernel module) with gcc sample programs.
- LabVIEW Integration: VI‑DAQ library for LabVIEW provides ready‑to‑use VIs for data acquisition.
- Diagnostic Tools: Built‑in Diagnosis Program for hardware verification and performance testing.

Maintenance & Calibration:
- Periodic inspection recommended to ensure connector cleanliness and secure seating.
- Calibrate if accuracy drifts due to temperature or aging.
- Clean PCI edge contacts with industrial alcohol if handled directly.

Warranty & Support:
- Warranty Period: Three years from date of purchase.
- Coverage: Defects in materials and workmanship (excludes wear and misuse).
- Service Procedure: Return with RMA number and proof of purchase to authorized CONTEC distributor.
- Support Resources: https://www.contec.com/ for drivers, manuals, and technical updates.

Safety Precautions:
- Do not install or remove the board while the PC is powered on.
- Avoid exposure to flammable or corrosive gases.
- Ensure adequate power supply capacity for all installed boards.
- Use shielded cables to maintain EMC compliance.

Board Variants (Dimensional Differences):
| Board No. | Dimensions (mm) | Notes |
|----------------|---------------------|-----------|
| 7149A | 176.41 × 106.68 | PCI 5 V bus version |
| 7149B | 176.41 × 106.68 | Universal key version |
| 7149D | 176.41 × 105.68 | Latest revision (Ver. 3.14) |




### Summary

The CONTEC AD12‑64(PCI) is a robust, high‑channel‑count analog input board engineered for precision data acquisition in industrial and laboratory environments. With 64 single‑ended or 32 differential inputs, 12‑bit resolution, and 100 kS/s sampling speed, it offers a balance of performance and flexibility. Its software‑configurable input ranges, programmable timer, and digital I/O expand its utility for automation, measurement, and control applications. Comprehensive driver support for Windows, Linux, and LabVIEW ensures seamless integration into existing systems. Certified for VCCI and CE standards, the AD12‑64(PCI) delivers industrial‑grade reliability and precision in a compact PCI form factor.
  • DTP-64A - unversal screw terminal with HD D-sub 96f
  • EPD-96 - DIN-rail termination panel with HD D-sub 96f
  • PCB96PS-0.5P - Cable 0,5m shielded with 96pin connector at each end
  • PCB96PS-1.5P - Cable 1,5m shielded with 96pin connector at each end
  • PCB96PS-3P - Cable 3m shielded with 96pin at each end
  • PCB96PS-5P - Cable 5m shielded with 96pin at each end
  • PCB96WS-1.5 - Cable 1,5m shielded with 96pin to 2*37pin D-type male
  • PCB96WS-3 - Cable 3m shielded with 96pin to 2*37pin D-type male
  • PCB96WS-5 - Cable 5m shielded with 96pin to 2*37pin D-type male
  • DTP-3C - General purpose screw terminal panel, 2*22 large screw
  • DTP-4C - General purpose M2.5 screw terminal panel, 4*10 screw blocks
  • EPD-37A - DIN-rail mountable unit with DB-37f